Airgroup ARENA 2 ZONE User Instructions Download Page 6

 

 

 

 

 

SYSTEM FEATURES 

2 ZONE 

 

Watchdog 

 

There is a watchdog circuit to watch the operation of the microprocessor. If it has malfunctioned, this circuit will reset the 

microprocessor automatically. 

 

Compressor delay protection 

 

Each time the compressor is off, there will always be a 3 minute time delay before the compressor can restart. In case of 

power interruption, the system will delay the operation of the compressor in the range of 3-4 minutes in random order. This is 

to 

prevent more than one compressor starting at the same time as another, saving the powerboard from „overloading‟

.

 

 

Compressor minimum on time 

 

Once the compressor starts, it will operate at least 24 seconds. 

 

Non-volatile memory 

 

The system keeps the setting parameters such as on/off status, fan speed, etc. in its non-volatile memory. If there is a power 

interruption and back to normal, the control will automatically resume its operation with the same setting parameters  

(except the sleep and timer function which will be cancelled.) 

 

If there is any change in the parameter, it will be saved in the non-volatile memory 5 seconds later. 

 

Freeze (Anti-ice) function 

 

In COOL or DRY mode, there is a feature to prevent the evaporator from freezing. 

 

Enter into Freeze process 

While in Freeze process 

Exit from Freeze process 

T

indoor

 coil < 0

o

C, and 

Comp. stops, and 

T

indoor

 coil > 7

o

C, or 

Comp. runs continuously more than 10 min. 

Indoor fan at low speed, and 

System OFF 

 

There will be an alarm signal at the 

Display unit. 

 

 

 

 

Summary of Contents for ARENA 2 ZONE

Page 1: ...ONTROLLER USER INSTRUCTIONS 2 ZONE 4 ZONE 28 30 Division Street WELSHPOOL WA 6106 Phone 08 9350 2200 Fax 08 9353 4225 ABN 68 547 176 720 Westbury Holdings Pty Ltd As trustee for the W H Unit Trust inc...

Page 2: ...tion 2 ZONE 7 Heat Fail 2 ZONE 8 Error Display 8 CONCLUSION OF FEATURES 8 INTRODUCTION 4 ZONE 9 USER S FEATURES 4 ZONE 10 Power On Off 10 Fan speed 10 Operating mode 10 Temperature Setting 10 Zone con...

Page 3: ...ce is 1 C or less the speed is low Note The button cannot be used in DRY mode Zone Control ZONE buttons are used to turn on off the damper Jumper at OP5 is for selection of the following algorithm a J...

Page 4: ...play unit When any one of the sensors have failed short open circuit the temperature will be read from another sensor Fan The system will operate as Fan only The SLEEP TEMP and TEMP buttons are not us...

Page 5: ...n to set the time Press START button again to confirm To cancel this function press START button again Timer off The air conditioner can be programmed to turn off in advance Press STOP button stop tim...

Page 6: ...s it will operate at least 24 seconds Non volatile memory The system keeps the setting parameters such as on off status fan speed etc in its non volatile memory If there is a power interruption and ba...

Page 7: ...8 o C line AB during 30 60 minutes and remains at 8 o C or below more than 5 minutes The outdoor coil temperature is reduced from 3 to 4 o C line AC during 60 120 minutes and remains at 4 o C or below...

Page 8: ...blinks with signal as per Fig A Freeze or Defrost function is activated Zone 1 LED blinks with signal as per Fig B Cooling or Heating fail function is activated Timer LED blinks with signal as per Fig...

Page 9: ...ly Heat Cool versions Its application is for the duct type system which can control up to 4 zone dampers The system consists of Main unit Display unit which up to 2 units can be used External transfor...

Page 10: ...en Troom Tset T T Speed 3 o C high 2 o C medium 1 o C low Operating mode By pressing MODE button the air conditioner can be put in 3 modes fan cool dry if the COOL version is ordered 5 operating modes...

Page 11: ...the MINUTE setting and then press or button to set Note To cancel is by pressing POWER button while in this setting mode Timer off Move cursor to OFF position and then press MENU button Press or butto...

Page 12: ...if Tindoor coil 7 o C or the system is turned off Defrost function In HEAT mode if Toutdoor coil is very low the compressor cannot operate efficiently This function will be activated to protect the c...

Page 13: ...he average value of two readings or b From the last Display unit which the button is pressed This option can be selected by Jumper OP4 on Main unit Offset temperature In heat mode the offset for room...

Page 14: ...but does not cool enough Check if the preset temperature is too high Check if the sunlight shines directly into the room Check if the door and the window are opened Check if there is anything obstruc...

Reviews: