Electrical connection 

All work must be carried out with the equipment fully isolated from the power supply. The electrical connection
is to be carried out in accordance with the relevant wiring diagram and are only to be done by a certified
electrician. The fans may not be operated with transformer controllers.

All relevant safety regulation, national standards and norms are to be adhered to. 

4.1

Electronic control board

PCB with automatic humidity control and timer. The control board is fitted into a splash-proof casing.  

QuietAir 100HT 

with automatic humidity control and timer

QuietAir 120HT 

with automatic humidity control and timer

EMV regulation
Important indication for the electromagnetic compatibility

Interference resistance according to DIN EN 55014-2 depending upon impulse form and energy rate of 1000 V to 
4000 V. With operation with fluorescent tubes, switch power supplies, electronically regulated halogen bulbs etc. these
values can be exceeded.
In  this case additional suppression shielding activities are necessary (L -, C or RC elements, protection diodes, 
resistors).

5.0

Cleaning and maintenance

- Before cleaning, ensure that the fan is isolated from the power supply.
- Prevent unintentional restart !
- Clean device only with a damp cloth.
- The device is maintenance-free.

5.1

Dismantling of fascia

Procedure:

1. Isolate the device from the power supply and prevent unintentional restart!
2. Remove the fascia (1) by using the correct tool (e.g. screw driver) and applying light pressure on the spring catches

left and right of the fascia (Fig.10). 

3. Unfasten the screws of the control board cover (2) (Fig.11). 

6.0

Troubleshooting

- If the thermal protection trips this could be the result of dirt  build-up, a hard running impeller and/or bearings. 

Too high winding temperature through insufficient motor cooling, or too high air flow temperature could be the cause 
of disturbance.

- Abnormal noises can mean worn out bearings.
- Vibrations can originate from an unbalanced or dirty impeller or due to the installation.
- Extreme performance reduction can occur if the fan must work against too high resistance of the ventilation system

or if there is a lack of sufficient supply air (causing also higher sound level).

5

Installation and Operation Instructions

4

Installation and Operation Instructions

WARNING  

NOTE  

CHAPTER 4

ELECTRICAL
CONNECTION

CHAPTER 5

CLEANING AND
MAINTENANCE

CHAPTER 6

TROUBLESHOOTING

Wiring diagram overview

QuietAir 100HT - 75(90)m

3

/hr

QuietAir 120HT - 150(170)m

3

/hr

SS-931

Terminal N/L:

A  permanent  supply  voltage  of  230v/1Ph/50-60  Hz  should  be
connected to terminals N and L, for ALL installations.  The unit is double
insulated and does not require an earth. (drawing SS-919)

You need an additional switched live to Terminal 1 OR/AND Terminal 2
to give your fan its functionality. 

Terminal 1 Functionality 

Factory set 2 minute delay start,15 minute timer overrun and humidity

sensor is also live and active. (drawing SS-919)

Terminal 2 Functionality

Fan performs at a second speed by way of a second switch . (drawing
SS-919)

TERMINAL 1 AND TERMINAL 2 FUNCTIONALITY

The fan functions as outlined in Terminal 1 above, when Terminal 1 timer
delay or run on timer or humidity is not activated, then a separate switch
wired to Terminal 2 enables you to use the second speed. . (drawing
SS-919)
See also  notes 1, 2 and 3 below for more detail

1.  Standard functionality out of the box with Terminal 1 ONLY used 

This option activates a 2 minute delayed start and timer overrun and
makes the humidity function live.

Delayed start 2 minutes

This energy saving function enables a short visit without the fan turning
on.  A useful facility, particularly at night.

Run on Timer

When the fan has been activated by a switch, the 15 minute run on timer
is also activated when the switch has been turned off.

