Air King BFQL120 Important Instructions & Operating Manual Download Page 5

www.airkinglimited.com

6727919 Rev. G 11-18

5 of 12

Installer: 

 

Installation Date: 

Place of Purchase: 

 

Model Number: 

LIMITED WARRANTY

WHAT THIS WARRANTY COVERS:

 This product is warranted against defects in workmanship and/or materials. 

HOW LONG THIS WARRANTY LASTS:

 This warranty extends only to the original purchaser of the product and lasts for five (5) years from the date of original purchase 

or until the original purchaser of the product sells or transfers the product, whichever first occurs. 

WHAT AIR KING WILL DO:

 During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole 

product with the same or comparable model. 

WHAT THIS WARRANTY DOES NOT COVER:

 This warranty does not apply if the product was damaged or failed because of accident, improper handling, installation, or 

operation, shipping damage, abuse, misuse, unauthorized repairs made or attempted. This warranty does not cover shipping costs for the return of products to Air King for 

repair or replacement. Air King will pay return shipping charges from Air King following warranty repairs or replacement 

ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY), LAST FIVE YEARS 

FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT, WHICHEVER FIRST 

OCCURS AND IN NO EVENT SHALL AIR KING’S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES 

FROM ANY CAUSE WHATSOEVER, OR (II) REPLACMENT OR REPAIR OF ANY HOUSE FUSES, CIRCUIT BREAKERS OR RECEPTACLES. NOTWITHSTANDING ANYTHING TO 

THE CONTRARY, IN NO EVENT SHALL AIR KING’S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT 

AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.

Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so these 

exclusions or limitations may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state to state and province to 

province. Proof of purchase is required before a warranty claim will be accepted. 

CUSTOMER SERVICE:

Toll-Free (800) 465-7300

Our Customer Service team is available to assist you with product questions, service center locations, and replacement parts. They can be reached Monday through 

Friday, 8am-4pm Eastern. Please have your model number available, as well as the type and style (located on the label inside of your product). 

Please do not return product to place of purchase.

www.airkinglimited.com

PARTS FOR DISCONTINUED, OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE. DUE TO SAFETY REASONS, MANY ELECTRONIC COMPONENTS 

AND MOST HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT.

Summary of Contents for BFQL120

Page 1: ...including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditio...

Page 2: ...e bottom of the fan will be flush with the finished ceiling Nail or screw the bracket in place securely Figure 3 2 Snap the fan body into the bracket Figure 4 The fan can be snapped into position with the duct collar facing to the left or the right depending which is most convenient www airkinglimited com 6727919 Rev G 11 18 2 of 12 SECTION 3 Existing Construction 1 Position housing against the jo...

Page 3: ...wire from the fan s light receptacle and the white wire from the fan s exhaust receptacle Connect the black wire from the wall switch to both the black wire from the fan s light receptacle and the black wire from the fan s exhaust receptacle Connect the ground wire from the house to the green wire from the fan s receptacle Figure 9 Use approved methods for all connections SECTION 6 Completing the ...

Page 4: ...quid and dry with a soft cloth NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS Completely dry grill before reinstalling Refer to instructions in Section 6 Finishing the Installation to reinstall grill Cleaning the Fan Assembly Unplug the motor cord from receptacle Wipe all parts with a dry cloth or gently vacuum the fan NEVER IMMERSE ELECTRICAL PARTS IN WATER Plug the motor cord back in and restor...

Page 5: ...NSFERS THE PRODUCT WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED TH...

Page 6: ...lip 5S2205025 6 1 Wire Cover 5S2205040 7 1 Blower Wheel 5S2299004 8 1 Motor BFQL50 BFQLA50 5S2205035 1 Motor BFQL60 5S2205036 1 Motor BFQL70 5S2205037 1 Motor BFQL80 5S2205034 1 Motor BFQL120 BFQLA120 5S2299002 9 1 Reflector Bracket 5S2205029 10 1 Motor Bracket 5S2299003 11 1 Grill Assembly 5S9205030 12 1 Light Lens 5S2205031 13 1 6 Watt LED Lamp 5S1299725 1 11 5 Watt LED Lamp BFQLA50 BFQLA120 5S1...

Page 7: ...onne combustion et l évacuation de gaz par le conduit cheminée provenant d équipement de brûlage au combustible pour prévenir un refoulement Suivre les directives du fabricant de l équipement de chauffage et les normes de sécurité telles que celles publiées par la National Fire Protection Association NFPA et de la American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et ...

Page 8: ...essous du ventilateur soit à effleurement avec le plafond fini Clouer ou visser solidement le support en place Figure 3 www airkinglimited com 6727919 Rev G 11 18 8 of 12 2 Fixer par pression le bâti du ventilateur dans le support Figure 4 Le ventilateur peut être fixé par pression en position avec le collet de conduit faisant face à gauche ou à droite en fonction de quelle direction est la plus p...

Page 9: ...l interrupteur mural Fixer les câbles électriques au châssis avec un connecteur électrique approuvé Vous assurer de laisser suffisamment de câble dans la boîte pour faire le raccordement au réceptacle du ventilateur 2a Par là où vous avez accès à l intérieur de la boîte de jonction du ventilateur raccorder un fil blanc provenant de la maison aux deux fils blancs du réceptacle de la lumière et le f...

Page 10: ...lace dans la douille Figure 12 www airkinglimited com 6727919 Rev G 11 18 10 of 12 5 Réinstallez la lentille dans le grille 6 Restaurer l alimentation et tester votre installation SECTION 7 Utilisation et entretien ATTENTION VOUS ASSURER QUE L ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION ATTENTION PERMETTRE À L AMPOULE DE SE REFROIDIR AVANT DE LA REPLACER Remplac...

Page 11: ...els ou indirects et par conséquent les présentes restrictions ne peuvent pas s appliquer La présente garantie vous donne des droits légaux spécifiques et peut être certains autres droits qui peuvent varier selon la province La preuve d achat est exigée avant qu une réclamation de garantie ne soit acceptée SERVICE À LA CLIENTÈLE Sans frais 800 465 7300 Notre équipe de service à la clientèle est dis...

Page 12: ... 5S2205004 4 1 Réceptacle de la Lumière 5S1201012 5 2 Clip 5S2205025 6 1 Couvercle des câbles 5S2205040 7 1 Roue de la Soufflante 5S2299004 8 1 Moteur BFQL50 BFQLA50 5S2205035 1 Moteur BFQL60 5S2205036 1 Moteur BFQL70 5S2205037 1 Moteur BFQL80 5S2205034 1 Moteur BFQL120 BFQLA120 5S2299002 9 1 Support du Réflecteur 5S2205029 10 1 Support du Moteur 5S2299003 11 1 Assemblée de grille 5S9205030 12 1 L...

Reviews: