Air King DRLC707 Operating Manual Download Page 5

Troubleshooting Guide

Trouble

Probable Cause

Suggested Remedy

1. Fan does not operate when the switch is on.

1a. A fuse may be blown or a circuit tripped.

1a. Replace fuse or reset circuit breaker.

1b. Connector plug from motor is not plugged in.

1b. Turn off power to unit. Remove Grill and plug motor into receptacle

in housing. Restore power to unit.

1c. Wiring is not connected properly.

1c. Turn off power to unit. Check that all wires are connected.

2. Fan is operating, but air moves slower than normal.

2.

Obstruction in the exhaust ducting.

2.

Check for any obstructions in the ducting. The most common are bird nests

in the roof cap or wall cap where the fan exhausts to the outside.

3. Fan is operating louder than normal.

3a. Motor is loose.

3a. Turn off power to unit. Remove grill and check that all screws are fully

tightened. Restore power to unit.

3b. Fan blade is hitting housing of unit.

3b. Call your dealer for service.

LIMITED WARRANTY

All products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanship
and/or material. In addition, all ventilating/exhaust fans, heaters, combination fan lights and/or heaters, and range hoods are
guaranteed for five years from the date of purchase against defects in workmanship and/or material.

This warranty does not cover any labor or shipping costs or the cost of replacement components as part of routine maintenance
such as: range hood grease filters, charcoal filters or combination charcoal/grease filters; replacement light bulbs in range hoods
or bathroom fan/light/bulb heater combinations. As well, any damage or failure caused by abuse, misuse, abnormal usage, faulty
installation, or improper maintenance will not be covered by this warranty.

In order to make a claim on this warranty, you must be the original consumer of the product. You will be required to present to Air
King the original bill of sale showing: date of purchase, place of purchase and model purchased. Failure to meet these requirements
will void your warranty.

Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or
indirectly by the product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages
and some states do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to
you. This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province.

FOR PARTS OR TECHNICAL ASSISTANCE

Please call: 1-800-465-7300, 

MONDAY THROUGH FRIDAY, BETWEEN THE HOURS OF 8 AM AND 4:00 PM EST.

PLEASE DO NOT RETURN PRODUCT TO PLACE OF PURCHASE.

Reference the type and style of product (located on label inside of the product) when you call.

For more information please visit our website: wwwairkinglimited.com

www.airkinglimited.com

210572092 Rev. A 8-05

5 of 12

Installer: _________________________________________________________

Installation Date:_________________________________________

Place of Purchase: _________________________________________________

Model Number: __________________________________________

Summary of Contents for DRLC707

Page 1: ...including fire related construction 5 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heat...

Page 2: ...o the exhaust fan you should have 1 Grill with Light Lens 1 Damper Assembly attached 2 8 Screws 4 Mounting Rails 1 Instruction Safety Sheet 2 Remove the fan s venturi assembly which is secured in plac...

Page 3: ...ING CODES 1 Connect the ducting to the fan s duct collar Figure 7 Secure in place using tape or screw clamp Always duct the fan to the outside through a wall or roof cap NOTE If damper detaches from u...

Page 4: ...s dishwashing liquid and dry with a soft cloth NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS Completely dry grill before reinstalling Refer to instructions in Section 6 Completing the Installation t...

Page 5: ...eplacement light bulbs in range hoods or bathroom fan light bulb heater combinations As well any damage or failure caused by abuse misuse abnormal usage faulty installation or improper maintenance wil...

Page 6: ...d Nylon Receptacle 2P 5S1201012 9 1 Impeller 5S1299001 10 2 Hex Nut 5S1999006 11 1 Motor 5S2201003 1 10 2 3 5 6 7 8 11 9 14 REPLACEMENT PARTS DIAGRAM Qty Description Replacement Part 12 1 10 Ground Sc...

Page 7: ...isante est requis pour la bonne combustion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combustible pour pr venir un refoulement Suivre les directives du fabricant...

Page 8: ...ur d vacuation vous devriez avoir 1 Grille avec les Lentilles de l clairage 1 Ensemble de clapet attach 2 Vis 8 4 Traverses de Montage 1 Feuillet d instructions s curit 2 Retirer l ensemble venturi du...

Page 9: ...NAUX 1 Raccorder le conduit au collet de conduit du ventilateur Figure 5 Fixer en place l aide de ruban ou de serre joint Toujours vacuer le ventilateur vers l ext rieur au travers de chapeau mural ou...

Page 10: ...er l aide d un chiffon doux NE JAMAIS UTILISER D ABRASIF OU DE POUDRE R CURER S cher compl tement la grille avant de la r installer Pour r installer la grille vous r f rer la Section 6 Compl ter l ins...

Page 11: ...remplacement de composantes faisant partie d entretien de routine tels que Filtres graisse des hottes de cuisine filtres au charbon ou combin filtre graisse charbon ampoules lectriques de remplacement...

Page 12: ...fil en col de cygne 5S1201004 7 1 Vis 8 5S1999004 8 1 R ceptacle 2P Polaris 5S1201012 9 1 H lice 5S1299001 10 2 crou hexagonal 5S1999006 11 1 Motuer 5S2201003 de pi ce Qty Description de remplacement...

Reviews: