© Copyright AirBench Ltd 2016
Page 8 of 19
OPERATION
This page contains the same information as the Quick Start guide provided with your AirBench.
Prior to use
Check the system logbook to ensure no routine maintenance is required.
General use
To use AirBench, ensure it is plugged in to a mains socket and the socket is switched on. Turn on the switch on
the front of the bench.
If a speed controller is fitted, turn it to full power before switching on, then adjust it to an appropriate level. Our
recommended settings are shown below:
Fume: 50-75%
Light dusts, 50-100%
Heavy dusts, 75-100%
During commissioning, an optimum setting may have been determined and this should be noted in the system
logbook.
Check the filter pressure gauge on the front of the bench. If the needle on the gauge is showing within the RED
zone, check the filter condition
–
they may require cleaning or replacement.
Your AirBench has a zone above the surface in which capture is most effective, extending between 50cm and
1m in a straight line upwards from the ventilated area. This zone forms a box in which you should aim to do the
majority of your work. Working outside this zone may reduce the effectiveness of the extraction.
Work as normal, aiming to work within the extraction zone described above. On completion of work, switch the
AirBench off using the switch on the front. Record any maintenance you have undertaken, or any that is
required, in the logbook.
To avoid fan overload, do not block more than 95% of the work surface or the air
outlet.