GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions should 

always be followed to reduce the risk of fire, electric shock and 

injury to person, including the following:

WARNING:

 TO REDUCE THE RISK 

OF FIRE, ELECTRIC SHOCK AND INJURY TO 

PERSON, OBSERVE THE FOLLOWING: 

a)  Use this unit only in the manner intended by the manufacturer.If you have 

questions, contact the manufacturer.

b)  Before servicing or cleaning the unit, switch power off at service 

panel and lock the service disconnecting means to prevent power 

from being switched on accidentally. When the service disconnecting 

means cannot be locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.

WARNING:

 TO REDUCE THE RISK 

OF FIRE, ELECTRIC SHOCK AND INJURY TO 

PERSON, OBSERVE THE FOLLOWING: 

a)  Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-related construction.

b)  Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to prevent 

back drafting. Follow the heating equipment manufacturer’s guideline 

and safety standards such as those published by the National Fire 

Protection Association (NFPA) and the American Society for Heating, 

Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local 

code authorities.

c)  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

CAUTION:

 

FOR GENERAL VENTILATING USE ONLY. 

DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE 

MATERIALS AND VAPORS.

d)  Ducted fans must always be vented to the outdoors.
e)  If this unit is to be installed over a tub or shower, it must be marked 

as appropriate for the application and be connected to a GFCI (Ground 

Fault Circuit Interrupter) – protected branch circuit. 

f)  This unit must be grounded.
g)  To avoid motor bearing damage and noisy and/or unbalanced impellers, 

keep drywall spray, construction dust, etc. off power unit.

h)  Read all instructions before installing or using exhaust fan.

WARNING:

 TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK, DO NOT USE THIS FAN WITH 

ANY SOLID-STATE SPEED CONTROL DEVICE.

WARNING:

 DO NOT USE IN KITCHENS.

WARNING:

 

THE DUCTING FROM THIS FAN TO THE 

OUTSIDE OF THE BUILDING HAS A STRONG EFFECT ON THE 

AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE THE SHORTEST, 

STRAIGHTEST DUCT ROUTING POSSIBLE FOR BEST PERFORMANCE, 

AND AVOID INSTALLING THE FAN WITH SMALLER DUCTS THAN 

RECOMMENDED. INSULATION AROUND THE DUCTS CAN REDUCE 

ENERGY LOSS AND INHIBIT MOLD GROWTH. FANS INSTALLED WITH 

EXISTING DUCTS MAY NOT ACHIEVE THEIR RATED AIRFLOW.

Summary of Contents for D4S

Page 1: ...ent air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code auth...

Page 2: ...the previously cut hole so that it is flush with the finished ceiling Secure the ends of the rails to the joists Figure 1 www airkinglimited com 6727900 Rev D 9 16 2 of 12 SECTION 4 Ducting NOTE 6 OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES NOTE The ducting from this fan to the outside of the building has a strong ...

Page 3: ... to the green wire from the fan housing Figure 9 Use approved methods for all connections NOTE The yellow wire may contain a wire crimp nut which will have to be cut off and the wire stripped 4 Carefully tuck wire back inside wire compartment and replace wire compartment cover securing with the screw that was removed earlier SECTION 6 Completing the Installation 1 Use a sealant appropriate for con...

Page 4: ...nimum on time to 30 minutes see numbers in Step 2b The sensor will then flash the number of times for the new setting 3 times before exiting back to the programming mode 3 Once all setting have been made and the sensor will return to detection mode and the LED will flash when occupancy of the room is detected SECTION 8 Setting the Humidistat This fan may be equipped with a humidity sensor that aut...

Page 5: ... does not apply if the product was damaged or failed because of accident improper handling or operation shipping damage abuse misuse unauthorized repairs made or attempted This warranty does not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL WARRANTIE...

Page 6: ...acement Part 7 1 Grill 5S1202048 8 1 Wire Compartment Assembly 5S1250103 Specific to Model D4SG Qty Description Replacement Part 9 1 Wire Compartment Assembly 5S1250114 15 1 Grill Assembly 5S1239115 Specific to Model D4SH Qty Description Replacement Part 7 1 Grill 5S1202048 10 1 Wire Compartment Assembly 5S1250115 13 1 Knob 5S1299802 14 1 Humidity Sensor Compartment 5S1239826 Specific to Models D4...

Page 7: ...uit cheminée provenant d équipement de brûlage au combustible pour prévenir un refoulement Suivre les directives du fabricant de l équipement de chauffage et les normes de sécurité telles que celles publiées par la National Fire Protection Association NFPA et de la American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et de celles des autorités locales du code c Lors de ...

Page 8: ...es rails aux solives Figure 1 www airkinglimited com 6727900 Rev D 9 16 8 of 12 SECTION 4 Conduits NOTE UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE MEILLEURE PERFORMANCE ATTENTION TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX REMARQUE La canalisation de ce ventilateur à l extérieur du bâtiment a un effet important sur le flux d air le bruit e...

Page 9: ...ectez le fil de la position automatique sur l interrupteur mural au fil noir du ventilateur connectez le fil de la position manuelle sur l interrupteur au fil jaune du ventilateur Connectez le fil de terre de la maison au fil vert du boîtier du ventilateur Figure 9 Utiliser des méthodes approuvées pour toutes les connexions REMARQUE Le fil jaune peut contenir un écrou de fil à sertir qui devra êtr...

Page 10: ...de mouvement sur le gril du ventilateur et appuyez sur le bouton 10 fois Le LED sur le capteur clignote alors le nombre de fois pour indiquer le réglage actuel Ceci sera répété 3 fois 1 fois 0 minutes 4 fois 45 minutes 2 fois 15 minutes 5 fois 60 minutes 3 fois 30 minutes 2c Pour ajuster le réglage tandis que le capteur est continue de clignoter de l étape 2b appuyez sur le bouton le nombre de foi...

Page 11: ...te garantie ne couvre pas les coûts d expédition pour le retour des produits à Air King pour la réparation ou le remplacement Air King payera les frais d expédition de retour de Air King après les réparations ou le remplacement de garantie TOUTES LES GARANTIES EXPRESSES OU TACITES COMPRENANT SANS LIMITATION TOUTE GARANTIE TACITE DE VALEUR MARCHANDE DURENT UN AN DE LA DATE DE L ACHAT ORIGINAL OU JU...

Page 12: ... 5S1202048 8 1 Assemblée du compartiment du fil 5S1250103 Particularités de modèle D4SG Qté Description de pièce de remplacement 9 1 Assemblée du compartiment du fil 5S1250114 15 1 Assemblée de Grille 5S1239115 Particularités de modèle D4SH Qté Description de pièce de remplacement 7 1 Grille 5S1202048 10 1 Assemblée du compartiment du fil 5S1250115 13 1 Bouton 5S1299802 14 1 Compartiment du capteu...

Reviews: