![AIRLESSCO 24E365 600 Series Operation - Repair - Parts Download Page 8](http://html1.mh-extra.com/html/airlessco/24e365-600-series/24e365-600-series_operation-repair-parts_2877319008.webp)
Operation
8
3A0413B
Operation
Pressure Relief Procedure
Follow the
Pressure Relief
Procedure
whenever you see this
symbol.
1.
Turn sprayer
OFF
.
2.
Engage the trigger lock. Always engage
the trigger lock when sprayer is stopped
to prevent the gun from being triggered
accidentally.
3.
Turn pressure control knob to lowest
setting.
4.
Put drain tube into a waste pail and turn
Prime/Spray valve in PRIME position
(drain) to relieve pressure.
5.
Hold the gun firmly to a pail. Point gun
into pail. Disengage the trigger lock and
trigger the gun to relieve pressure.
6.
Engage the trigger lock.
7.
If you suspect the spray tip or hose is
clogged or that pressure has not been
fully relieved:
a.
VERY SLOWLY loosen the tip
guard retaining nut or the hose end
coupling to relieve pressure
gradually.
b.
Loosen the nut or coupling
completely.
c.
Clear the obstruction in the hose or
tip.
Gun Trigger Lock
This equipment stays pressurized until
pressure is manually relieved. To help
prevent serious injury from pressurized
fluid, such as skin injection or splashed
fluid, follow the
Pressure Relief
Procedure
whenever sprayer is stopped
and before sprayer is cleaned or checked,
and before equipment is serviced.
To prevent injury when the gun is not in
use, always engage the gun's trigger lock if
unit is being shut down or left unattended.