MAINTENANCE 
 

Maintenance work may be done only after the fan has been 
disconnected from the power supply. 
 
Service includes regular cleaning of the fan surface from dust 
and dirt after the fan has been disconnected from power supply.  
A soft dry brush or pressed air should be used to remove dust. 
 
The blades of rotor should be thoroughly cleaned every 6 
months. 
 
In order to do it, release the screws 3 (fig 1) and detach the grille 
2 from the case 1.  Use detergent dissolved in water to clean the 
rotor blades.  Avoid the liquid getting on the motor. 
 

STORAGE RULES 
 

The fan should be stored in manufacturer’s packaging in 
ventilated room at air temperature room +50

O

C to +40

O

C and 

relative air humidity not exceeding 80% (at T=25

O

C). 

 
Presence of acid alkali and other addressive substances vapours 
in the air is not permitted. 
 

Summary of Contents for AV200B

Page 1: ...INSTALLATION OPERATING INSTRUCTIONS AVENTA TURBO In Line Centrifugal Fans 9041425 AIRFLOW TM...

Page 2: ...nd other solid additives as well as sticky substances and fibre materials The temperature of ambient air should not be higher than the values indicated The fans are installed in horizontal and in vert...

Page 3: ...A B L E Weight kg AV100B 100 250 230 27 30 270 30 2 15 AV125B 125 250 217 27 30 270 30 2 2 AV150B 150 160 300 286 30 30 320 30 2 6 AV200B 200 340 280 30 30 354 40 4 0 AV250B 250 340 265 30 30 354 40...

Page 4: ...level dBa Ambient Temperature CO Protection AV100B 230 80 0 34 250 2820 46 25 55 IPX4 AV125B 230 79 0 34 355 2800 46 25 55 IPX4 AV150B 230 80 0 35 460 2725 46 25 55 IPX4 AV200B 230 107 0 47 780 2660...

Page 5: ...ess than 1m 2 In any fan position it is necessary to install a cap on the suction branch tube Precautions must be taken to avoid the black flow of gases into the room from the open flue of fans or oth...

Page 6: ...th not less than 3mm at all poles The fan is installed vertically or horizontally Direction of air charging is to comply with direction of arrow on the fan case To mount the fan on the wall or ceiling...

Page 7: ...alternating current power line It is good practise to provide a 3 amp fused spur isolator to isolate fan for maintenance or repair Figure 3 THE FAN IS COMPLETED WITH The complete set includes Fan 1 un...

Page 8: ...f rotor should be thoroughly cleaned every 6 months In order to do it release the screws 3 fig 1 and detach the grille 2 from the case 1 Use detergent dissolved in water to clean the rotor blades Avoi...

Page 9: ...Has not been subjected to misuse neglect or damage 4 Has not been modified or repaired by any person not authorised by Airflow Developments Ltd 5 Has been installed in accordance with Building Regula...

Reviews: