NIGHTTIME SETTING 

8.  As a convenience, a nighttime setting switch extinguishes all 

lights on the control panel but leaves all settings in their 
current state. Touch any of the switches to reset the panel to 
the normal lighting.  

AIRCARE

®

 AIR FILTER 

The AIRCARE

®

 filter  #1051 is an excellent means of cleaning the air while using 

your humidifier. The first stage of the air filter is a high-efficiency, electrostatically 
charged filter media which traps dust, pollen, and airborne pollutants. The second 
stage is an activated carbon media which absorbs odors from cooking, pets, or 
tobacco smoke.  

We recommend replacing the AIRCARE

®

 air filter at least once a year and more 

often if necessary.  When the white filter media is coated with a layer of dust and 
dirt, it is time to replace the air filter.  The certified water output of your humidifier 
will be reduced when using the air filter.  The air filters are optional and are not 
required for normal operation of the humidifier. The 1051 is available for purchase 
by calling 1-800-547-3888. 

CARE AND MAINTENANCE 

 

CAUTION: 

Disconnect power before filling, cleaning or servicing unit. Keep grille 

dry at all times.

 

Cleaning your humidifier regularly helps eliminate odors and bacterial and fungal 
growth.  Ordinary household bleach is a good disinfectant and can be used to wipe 
out the humidifier base and bottle/reservoir after cleaning.  We recommend 
cleaning your humidifier at least once every two weeks to maintain optimum 
environmental conditions for your home. 
We also recommend using AIRCARE

®

 or Essick Air

®

 Bacteriostat Treatment each 

time you refill your humidifier to eliminate bacterial growth.  Add bacteriostat 
according to the instructions on the bottle.  Please call 1-800-547-3888 to order 
Bacteriostat Treatment reference part number 1970.   
1.  Turn off unit completely and unplug from outlet. 
2.  Lift out the water bottles and the power pack.  
3.  Carry bottles and base to cleaning basin. Lift wick from the base allowing the 

water to drain. Rinse wick under fresh water only.  Do not use soap, detergent, 
or any other cleaners on the wick.  Leave in sink to drain. 

REMOVING SCALE  

4.  Empty the water from the reservoir and water bottles.  Fill reservoir and each 

water bottle ½ full with water and add 8 oz. (1 cup) of white vinegar to each.  Let 
stand 20 minutes.  Then empty solution. 

5.  Dampen a soft cloth with white vinegar and wipe out reservoir to remove scale. 

Rinse the water bottles and reservoir thoroughly with fresh water to remove 
scale and cleaning solution before disinfecting.  

DISINFECTING UNIT  

6.  Fill each water bottle and reservoir ½ full with water and add 1 teaspoon of 

bleach to each.  Wipe cabinet and bottle surfaces with this solution. Let solution 
stay for 20 minutes, then rinse with water until bleach smell is gone. Dry with 
clean cloth.  The outside of the unit and water bottles may be wiped down with a 
soft cloth dampened with fresh water.  

7.  Refill unit and re-assemble per ASSEMBLY instructions.   

Summary of Contents for 4DTS 300

Page 1: ...ARE GUIDE Adjustable Humidistat Variable Speed Fan Touch Screen Controls TO ORDER PARTS AND ACCESSORIES CALL 1 800 547 3888 1B72896 11 2014 Printed in China READ AND SAVE THESE INSTRUCTIONS COMFORT IS...

Page 2: ...sters radiators stoves or heaters 3 Always unplug the unit before moving cleaning or removing the fan assembly section from the humidifier or whenever it is not in service 4 Keep the humidifier clean...

Page 3: ...of your humidifier Use of other brands of wicks voids the certification of output and may void your warranty HOW YOUR HUMIDIFIER WORKS FEATURES Output per 24 hrs 13 gallons Water tank capacity 5 2 ga...

Page 4: ...ment sample Float and support with two screws Air Filter Manual CASTERS 4 Turn the empty cabinet upside down Insert each caster stem into a caster hole on each corner of the humidifier bottom The cast...

Page 5: ...vel place at least 2 inches away from the wall or curtains Be sure that the humidistat which is located on the power cord is free from obstruction and away from any hot air source FILLING INFORMATION...

Page 6: ...event growth of mildew and mold The unit will automatically turn off after wick is dry If DRY OUT mode is not desired refill the humidifier with water ABOUT HUMIDITY Where you set your desired humidit...

Page 7: ...on the cord that measures the relative humidity in the room When the selected humidity level drops 3 below the relative humidity the humidifier cycles on and off as required to maintain the selected s...

Page 8: ...We recommend cleaning your humidifier at least once every two weeks to maintain optimum environmental conditions for your home We also recommend using AIRCARE or Essick Air Bacteriostat Treatment eac...

Page 9: ...il desired humidity level is achieved This may take up to 48 hours initially Poor evaporation of water CHECK FILTER CF message flashing Mineral buildup on filter wick Change to a fresh new wick NOTE L...

Page 10: ...nating CF and room humidity displayed Wick may be dirty Replace wick if needed Unplug unit for 30 seconds and plug back in to clear display LIST OF REPLACEMENT PARTS Item No Part Number Description Qt...

Page 11: ...11 REPLACEMENT PARTS 1 2 4 5 6 7 10 4 3 8 9...

Page 12: ...ding failure to perform reasonable maintenance normal wear and tear nor where the connected voltage is more than 5 above the nameplate voltage Alterations include the substitution of name brand compon...

Page 13: ...D ENTRETIEN Humidostat r glable Ventilateur variable vitesses Pantalla t ctil digital POUR COMMANDER DES PI CES ET DES ACCESSOIRES APPELEZ LE 1 800 547 3888 INTRODUCCI N LISEZ ET CONSERVEZ CES INSTRUC...

