8. Allow to stand for at least 40 minutes, or more if possible.
9. Drain vinegar from Boiler.
10. Rinse Boiler with fresh water, drain and repeat until vinegar odor dissipates.
11. Loosely replace Boiler Cap and continue with normal storage procedure, as outlined in
PROPER STORAGE
section above.
Troubleshooting
PROBLEM
POSSIBLE CAUSE
SOLUTION
Unit fails to heat up. Heating
Indicator Light DOES NOT
illuminate.
Unit is not plugged in.
Plug power cord into electrical
outlet.
Household circuit breaker / ground
fault interrupter has tripped or
blown a fuse.
Reset circuit breaker / ground fault
interrupter, or replace fuse. For
assistance, contact a licensed
electrician.
Unit is damaged or otherwise in
need of repair.
Immediately cease usage and unplug
Contact manufacturer.
Unit fails to heat up. Heating
Indicator Light
DOES
illuminate. NOTE: Always allow
sufficient
time for unit to heat
up before pressing Steam
Trigger.
No water in Boiler.
Refer to FILLING BOILER procedure
to fill unit with water.
Mineral build-up in unit.
Refer to CARE & MAINTENANCE
section for details.
Unit is damaged or otherwise in
need of repair.
Immediately cease usage and
unplug. Contact manufacturer.
Steam output is weak or
intermittent.
Water level in Boiler is running low.
Refer to FILLING BOILER procedure
to refill unit with water.
Mineral build-up in unit.
Refer to CARE & MAINTENANCE
section for details.
Boiler Cap cannot be
unscrewed.
Boiler Cap has been overtightened
after previous use.
Boiler Cap should always be replaced
loosely when storing. For
assistance with a Cap that has
become stuck, contact manufacturer.
Product specifications
MODEL JSL-210
VOLTAGE 220-240VAC 50/60Hz
WATTAGE 900W
AMPERAGE
3.9A
WATER CAPACITY
6 OZ. (180 ML.)
HEATING TIME
3 MIN. (APPROXIMATE)
CONTINUOUS STEAM TIME
8 MIN. (APPROXIMATE)
UNIT WEIGHT 2.8 LBS. (1.3 KG.)
UNIT DIMENSIONS 13.3” (33.8 CM.) x 5.7” (14.4 CM.) x 8.3” (21.1 CM.)
POWER
CORD LENGTH 12.5’ (380.0 CM.)