VF, DHT, AES Series Manual |
Refrigerated Air Dryer User Manual
23
ventilation for proper cooling, or reduce ambient
temperature.
•
Condenser fan(s) not running - Call Technical Support.
•
Refrigerant control too high - Contact Technical Support
for assistance.
2. Low refrigerant readings generally indicate:
•
Low ambient temperature - Temperatures below 40°F.
Increase ambient temperatures or install head pressure
control valve. Contact Technical Support for more
information.
•
Refrigerant control setting too low - Contact Technical
Support for assistance.
•
Loss of refrigerant - Call Technical Support or qualified
refrigeration service.
7.4 Condensate Removal
The non-cycling refrigerated air dryer uses a refrigeration
circuit to cool the compressed air which causes moisture to
condense. The condensed moisture is separated from the dry
air and purged through an automatic drain.
1. Condensate downstream of dryer:
•
If the unit is equipped with automatic drain override
switch, push manual override button to test drain flow.
•
Ensure automatic electronic timer (if applicable) is
functioning properly.
•
Ensure moisture separator (and coalescer) drain lines are
free from blockage.
•
If the unit is equipped with y-strainer, disassemble and
clean.
•
If oil is downstream from the dryer:
•
Oil coalescer element is saturated.
•
Dryer not turned on during air usage.
WARNING!
Electric Shock Hazard
This machine is connected to high voltage power,
which can cause severe electrical shock and injury.
Follow proper lock out/tag out procedures before
performing service or maintenance work.
WARNING!
Pressure Hazard
• This machine contains contents under high
pressure, which can cause severe injury. To avoid
possible hazard or injury, the operator should be
familiar with the refrigerated air dryer system and
its operation
• When the system is shutdown and power removed,
lock out power supply and depressurize system
before performing maintenance or service work
to avoid injury to personnel or property damage.