Automatic Humidity Control

With a progressive increase in humidity the fan will start when the pre-
set value (factory setting 70% RH) is reached.  However, when the
sensor  detects  a  rapid  increase  in  humidity  the  fan  will  start
automatically  before  the  pre-set  value  has  been  reached  so  that
preventive ventilation commences.
The fan switches off automatically when the humidity is reduced to 10%
below the set point.
Note: It is possible that a high level of humidity is present within the room
for a longer period of time due to generally high humidity in the ambient
air  (summertime)  or  a  build  up  of  high  humidity  over  several  hours
(stream rooms/sauna etc)

2.  Standard functionality out of the box with Terminal 2 ONLY live   

Fan operates by a remote switch at the speed set in terminal 2.

3.  Standard functionality out of the box with Terminal 1 AND 2 live

This option gives you all the functionality of terminal 1 as outlined above
and the functionality of terminal 2 as outlined above. However terminal 2
only functions when none of the functions of terminal 1 are active.   

Test mode and calibration at initial start-up

When applying the supply voltage the fan is in the test mode for 1
minute (Note: Factory DIP switch settings must be in accordance with
wiring diagram SS-9

41.2

).  In this mode the delayed start and the overrun

timer functions are deactivated within the first minute.

Internal functional principle / Jumper position

Connection client

WARNING 

SS-941.2

Adjustment of DIP-switchs

S1

1 2

L

N

QT ... HT

Nachlauf  /

Einschaltz eit

- relativ e F euchtigkeit  in  %

- Schaltschwelle , Ein /  Aus

1

2

3

4

55

off
on

off

off

off

on

on

off

on

on

off

off

off

on

on

off

on

on

0 sec

2 min

6 min

12 min

15 min

21 min

70/60

90/80

80/70
60/50

DIP-Schalter

/

Switch / Commutateur

off

on

1 2 3 4 5 6

6

% rF

off

on

Zeit / % rF deaktivieren

%rF

%rF

Einschaltv erzöger ung

Dela yed star t

Démarrage tempor isé

Run on time  /

Running time

Temporisation  /

Durée de f onctionnement

- humidité relativ e en  %

- Valeur marche / arrêt

Time / % rF deactivate

- relativ e humiditiy  in  %

- switching threshold on / off

Te mps / % rF désacti ver

a) time function

b) manual on

The humidity sensor needs approximately 1 hour to calibrate itself at initial start-up (from switch
on of mains supply).  During the calibration period the fan may switch itself on, depending on
the prevailing environmental conditions.

ADDITIONAL FUNCTIONALITY 

De-activating the Humidity sensor temporarily

When a short switch on and off (minimum pulse 0.5 seconds) is supplied the humidity control
is switched off for 1 hour. 
In this mode all other settings are by-passed.  When the switch is operated again within 1 hour
the deactivation period is reset back to 1 hour.
Deactivation of humidity has no effect on the manual operation settings of terminal 2

CHANGING TERMINAL SPEEDS

The standard speed for terminal 1 is 75m³ and terminal 2 90m³. These can be changed 
around so that Terminal 1 is 90m³ and Terminal 2 is 75m³ 
Please see drawing SS-9

31

 and jumper configuration.

Jumper 1
QT100HT / 120HT 

Position A – Factory setting
K1. 1 = 75 m

3

/hr / 150 m

3

/hr,activated via timer function with humidity sensor (%RH)

K1. 2 = 90 m

3

/hr / 170 m

3

/hr manually activated by (optional) switch

Position B
K1. 1 = 90 m

3

/hr / 170 m

3

/hr, activated via timer function humidity sensor (%RH)

K1. 2 = 75 m

3

/hr / 150 m

3

/hr, manually activated by (optional) switch

Changing the factory setting

The DIP switch settings shown on wiring diagram SS-9

41.2

 can be changed to select alternative

functionality . The additional functionality are: disable 2 minute time delay, adjust the run on
time, adjust the humidity levels at which the fan is activated disable the run on timer and disable
the humidity function.

Always isolate the unit from the mains electric supply before commencing any work.

Room lighting

When connecting the fan to the light switch (terminal 1 or 2), a double-pole switch must be
used.

Wiring in parallel

IMPORTANT: Wiring in series of more than one fan is not permitted.

9041552_Model_QT_100_120HT   30/06/2010  11:28  Page 3