background image

 

Page 10 of 16 

Page 11 of 16 

Page 12 of 16 

Page 13 of 16 

Page 14 of 16 

Page 15 of 16 

Page 16 of 16 

Page 9 of 16 

UK Head-Office 

AIRFLOW DEVELOPMENTS Limited 
Aidelle House, Lancaster Road 
Cressex Business Park 
High Wycombe 
Buckinghamshire  
HP12 3QP 
United Kingdom 
 
Tel:        +44 (0) 1494 525252 
Fax :      +44 (0) 1494 461073 
Email:    [email protected] 
Web:     airflow.com 

Czech Republic 

AIRFLOW LUFTTECHNIK GmbH 
organizační složka Praha 
Hostýnská 520 
108 00 Praha 10 
Czech Republic 
 
 
 
Tel:        +42 (0) 2 7477 2230 
Fax:       +42 (0) 2 7477 2370 
Email:    [email protected] 
Web:     airflow.cz 

Germany 

AIRFLOW LUFTTECHNIK GmbH 
Postfach 1208 
D-53349 Rheinbach 
Germany 
 
 
 
 
Tel:         +49 (0) 222 69205 0 
Fax:        +49 (0) 222 69205 11 
Email:    [email protected] 
Web:     airflow.de 

Warranty  

Applicable to units installed and used in the United 
Kingdom. Airflow Developments Ltd guarantees the Aventa 
in-line for 3 YEARS from date of purchase against faulty 
material or workmanship. Warranty only covers the fan, 
not the reinstallation of this if required. In the event of any 
defective parts being found, Airflow Developments Ltd 
reserve the right to repair or at our discretion replace 
without charge provided that the unit:  
1. Has been installed and used in accordance with the 
fitting and wiring instructions supplied with each unit.  
2. Has not been connected to an unsuitable electrical  
supply.  
3. Has not been subjected to misuse, neglect or damage.  
4. Has not been modified or repaired by any person not 
authorised by Airflow Developments Ltd  
5. Has been installed in accordance with latest Building 
Regulations and IEEE wiring regulations by a recognised 
competent installer. 
Airflow Developments Ltd shall not be liable for any loss, 
injury or other consequential damage

in the event of a 

failure of the equipment or arising from, or in connection 
with, the equipment excepting only that nothing in this 
condition shall be construed as to exclude or restrict 
liability for negligence. 
 

This warranty does not in any way affect any statutory or 
other consumer rights.    

 

Maintenance 

SAFETY FIRST: ALWAYS ISOLATE THE FAN UNIT FROM THE 
POWER SUPPLY BEFORE REMOVING THE COVER.  
When installed according to these instructions the Aventa 
in-line range is completely safe. The materials used do not 
constitute a hazard.  

Cleaning 

 

The external housing of the fan can be wiped with a damp 
cloth. Do not use household cleaners containing abrasives. 

Note: 

Always isolate the fan when cleaning. Never clean 

any parts of the fan assembly by immersing in water or 
using a dishwasher.   

Warning 

This appliance can be used by children aged from 8 years 
and above and persons with reduced physical, sensory or 
mental capabilities or lack of experience and knowledge if 
they have been given supervision or instruction concerning 
use of the appliance in a safe way and understand the 
hazards involved. Children shall not play with the 
appliance. Cleaning and user maintenance shall not be 
made by children without supervision. 

Recommended Best Practice 

The Building Regulations 2010, Statutory Instrument Part 
9, paragraph 42, imposes a requirement that testing and 
reporting of mechanical ventilation performance is 
conducted in accordance with an approved procedure. 
Compliance with this requirement by an assessed and 
registered ‘Competent Person’ should follow a ‘Best 
Practice’ process and adopt air flow measurement, 
Method A – The Unconditional Method – using a suitable 
UKAS certified measuring instrument.  Generically referred 
to as a ‘Zero Pressure Air Flow Meter’ or ‘Powered Flow 
Meter’. 
Further information on this method is detailed in NHBC 
Building Regulations Guidance Note G272a 10/13 and 
BSRIA ‘A Guide to Measuring air flow rates’ document 
BG46/2015 

Installation with flexible ducting 

Where flexible ducting is used the diameter must be      
maintained with the minimum radius of a bend equal to the 
diameter of the ducting. It is good ventilation practice that 
the ducting is extended to 90% of its possible length in 
order to maintain the best possible airflow. Ensure that 
flexible duct connections are not over tightened to the fan 
outlet spigot. To maximise airflow rigid ducting should be 
used where possible. The fan and ducting should be 
installed in accordance with the requirements of the 
Domestic Ventilation Compliance Guide, part of the 
Building Regulations.  

Fan adjustment—Timer 

The fan with timer function switches on when the voltage 
is supplied to the LT or L1 terminal via an external switch.  
After the voltage to the LT or L1 terminal is disconnected  
the fan continues to run for the set overrun period, 
between 1 and 20 minutes. The timer overrun is factory 
set to 15 mins, it is adjusted by turning the potentiometer 
(

T

) clockwise to increase and anti-clockwise to decrease.  

 

T

 

increase 

decrease 

AIRFLOW DEVELOPMENTS LTD reserve the right  in the interest of continuous development to alter any or all 
specifications without prior notice. 

Reviews: