Air King ESAPDQ Series Important Instructions And Operating Manual Download Page 3

SECTION 4

Blower Installation for Ducted 
Range Hoods

NOTE:

 When reinstalling the blower, ensure 

that the blower is facing the same way as 
how you have chosen to duct it.

NOTE:

 Makes sure to support the blower in 

position by hand until it is firmly secured to 
the hood.

NOTE: FOR DUCTLESS INSTALLATIONS 
ONLY,

 if you did not already do so in the 

earlier steps, remove the vent block-off plate 
from under the top of the hood 

(Figure 4).

1.  With the opening of the blower facing 

the direction you have chosen to duct 
the hood, place the blower mounting 
brackets (brackets on either side of the 
blower) over the blower mounting studs 
on the interior of the hood 

(Figure 6).

2.  Using the 4 nuts removed earlier, secure 

the blower in place. Start the nuts by 
hand first, then tighten with a 3/8" nut 
driver or ratchet until they are fully 
seated 

(Figure 6).

3.  Plug the blower connector into the 

port on the front wall of the blower 
compartment. It will fit only one way 

(Figure 7).

www.airkinglimited.com

6728029 Rev. G 12-17

3 of 12

CAUTION:

 

DO NOT INSTALL CLOSER THAN 20 INCHES ABOVE 

COOKING SURFACE.

SECTION 6

Wiring

CAUTION:

 ALL ELECTRICAL CONNECTIONS MUST BE 

MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR 

NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING 

ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.

1.  Connect the loose White wire from the range hood to the White wire from the supply, 

and the loose Black wire from the range hood to the Black wire of the supply. Connect 
the ground wire (green or bare) from the supply to the green wire from the hood. Use 
approved methods for all connections 

(Figure 9).

2.  Install the wire compartment cover by reversing the instructions is 

Section 1

Step 3

Make sure all wiring is securely contained within the wire compartment and the nut is 
fully tightened.

SECTION 7

Ducting

CAUTION:

 ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL 

BUILDING CODES.

NOTE:

 The ducting from this fan to the outside of the building has a strong effect on the air 

flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible 
for best performance, and avoid installing the fan with smaller ducts than recommended. 
Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed 
with existing ducts may not achieve their rated air flow.

WARNING:

 TO REDUCE THE RISK OF FIRE, USE ONLY 

METAL DUCTWORK.

1.  Connect the ducting to the hood’s duct collar and damper. Ensure duct joints and exterior 

penetrations are sealed with caulk or other similar material to create an air-tight path to 
minimize building heat loss or gain and to reduce the potential for condensation. Place/
wrap insulation around duct and/or fan in order to minimize possible condensation 
buildup within the duct, as well as building heat loss or gain 

(Figure 10).

SECTION 5

Installing the Range Hood

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE STARTING INSTALLATION.

NOTE:

 If installing into existing construction and you will not have access to the ductwork 

once the hood is in place, make ducting connections at this point. Refer to the Ducting Section 
for instructions.

1.  Install the 4 mounting screws at the previously marked locations. Leave approximately 

1/8" clearance. Slide the hood in place through the keyhole slots and align the front of 
the hood so that it is flush with the front of the cabinets. Tighten all screws securely 

(Figure 8).

Keyhole

1/8

"

Figure 8

Figure 7

Studs

Figure 6

Vertical

Ductless

Horizontal

Studs

Studs

Connector

Fuse

Figure 9

Supply from house

Black

Neutral (White)

Ground (Green or Bare)

Hood

Black

Neutral (White)

Green

Summary of Contents for ESAPDQ Series

Page 1: ...ANY SOLID STATE SPEED CONTROL DEVICE WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boil overs cause smoking and greasy spillovers that m...

Page 2: ...und performance it is recommended that the length of ducting and the number of elbows be kept to a minimum the radius of each elbow be as large as possible for the installation and that hard ducting b...

Page 3: ...Step 3 Make sure all wiring is securely contained within the wire compartment and the nut is fully tightened SECTION 7 Ducting CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES NO...

Page 4: ...1 Remove lamp by gently twisting counterclockwise to release the lamp from the base Installation is the reverse of removal Replace with a compatible GU10 7 watt LED lamp Fuse 1 To replace the fuse tu...

Page 5: ...RS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSE...

Page 6: ...33 7 1 Front Panel 30 5S1145162 1 Front Panel 36 5S1145163 8 2 Lamp Bracket 5S1145160 9 1 Fan Switch 5S1418006 10 1 Light Switch 5S1136069 11 1 Name Plate 5S1421006 12 1 Lamp Holder Assembly 5S1157103...

Page 7: ...D INCENDIE DE GRAISSE SUR LE DESSUS DE LA CUISINI RE a Ne jamais laisser les unit s de surface des degr s lev s sans surveillance Les d bordements par bouillonnement produisent de la fum e et des d b...

Page 8: ...lleure qualit d air et performance acoustique il est recommand que la longueur de la canalisation et le nombre de coudes soient r duits au minimum que le rayon de chaque coude soit aussi grand que pos...

Page 9: ...u ventilateur afin de minimiser la possibilit d accumulation de condensation l int rieur du conduit ainsi que la perte ou le gain de chaleur Figure 10 SECTION 5 Installation de la hotte MISE EN GARDE...

Page 10: ...pe de la base L installation est l inverse de la d pose L installation est l inverse du d montage Remplacez par une lampe compatible de 7W GU10 Fusible 1 Pour remplacer la fusible tournez vers la droi...

Page 11: ...SSUME AUCUNE RESPONSABILIT EXPRESSE OU TACITE POUR I DES DOMMAGES ACCIDENTELS OU INDIRECTS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA R PARATION DE TOUS FUSIBLES DISJONCTEURS OU R CEPTACLES...

Page 12: ...avant 36 po 5S1145163 8 2 Support de lampe 5S1145160 9 1 Interrupteur du moteur 5S1418006 10 1 Interrupteur de la lampe 5S1136069 11 1 Plaque de nom 5S1421006 12 1 Assembl e de Support du Lampe 5S115...

Reviews: