4
ENGLISH
·
Air Fitting
: The BN5018A should be equipped with a 1/4” NPT male ‘quick
connector’. To prevent accidental cycling even though disconnected, the tool must
always be connected to the air supply in such a way that all air pressure in it is
released when the coupling is disconnected.
CAUTION
: All air line components (including hoses, pipe, connectors, filters, &
regulators, etc.) must be rated for a minimum working pressure of 150 psi / 1034
kPa / 10.3 bar or 150% of the maximum system pressure, whichever is greater.
Disconnect the tool from the air supply before performing maintenance, clearing a
jammed fastener, leaving the work area, moving the tool to another location, or
handing it to another person.
SETUP: CONNECTING THE TOOL
Turn the compressor on and set the regulator to proper pressure for the size for
the size and type of fasteners being used.
After reading and understanding this entire manual, connect tool to air supply.
CAUTION:
Ö
Keep the tool pointed away from yourself and others at all times.
Ö
Do not load fasteners with air connected, safety or trigger depressed.
Ö
Always wear approved safety glasses and hearing protection when preparing
or operating this tool.
Ö
Never use a tool that leaks air or needs repair.
SETUP: LOADING THE FASTENERS
1
Disconnect the tool from the air supply. Do not load or adjust the tool if it is
connected to the air supply.
2
Depress the LOCK (BN5018A-64) to release the MOVABLE MAGAZINE
(BN5018A-53) and pull the magazine out fully as shown.
3
Place a full stick of the desired type and size of fasteners on the FIXED MAGA-
ZINE (BN5018A-58). Up to 100 fasteners can be loaded in the magazine.
4
Push the MOVABLE MAGAZINE UNIT (BN5018A-53) forward until the LOCK
(BN5018-64) clicks and locks it.
5
The tool is ready to operate.
OPERATING PROCEDURES