AIRFLO AFS140 Instruction Manual Download Page 5

 
 

Connecting extension hose 

1. Align female end of Extension Hose with Steam Nozzle (FIGURE 4).    Guide key on Extension Hose 
should line up with key slot on base of Steam Nozzle. 
2.  Slide Extension Hose onto Steam Nozzle, being sure to push it on as far as it will go.    Rotate 
Extension Hose clockwise, turning it until you feel it “lock” into place and it will move no further      
(FIGURE 4) 
 
 
 
 
 
 
 

 
 
 
 
 
FIGURE 4 
 

3.

 

Align Jet Nozzle with male end of Extension Hose (FIGURE 5).    Guide key on Jet Nozzle should 
line up with key slot on base of Extension Hose nozzle. 

4.

 

Slide Jet Nozzle onto Extension Hose, being sure to push it on as far as it will go.    Rotate Jet 
Nozzle clockwise, turning it until you feel it “lock” into place and it will move no further      
(FIGURE 5). 

 

 

FIGURE 5 

Filling boiler 

1. 

Place 

Hand Held Steamer 

on a fl

at, level surface. 

2. Make sure power cord is unplugged from electrical outlet. 
3. Cautiously remove Boiler Cap by unscrewing it in a counter-clockwise direction, and lift it off.   

CAUTION: Refer to refilling

 procedure below for additional safety precautions that must be taken 

when refilling the unit after it has been in use.

 

4. Boiler should always be emptied after each use.    If it was not emptied after the previous use, 
empty it before using.  This will make 

it easier to fill with the correct amount of water

 

5. Fill included Measuring Cup with 6 oz. (180 ml.) of water. 
    NOTE: In order to extend the life of your Hand Held Steamer  and keep it functioning  at its 
maximum potential, it is highly recommended that distilled or de-mineralized water be used in 
Boiler. 
6. 

Carefully pour water from Measuring Cup into Boiler through fill hole.

 

    NOTE: Do not exceed the Boiler’s maximum capacity of 6 oz. (180 ml.).  This will ensure a 

better flow of steam with minimal drippi

ng water.   

7. Replace Boiler Cap, screwing it in a clockwise direction to tighten.    Make sure it is screwed on 
securely to prevent hot water or steam from escaping. 
 

Refilling boiler 

    If unit has been in use, always use the following safety precautions before removing  the 

Boiler cap to add water: 

1.

 

Allow unit to cool for 5-10 minutes. 

2.

 

Press  and  hold  Steam  Trigger  to  release  all  remaining  steam.    Steam  can  remain 

pressurized inside Boiler for up to an hour after use. 

WARNING: Failure to follow these precautions may result in burns from escaping steam when   

 

 

GUIDE KEYS 

KEY SLOTS 

Summary of Contents for AFS140

Page 1: ...e it is least likely to be damaged or tripped over during use 3 Before plugging power cord into electrical outlet be sure that all electrical information on rating label agrees with your power supply 4 To reduce likelihood of circuit overload DO NOT operate another high wattage appliance on the same circuit as this unit 5 To protect against risk of electrical shock do not immerse unit in water or ...

Page 2: ...liance before each use by positioning it away from body and turning it on Do not operate unit if Steam Nozzle is blocked 16 Burns can occur from touching hot plastic parts hot water or steam Do not touch Steam Nozzle or attempt to connect any accessories while unit is in use Use caution when you turn Nozzle or attempt to connect any accessories while unit is in use 17 When steaming any surface for...

Page 3: ...of steam for concentrated cleaning The Nylon Utility Brush Brass Utility Brush and Large Brush all connect to the Jet Nozzle Alternatively the Jet Nozzle may be connected to the end of the Extension Hose 8 The Nylon Utility Brush 8 connects to the Jet Nozzle and is designed for scrubbing especially tough stains The Nylon Utility Brush is ideal for use on many surfaces around the home including car...

Page 4: ... its final position Guide keys on Jet Nozzle should line up with key slots on base of Steam Nozzle FIGURE 1 B FIGURE 1 2 Slide Jet Nozzle onto Steam Nozzle guide keys should fit into key slots Push Jet Nozzle on as far as it will go Rotate Jet Nozzle 90º clockwise turning it until it will move no further FIGURE 2 FIGURE 2 Connecting brushes NOTE The Nylon Utility Brush Brass Utility Brush and Large ...

Page 5: ...taken when refilling the unit after it has been in use 4 Boiler should always be emptied after each use If it was not emptied after the previous use empty it before using This will make it easier to fill with the correct amount of water 5 Fill included Measuring Cup with 6 oz 180 ml of water NOTE In order to extend the life of your Hand Held Steamer and keep it functioning at its maximum potential i...

Page 6: ...ny connected accessories approximately 1 2 inch from surface and press Steam Trigger Keep Trigger pressed and concentrate steam on the same spot for at least 5 seconds 6 At its maximum capacity 6 oz 180 ml the Boiler will provide approximately 8 minutes of continuous steam If you wish to continue steaming refer to FILLING BOILER procedure Be sure to note Refilling Boiler section at bottom of page 7...

Page 7: ...sufficient time for unit to heat up before pressing Steam Trigger No water in Boiler Refer to FILLING BOILER procedure to fill unit with water Mineral build up in unit Refer to CARE MAINTENANCE section for details Unit is damaged or otherwise in need of repair Immediately cease usage and unplug Contact manufacturer Steam output is weak or intermittent Water level in Boiler is running low Refer to FI...

Reviews: