(Vers. 10.26.2017)
Page 6 of 24
Series (E) Refractory Walled Air Curtain Burner (Electric Motor & VFD)
OPERATING MANUAL
4)
NEVER use highly combustible materials to light the unit.
Highly combustible materials such as gasoline, refined spirits, etc. ignite at an
explosive rate which may cause serious injury or death. The safest method to
start the fire in the box is to use materials such
as paper and kindling wood. In
the absence of these materials or when starting materials with a high moisture
content use Diesel fuel as an acceptable option.
5)
NEVER climb on the unit to view or light the fire.
Use the ladder built into the unit and never go beyond the top step, or use a
step ladder or similar platform located at a safe distance from the unit. Do not
stand
along the rails or on top of the S
-
Series unit under any circumstance.
6)
Shut the unit down in an emergency.
Stop loading the unit, stop the air flow by pressing the STOP Button on the con
-
trol panel or by disengaging the master switch on the external power supply line.
Dump dirt or sand on to the fire. Water should only be used as a last resort as it
will likely damage the refractory panels.
WIND SPEED VS. SAFE DISTANCE
Approximate Safe Distance for:
Wind Speed
(MPH)
Structures
(Houses, etc.)
Woods/Trees
Stored Brush Piles
10
300'
150'
100'
12
300'
150'
100'
14
300'
200'
150'
16
400'
250'
150'
18
400'
250'
200'
20
500'
250'
200'
DANGER:
The above distances serve as a GUIDELINE ONLY! You
MUST ALWAYS observe the down range area regardless of the wind
speed. You must always observe local fire ordinances and directives
from the local fire department or other authorities.
DANGER:
Falling into the FireBox will cause serious injury or death
.