Page 14: ...l humidificateur avant de le d placer Enlever le syst me de ventilation avant de nettoyer ou de faire r parer l humidificateur 4 L humidificateur doit toujours rester propre 5 N introduisez pas de co...

Page 15: ...s humidificateurs des s rie DTS Seuls les filtres m che d vaporation de marque AIRCARE ou Essick Air garantissent le rendement certifi la sortie de votre humidificateur L utilisation de filtres m che...

Page 16: ...bouteilles d eau LES ROULETTES 4 Retournez le bo tier vide de l humidificateur l envers Ins rez une tige de roulette dans chacun des quatre orifices situ s aux quatre coins de la base de l humidificat...

Page 17: ...eur c t d un mur int rieur sur une surface plane au moins 2 pouces 5 cm du mur ou des rideaux Assurez vous que l hygrostat qui est situ sur le cordon d alimentation est libre de tout obstacle et de to...

Page 18: ...T MODE et continuera fonctionner basse vitesse jusqu ce que le filtre soit compl tement sec Le ventilateur s arr tera laissant votre humidificateur sec et moins sujet aux moisissures Si le mode DRY OU...

Page 19: ...les DTS ont un humidostat ajustable qui met en marche et arr te l humidificateur comme n cessaire pour maintenir le r glage s lectionn Lors du d marrage initial l humidit ambiante de la salle sera af...

Page 20: ...eur aide liminer les odeurs et la croissance de bact ries et des moisissures L eau de javel domestique ordinaire est un bon d sinfectant et peut tre utilis e pour essuyer le plateau et les r cipients...

Page 21: ...chiffon doux mouill avec de l eau fra che 7 Remplissez l appareil et remontez le selon les directives d ASSEMBLAGE ENTREPOSAGE PENDANT L T 1 Nettoyez l appareil tel qu indiqu dans le chapitre portant...

Page 22: ...de changer le filtre plus fr quemment Aucun des bidons ne se vide Le piston du bouchon du bidon n est pas comprim par le montant pr vu cet effet au fond du b ti Filtres sales V rifiez l orientation de...

Page 23: ...re a air optionnel 1 6 1B72087 Flotteur 1 7 S98830496C002 Support de flotteur 1 8 S05829815B000 Vis t te cylindrique large Ty AB N 6 x SS 2 9 1B5060140 Tuyau de remplissage 1 10 1B5460100 Roulettes 4...

Page 24: ...t la substitution d l ments de marque y compris mais sans s y limiter les m ches d humidificateur et le traitement des bact ries Nous n assumons pas la responsabilit de tout dommage r sultant de l uti...

Page 25: ...ERIE DTS GU A DE USO Y CUIDADO Humidistato ajustable Ventilador de variable velocidades Pantalla t ctil digital PARA ADQUIRIR PIEZAS Y ACCESORIOS LLAME AL 1 800 547 3888 LEA Y GUARDE ESTAS INSTRUCCION...

Page 26: ...e calor radiadores cocinas o calentadores 3 Siempre desenchufe el humidificador antes de moverlo antes de limpiarlo o cada vez que el humidificador no est funcionando 4 Mantenga el humidificador limpi...

Page 27: ...e su humidificador C MO FUNCIONA SU HUMIDIFICADOR REFERENCIAS 1 Botella de agua 2 Chasis unidad de fuerza conjunto del motor ventilador 3 Filtro mecha evaporador 4 Dep sito de agua 5 Entrada de aire a...

Page 28: ...ben encajar bien justas y se deben insertar hasta que el tope del eje llegue a la superficie del gabinete Poner el gabinete en pie OBSERVACI N Para asegurar las dos botellas se vac an adecuadamente ut...

Page 29: ...comienda orientar la direcci n del aire lejos del termostato y de las rejillas de aire caliente Aseg rese de que el higrostato que se encuentra en el cable de alimentaci n est libre de obstrucci n y l...

Page 30: ...l filtro est completamente seco El ventilador se apagar y dejar su humidificador seco y menos propenso a la aparici n de humedad y moho Si no se desea el MODO DE SECADO AUTOM TICO vuelva a llenar el h...

Page 31: ...istato autom tico que hace entrar en un ciclo de encendido y apagado al humidificador seg n se requiera para mantener el ajuste seleccionado En el encendido inicial se visualizar la humedad ambiente d...

Page 32: ...iones ambientales ideales en su hogar Tambi n recomendamos usar el Tratamiento Antibacteriano Essick Air cada vez que rellene su humidificador para eliminar el crecimiento bacteriano A adir el bacteri...

Page 33: ...los filtros mecha usados y el agua que pueda quedar en el dep sito o botellas y dejar secar bien el gabinete antes de guardarlo No guardarlo con agua dentro del dep sito o botellas 3 No almacenar la u...

Page 34: ...ompruebe la orientaci n de las botellas Reposici nelas de modo que el mbolo v stago de la tapa de la botella sea oprimido por el poste ubicado en el fondo del gabinete Cambie los filtros usando filtro...

Page 35: ...a 2 4 1041 Mecha 1 5 1051 Filtro a reo opcional 1 6 1B72087 Flotador 1 7 S98830496C002 Flotador soporte 1 8 S05829815B000 Tornillo de cabeza troncoc nica tipo AB No 6 x SS 2 9 1B5060140 Manguera de ll...

Page 36: ...e normal ni en situaciones donde el voltaje conectado sea un 5 mayor al indicado por la placa indicadora Las alteraciones que puede sufrir el producto incluyen la sustituci n de componentes de marca i...

Reviews: