Zone control 

 

4 ZONE

 

To turn On/Off the zone dampers: 

  Press & hold MENU button for 2 seconds, Display shows ZONE. 

  Press A, B, C or D button(s) to turn on/off any particular zone(s), Display shows the active zone(s). 

Note: 

To exit press the MENU button again or if no button is pressed exit occurs within 15 seconds. 

 

Enhanced features 

Following is an enhanced features instruction that the user has to enter into Menu window. 

Enter into Menu 

  Press MENU button to display the menu. Using 

 or 

 button to move the cursor. 

Clock setting 

  Move cursor to 

 

position and then press MENU button. 

  Press 

 or 

 button for Hour setting. 

  Use 

 or 

 button to enter the Minute setting and then press 

 or 

 button for setting. 

  Use 

 to enter the Day setting and then press 

 or 

button for setting. 

Note:

 If Timer on/off is set, there will be no Clock display. 

Timer on 

  Move cursor to 

ON

 

 

position and then press MENU button. 

  Press 

 or 

button for HOUR setting. 

  Use 

 or 

 button to enter the MINUTE setting and then press 

 or 

 button to set. 

Note:

 To cancel is by pressing POWER button while in this setting mode. 

Timer off 

  Move cursor to 

OFF

 

 

position and then press MENU button. 

  Press 

 or 

 button for HOUR setting. 

  Use 

 or 

 button to enter the Minute setting and then press 

 or 

 button to set. 

Note:

 To cancel  press POWER button while in setting mode. 

Zone control 

  Move cursor to ZONE position and then press MENU button.

 

  Press A, B, C or D button(s) to turn on/off any particular zone(s), Display shows the active zone(s).

 

7 Day program 

The system can be programmed to turn on/off 5 + 2  or 7 day basis. 

  Move cursor to 7 DAY position and then press MENU button. 

  Use 

 or 

 button to select 5, 2  or 7 day setting and then press MENU button. 

 

  Use 

 or 

 button to enter the Timer on/off, Hour/Minute setting and then press 

 or 

 button for setting. 

Note:   -

 

If 7 Day program‟s Timer on/off is set, the LCD shows “7 DAY”. 

- To cancel press the POWER button while Timer on/off  7 

Day program mode. The LCD does not show “7 

DAY”.  

- To override is by pressing 

 

button at the same time. The LCD shows “7 DAY” is blinking. 

 - To deactivate the override  press the 

 button at the same time. 

 

Summary of Contents for ARENA 2 ZONE

Page 1: ...ONTROLLER USER INSTRUCTIONS 2 ZONE 4 ZONE 28 30 Division Street WELSHPOOL WA 6106 Phone 08 9350 2200 Fax 08 9353 4225 ABN 68 547 176 720 Westbury Holdings Pty Ltd As trustee for the W H Unit Trust inc...

Page 2: ...tion 2 ZONE 7 Heat Fail 2 ZONE 8 Error Display 8 CONCLUSION OF FEATURES 8 INTRODUCTION 4 ZONE 9 USER S FEATURES 4 ZONE 10 Power On Off 10 Fan speed 10 Operating mode 10 Temperature Setting 10 Zone con...

Page 3: ...ce is 1 C or less the speed is low Note The button cannot be used in DRY mode Zone Control ZONE buttons are used to turn on off the damper Jumper at OP5 is for selection of the following algorithm a J...

Page 4: ...play unit When any one of the sensors have failed short open circuit the temperature will be read from another sensor Fan The system will operate as Fan only The SLEEP TEMP and TEMP buttons are not us...

Page 5: ...n to set the time Press START button again to confirm To cancel this function press START button again Timer off The air conditioner can be programmed to turn off in advance Press STOP button stop tim...

Page 6: ...s it will operate at least 24 seconds Non volatile memory The system keeps the setting parameters such as on off status fan speed etc in its non volatile memory If there is a power interruption and ba...

Page 7: ...8 o C line AB during 30 60 minutes and remains at 8 o C or below more than 5 minutes The outdoor coil temperature is reduced from 3 to 4 o C line AC during 60 120 minutes and remains at 4 o C or below...

Page 8: ...blinks with signal as per Fig A Freeze or Defrost function is activated Zone 1 LED blinks with signal as per Fig B Cooling or Heating fail function is activated Timer LED blinks with signal as per Fig...

Page 9: ...ly Heat Cool versions Its application is for the duct type system which can control up to 4 zone dampers The system consists of Main unit Display unit which up to 2 units can be used External transfor...

Page 10: ...en Troom Tset T T Speed 3 o C high 2 o C medium 1 o C low Operating mode By pressing MODE button the air conditioner can be put in 3 modes fan cool dry if the COOL version is ordered 5 operating modes...

Page 11: ...the MINUTE setting and then press or button to set Note To cancel is by pressing POWER button while in this setting mode Timer off Move cursor to OFF position and then press MENU button Press or butto...

Page 12: ...if Tindoor coil 7 o C or the system is turned off Defrost function In HEAT mode if Toutdoor coil is very low the compressor cannot operate efficiently This function will be activated to protect the c...

Page 13: ...he average value of two readings or b From the last Display unit which the button is pressed This option can be selected by Jumper OP4 on Main unit Offset temperature In heat mode the offset for room...

Page 14: ...but does not cool enough Check if the preset temperature is too high Check if the sunlight shines directly into the room Check if the door and the window are opened Check if there is anything obstruc...

Reviews: