STORING, MAINTENANCE, AND SPECIAL ACTIVITIES.
The SK-94 emergency parachute is to be stored under the following
conditions:
The parachute store should be adequately heated and ventilated.
The relative humidity within the parachute store should be between
30%-80%.
The air temperature within the parachute store should be between
10C-30C.
Storage of corrosive materials or contaminants within the
parachute store is expressly forbidden, i.e. acids, alkalis,
solvents, inflammable liquids, oils and petrochemicals.
Storage shelving within the parachute store should not be sited
closer than 1 meter from heating sources.
The maximum period of storage between periodic inspection and
repacking is 1 year (365 days). Unpacking of the parachute prior
to packing and the inspection and repacking is to follow the
instructions in the user manual, without deviation.
Parachutes suspected of becoming soaked with water should be
unpacked in a clean, well ventilated location, kept out of direct
sunlight and hung until completely dry.
Parachutes suspected of becoming soaked with saltwater should
first be thoroughly rinsed with clean freshwater before being
dried as per the previous instruction.
All parts of the parachute assembly are to be allowed to dry
naturally without the application of heat or being wrung out.