background image

3

PREPARATION INSTRUCTIONS

Unpacking:

 Before assembling and installing your ceiling fan, remove all parts from the shipping cartons and check them

against the parts listed here. Before discarding packaging material, be certain that all parts have been removed.

GETTING STARTED

Unpacking

Before assembling and installing your ceiling fan, remove
all parts from the shipping cartons and check them against
the parts listed here.  Before discarding packaging material,
be certain that all parts have been removed.

CAUTION: When removing the shrink wrap, be careful not to scratch the blades.

Be sure to only use genuine Airflow blades.  The blade shrink
wrap holds 5 blades of matched weight.  If more than one
fan is being installed, be sure not to mix blade sets.

FAN PREPARATION

PERMA•LOCK™ HARDWARE

DOWNROD & BALL

ASSEMBLY

ALLEN SET SCREW

1

4

-20 x 

1

4

"

(PRE-INSTALLED)

3mm

ALLEN WRENCH

Prepare for fan installation as follows:
Step 1.

 Route the wires from the motor through the canopy,

then the Perma•Lock™ downrod and ball assembly.

Step 2.

 Using the provided allen wrench, loosen the set screw

several turns to allow installation of the downrod.  Thread
the downrod into the motor coupling until it stops turning,
this will take at least four and a half full turns.

Step 3.

 Securely tighten the set screw with the provided allen

wrench to ensure safe operation of your fan.

Tip:

 The downrod has a tapered thread

that is designed to lock completely when
correctly installed.

CAUTION: Failure to fully lock in the down-
rod before securely tightening the allen set
screw may cause the fan to separate from
the downrod during normal operation!

MOTOR

COUPLING

TAPERED

THREAD

MOTOR

WIRES

GROUND

WIRE

ALLEN

SET SCREW

CANOPY

DOWNROD

BLUE

D1

WIRE

GETTING STARTED

Installing a New Ceiling Fixture Outlet Box

If you do not have an existing fixture located where you wish
to place your fan, an approved ceiling fixture outlet box must
be installed and wired.

Using Existing Ceiling Fixture Outlet Box

After turning the power OFF at its source (either circuit breaker
or fuse box), lower the old fixture and disconnect the wiring.
Check the ceiling fixture outlet box to be sure that it is
marked ‘

Approved for ceiling fan mounting

’. If it is not, a new

box must be installed.

WARNING: To reduce the risk of fire, electrical shock,
or personal injury, mount to outlet box marked
acceptable for ceiling fan support using the
mounting hardware provided with the outlet box.

Summary of Contents for LA HABRA

Page 1: ...LA HABRA OWNER S MANUAL...

Page 2: ...ted if you are unsure This fan is designed to be installed on an existing electrical outlet box The outlet box must be UL Listed for ceiling fan installations if it is not a new box must be installed...

Page 3: ...rflow fan For safety reasons the fan blades must be a minimum of 7 above the floor Do not locate the fan in a doorway or above a swinging door In any installation the tips of the blades must be at lea...

Page 4: ...f the downrod Thread the downrod into the motor coupling until it stops turning this will take at least four and a half full turns Step 3 Securely tighten the set screw with the provided allen wrench...

Page 5: ...ng bracket hold the fan body firmly and insert the ball into the bracket opening Check that no wires were pinched Rotate the fan body until the slot in the nylon ball fits into the pin opposite the br...

Page 6: ...PY HATCH INSTALLATION Step 8 Tuck the wires into the outlet box with the wire nuts pointed upwards so that the WHITE and BLACK wires are on opposite sides of the outlet box and all wires are clear of...

Page 7: ...m speed Third pull high speed Fourth pull fan OFF Direction of blade rotation is controlled by the reverse pull chain switch on the side of the switch housing FAN SPEED CONTROL PULL CHAIN SWITCH BLADE...

Page 8: ...oved from the fixture Each fan is rated for a maximum TOTAL wattage of lighting Exceeding the rated maximum allowable wattage for the fan will burn out the fan electronics module and void the warranty...

Page 9: ...R approved Solid State test method Ceiling fan airflow is measured in cubic feet per minute CFM Power use is measured in watts To maximize energy savings Choose a fan with high airflow efficiency CFM...

Page 10: ...COPYRIGHT 2002 CASABLANCA FAN COMPANY U S PATENT PENDING PRINTED IN ROC 761 CORPORATE CENTER DRIVE POMONA CA 91768 TOLL FREE 888 227 2178...

Reviews: