TECHNICAL SPECIFICATIONS

IMPORTANT!

THE SPECIFICATIONS GIVEN IN THIS PUBLICATION DO NOT INCLUDE NORMAL MANUFACTURING

TOLERANCES; THEREFORE, THIS UNIT MAY NOT MATCH THE LISTED SPECIFICATIONS EXACTLY.  ALSO, THIS
PRODUCT IS TESTED AND CALIBRATED UNDER CLOSELY CONTROLLED CONDITIONS AND SOME MINOR
DIFFERENCES IN PERFORMANCE CAN BE EXPECTED IF THOSE CONDITIONS ARE CHANGED.  SPECIFICATIONS
ARE SUBJECT TO CHANGE WITHOUT NOTICE IN THE INTEREST OF CONTINUING PRODUCT DEVELOPMENT.

ELECTRICAL RATING:

115 Vac, 6.5 Amps, 60 Hz, 208-230 Vac, 4 Amps, 60
Hz

AIRFLOW CAPACITY:

With the standard p/n 41190 95% DOP @ 0.3 micron
filter the unit operates on three speeds: Low – 400
CFM, Med – 700 CFM, High – 850 CFM.  These are
calculated with two of the odor/vapor panels.

DIMENSIONS:

39” L x 22 5/8” W x 13¼” H,
90 Lbs. Installed, 115 Lbs. Shipping, add 34 lbs. to the
above weights if the optional carbon modules are
ordered.

MOTOR:

½ Hp, permanent split capacitor, with sealed ball
bearings.

BLOWER WHEEL:

Forward curved, direct drive, 12½” x 4”, single inlet
wheel.

FINE PARTICLE FILTER:

The main particle filter 41190 has a minimum of 102
square feet of media.

PREFILTER:

The standard prefilter is a ½” thick washable
aluminum mesh, PN 41194.  Optional disposable
filters are available.

ODOR / VAPOR FILTER:

The standard MiracleAir™ CM-12 comes with 2
disposable activated carbon filters.  The deluxe
version has two modules, each containing 10
disposable panels for a total carbon weight of 22 lbs.

PLANNING THE INSTALLATION

WARNING!

EXPLOSION HAZARD—Can cause property
damage, severe injury or death.

1.  Do not install where there is any danger of

gas, vapor or dust explosion.

2. 

Do not install if explosion-proof electrical
appliances or fixtures are specified.

APPLICATION & OPERATION

The MiracleAir™ Model CM-12 is designed to be
installed on a ceiling where overhead air cleaning is
required.  Typical applications include offices,
designated smoking areas, computer rooms, data
processing rooms, etc.

Because it provides its own circulation, the CM-12 may
be used in almost any application requiring the
removal of airborne contamination from an enclosed

space.  

The CM-12 must only be used in areas that

are ventilated for human occupancy.

MAKEUP AIR

Recommended quantities of clean outdoor ventilation
air for various applications are described in Table 2 of

the ASHRAE Standard 62-89, “Ventilation for
Acceptable Indoor Air Quality.”  ASHRAE (American
Society of Heating, Refrigerating and Air Conditioning
Engineering, Inc., Telephone #404-636-8400) notes
that these recommended outdoor air quantities may be
reduced by the use of clean, recirculated air if the IAQ
Procedure 6.2 is used.  Appendix E of ASHRAE 62-89
includes recommendations for the use of clean,
recirculated air.  However, in most cases, adequate
control of carbon dioxide generally requires a minimum
clean outdoor air quantity of no less than 15 cubic feet
of air per minute per person.

Summary of Contents for MiracleAir CM-12

Page 1: ...rom Air Quality Engineering Inc is the ultimate solution for indoor air pollution capturing both particulate and gaseous contaminants Odors tobacco smoke pollen dust vapors and many other irritants ar...

Page 2: ...2 TABLE OF CONTENTS PAGE SPECIFICATIONS 3 PLANNING THE INSTALLATION 3 ELECTRICAL INSTALLATION 5 ELECTRICAL SCHEMATIC 6 CHECKOUT 7 MAINTENANCE 7 PARTS LIST DIAGRAM 9 WARRANTY 10...

Page 3: ...ersion has two modules each containing 10 disposable panels for a total carbon weight of 22 lbs PLANNING THE INSTALLATION WARNING EXPLOSION HAZARD Can cause property damage severe injury or death 1 Do...

Page 4: ...x H of Room x Air Changes Hr of CM 12 s CFM of Air x 60 Min CHOOSE LOCATION To ensure even air distribution the CM 12 draws air into the center of the air cleaner and discharges air in four directions...

Page 5: ...n the junction box Note that you may gain better access to the junction box within the cabinet through the discharge end of the air cleaner This can be accomplished by removing the discharge louver wi...

Page 6: ...6 ELECTICAL SCHEMATIC...

Page 7: ...er inspecting the unit for a one or two month time period you will have established the proper cleaning interval for the prefilter When the MiracleAir unit no longer removes odors from the air it is t...

Page 8: ...arge ends of the air cleaner The filters are resting in tracks inside the cabinet There is no locking mechanism to release REPLACING THE ODOR VAPOR FILTERS OF THE CM 12 DELUXE UNITS The standard Mirac...

Page 9: ...9 PARTS LIST AND DIAGRAM...

Page 10: ...EPAIR A showing by the original purchaser that the Product has not been altered repaired or serviced by anyone other than an authorized service technician using genuine AQE parts 4 UNAUTHORIZED PARTS...

Reviews: