www.airkinglimited.com

6728092 Rev. E 4/22

1 of 12

SAVE THESE INSTRUCTIONS

WARNING:

 TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK AND INJURY TO PERSON, 

OBSERVE THE FOLLOWING: 

a)  Use this unit only in the manner intended by the manufacturer. If you have 

questions, contact the manufacturer.

b)  Before servicing or cleaning the unit, switch power off at service panel 

and lock the service disconnecting means to prevent power from being 

switched on accidentally. When the service disconnecting means cannot 

be locked, securely fasten a prominent warning device, such as a tag, to 

the service panel.

WARNING:

 TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK AND INJURY TO PERSON, 

OBSERVE THE FOLLOWING: 

a)  Installation work and electrical wiring must be done by qualified person(s) 

in accordance with all applicable codes and standards, including fire-

related construction.

b)  Sufficient air is needed for proper combustion and exhausting of gases 

through the flue (chimney) of fuel burning equipment to prevent back 

drafting. Follow the heating equipment manufacturer’s guideline and 

safety standards such as those published by the National Fire Protection 

Association (NFPA) and the American Society for Heating, Refrigeration, 

and Air Conditioning Engineers (ASHRAE), and the local code authorities.

c)  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

CAUTION:

 

FOR GENERAL VENTILATING USE ONLY. 

DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE 

MATERIALS AND VAPORS.

d)  This unit must be grounded.
e)  To avoid motor bearing damage and noisy and/or unbalanced impellers, 

keep drywall spray, construction dust, etc. off power unit.

f)  Read all instructions before installing or using exhaust fan.
g)  For residential installations only.
h)  Must use suitable weather hood with insect screen to protect air intake.

WARNING:

 TO REDUCE THE RISK OF FIRE, 

REMOVE ANY SHIPPING MATERIAL THAT MAY BE 

PRESENT INSIDE THE UNIT.

WARNING:

 TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY 

SOLID-STATE SPEED CONTROL DEVICE.

WARNING:

 DO NOT USE IN KITCHENS.

WARNING: 

THE DUCTING FROM THIS FAN TO THE 

OUTSIDE OF THE BUILDING HAS A STRONG EFFECT ON THE 

AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE THE SHORTEST, 

STRAIGHTEST DUCT ROUTING POSSIBLE FOR BEST PERFORMANCE, 

AND AVOID INSTALLING THE FAN WITH SMALLER DUCTS THAN 

RECOMMENDED. INSULATION AROUND THE DUCTS CAN REDUCE 

ENERGY LOSS AND INHIBIT MOLD GROWTH. FANS INSTALLED WITH 

EXISTING DUCTS MAY NOT ACHIEVE THEIR RATED AIRFLOW.

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN 

THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 

INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL 

INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions should 

always be followed to reduce the risk of fire, electric shock and 

injury to person, including the following:

Inline Fan

MQFAM, MFAS

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Summary of Contents for MFAS

Page 1: ... EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS d This unit must be grounded e To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit f Read all instructions before installing or using exhaust fan g For residential installations only h Must use suitable weather hood with insect screen to protect air intake WARNING TO REDUCE ...

Page 2: ...e the shortest straightest duct routing possible for best performance and avoid installing the fan with smaller ducts than recommended Insulation around the ducts can reduce energy loss and inhibit mold growth Fans installed with existing ducts may not achieve their rated air flow WARNING MAKE SURE THE FRESH AIR INTAKE PORT COMPLIES WITH ALL LOCAL AND NATIONAL CODES AND IS LOCATED AT LEAST 6 FEET ...

Page 3: ...ch 50 80 Figure 8 Figure 9 Filter Screw Air Flow NOTE This unit is equipped with a wire mesh insect screen Confirm that the screen is installed on the inside of the unit on the inlet ducting side 1 If the screen is not in place insert the screen into the tab at the base of the unit make sure the wider side of the screen is running side to side inside the unit Figure 10 2 Slide the screen to the si...

Page 4: ...mperature setpoint adjustment range 32 F 55 F 0 C 10 C High temperature setpoint adjustment range 65 F 95 F 18 C 35 C Default humidity setpoint range 30 Low 65 High Low humidity setpoint adjustment range 10 50 High humidity setpoint adjustment range 55 80 SECTION 10 Optional Motorized Damper An optional model MD624 Motorized Damper sold separately can be added to the unit When connected to the MQF...

Page 5: ...THE PRODUCT WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACEMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURC...

Page 6: ...6 Metal Collar Intake 5S1650030 3 1 6 Metal Collar Outlet 5S1650029 4 1 Blower Assembly 5S1650031 5 1 Wire Compartment Assembly 5S1650032 6 1 LCD Controller MQFAM 5S1650043 7 1 Insect Screen 5S1650028 8 1 Harness 5S1650033 9 1 Access Panel 5S1650042 REPLACEMENT PARTS DIAGRAM 3 1 1 4 2 5 6 7 8 9 REPLACEMENT PARTS DIAGRAM ...

Page 7: ... b Avant d effectuer un service ou de nettoyer l unité couper l alimentation électrique dans le panneau de distribution et verrouiller le dispositif de déconnexionafind éviterquel alimentationnerevienneaccidentellement Lorsque le dispositif ne peut être verrouillé fixer solidement un avis d avertissement tel qu une étiquette au panneau de distribution AVERTISSEMENT POUR RÉDUIRE LES RISQUES D INCEN...

Page 8: ...ible pour une meilleure performance et évitez d installer le ventilateur avec des conduits plus petits que recommandé L isolation autour des conduits peut réduire la perte d énergie et empêcher le développement de moisissures Il se peut que les ventilateurs installés avec des conduits existants n atteignent pas leur débit d air nominal AVERTISSEMENT ASSUREZ VOUS QUE LE PORT D ADMISSION D AIR FRAIS...

Page 9: ...res REMARQUE Cette unité est équipée d un grillage pour moustiquaire Assurez vous que le grillage est installé à l intérieur de l unité du côté des conduits d entrée 1 Si le grillage n est pas en place insérez le grillage dans la languette située à la base de l unité assurez vous que le côté le plus large du grillage est latéral à l intérieur de l unité Figure 10 2 Faites glisser le grillage sur l...

Page 10: ...0 bas 65 élevé Portée d ajustement de l humidité basse 10 50 Portée d ajustement de l humidité élevée 55 80 SECTION 10 Amortisseur motorisé optionnel Un amortisseur motorisé optionnel MD624 vendu séparément peut être ajouté à l unité Lorsqu il est connecté au MQFAM l amortisseur motorisé s ouvre lorsque le MQFAM est activé et se ferme lorsque le MQFAM s éteint Le MD624 requiert également une boîte...

Page 11: ...UME AUCUNE RESPONSABILITÉ EXPRESSE OU TACITE POUR I DES DOMMAGES ACCIDENTELS OU INDIRECTS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA RÉPARATION DE TOUS FUSIBLES DISJONCTEURS OU RÉCEPTACLES DE MAISON MALGRÉ N IMPORTE QUOI À L EFFET CONTRAIRE DANS AUCUN CAS LA RESPONSABILITÉ D AIR KING SOUS UNE GARANTIE EXPRESSE OU TACITE NE DÉPASSERA LE PRIX D ACHAT DU PRODUIT ET UNE TELLE RESPONSABILITÉ ...

Page 12: ...de 6 po d admission 5S1650030 3 1 Assemblée de collier en métal de 6 po sortie 5S1650029 4 1 Assemblée de la Soufflante 5S1650031 5 1 Assemblée du compartiment du fil 5S1650032 6 1 Contrôleur LCD MQAMF 5S1650043 7 1 Écran pour les insectes 5S1650028 8 1 Harnais 5S1650033 9 1 Panneau d accès 5S1650042 3 1 1 4 2 5 6 7 8 9 DIAGRAMME DES PIÈCES DE REMPLACEMENT ...

Reviews: