Air King BFQL120 Important Instructions & Operating Manual Download Page 4

CAUTION:

 FAILURE TO SECURE THE REFLECTOR BOLT 

MAY RESULT IN A RATTLING OR HUMMING NOISE.

4.  After the reflector bolt is secure, raise the grill/reflector up into position 

and plug the reflector into the appropriate receptacle. Secure the 
assembly to the reflector bolt using the acorn nut and lock washer. 
Install the included LED lamp into the lamp holder by lining up the pins 
on the lamp base to the socket of the lamp holder and turning the lamp 
body clockwise until the lamp snaps into place and is firmly seated in 
the lamp holder 

(Figure 12).

5.  Reinstall the lens into the grill.

 

6.  Restore power and test your installation.

www.airkinglimited.com

6727919 Rev. G 11-18

4 of 12

SECTION 7

Use and Care

CAUTION:

 MAKE SURE POWER IS SWITCHED 

OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT.

CAUTION:

 ALLOW BULB TO COOL BEFORE REPLACING.

Changing the Lamp

Remove the light lens by squeezing at the tabs and pulling down 

(Figure 

13).

 Remove lamp by gently twisting the lamp base counterclockwise while 

applying outward pressure. Installation is the reverse of removal. Replace 

with Air King model AK6LED40 or a compatible GU24 6 watt LED lamp 

(models BFQLA50, BFQLA120 - compatible GU24 11.5 watt LED lamp).

Cleaning the Grill

Remove grill and use a mild detergent, such as dishwashing liquid, and 

dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING 

POWDERS. Completely dry grill before reinstalling. Refer to instructions in 

Section 6

 

Finishing the Installation

, to reinstall grill.

Cleaning the Fan Assembly

Unplug the motor cord from receptacle. Wipe all parts with a dry cloth or 

gently vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER. 

Plug the motor cord back in and restore power.

Troubleshooting Guide

    Trouble 

 

Probable Cause 

 

Suggested Remedy

  1.  Fan does not operate when the switch is on. 

1a.  A fuse may be blown or a circuit tripped. 

1a.  Replace fuse or reset circuit breaker.

     

1b.  Connector plug from motor is not plugged in.  1b.  Turn off power to unit. Remove Grill and plug motor into receptacle

     

 

 

 

in housing. Restore power to unit.

     

1c.  Wiring is not connected properly. 

1c.  Turn off power to unit. Check that all wires are connected.

     

1d 

Motor has stopped operating. 

1d.  Replace motor.

  2.  Fan is operating, but air moves slower than normal. 

2. 

Obstruction in the exhaust ducting. 

2. 

Check for any obstructions in the ducting. The most common are bird

     

 

 

 

nests in the roof cap or wall cap where the fan exhausts to the outside.

  3.  Fan is operating louder than normal 

3a.  Motor is loose. 

3a.  Turn off power to unit. Remove grill and check that all screws are fully

     

 

 

 

tightened. Restore power to unit.

     

3b.  Fan blade is hitting housing of unit. 

3b.  Call your dealer for service.

Tabs

Figure 13

Figure 12

Motor Clip

Mounting Bolt

Reflector

Grill

Lens

Tabs

Flange Nut

Figure 11

Nut

Summary of Contents for BFQL120

Page 1: ...including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditio...

Page 2: ...e bottom of the fan will be flush with the finished ceiling Nail or screw the bracket in place securely Figure 3 2 Snap the fan body into the bracket Figure 4 The fan can be snapped into position with the duct collar facing to the left or the right depending which is most convenient www airkinglimited com 6727919 Rev G 11 18 2 of 12 SECTION 3 Existing Construction 1 Position housing against the jo...

Page 3: ...wire from the fan s light receptacle and the white wire from the fan s exhaust receptacle Connect the black wire from the wall switch to both the black wire from the fan s light receptacle and the black wire from the fan s exhaust receptacle Connect the ground wire from the house to the green wire from the fan s receptacle Figure 9 Use approved methods for all connections SECTION 6 Completing the ...

Page 4: ...quid and dry with a soft cloth NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS Completely dry grill before reinstalling Refer to instructions in Section 6 Finishing the Installation to reinstall grill Cleaning the Fan Assembly Unplug the motor cord from receptacle Wipe all parts with a dry cloth or gently vacuum the fan NEVER IMMERSE ELECTRICAL PARTS IN WATER Plug the motor cord back in and restor...

Page 5: ...NSFERS THE PRODUCT WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED TH...

Page 6: ...lip 5S2205025 6 1 Wire Cover 5S2205040 7 1 Blower Wheel 5S2299004 8 1 Motor BFQL50 BFQLA50 5S2205035 1 Motor BFQL60 5S2205036 1 Motor BFQL70 5S2205037 1 Motor BFQL80 5S2205034 1 Motor BFQL120 BFQLA120 5S2299002 9 1 Reflector Bracket 5S2205029 10 1 Motor Bracket 5S2299003 11 1 Grill Assembly 5S9205030 12 1 Light Lens 5S2205031 13 1 6 Watt LED Lamp 5S1299725 1 11 5 Watt LED Lamp BFQLA50 BFQLA120 5S1...

Page 7: ...onne combustion et l évacuation de gaz par le conduit cheminée provenant d équipement de brûlage au combustible pour prévenir un refoulement Suivre les directives du fabricant de l équipement de chauffage et les normes de sécurité telles que celles publiées par la National Fire Protection Association NFPA et de la American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et ...

Page 8: ...essous du ventilateur soit à effleurement avec le plafond fini Clouer ou visser solidement le support en place Figure 3 www airkinglimited com 6727919 Rev G 11 18 8 of 12 2 Fixer par pression le bâti du ventilateur dans le support Figure 4 Le ventilateur peut être fixé par pression en position avec le collet de conduit faisant face à gauche ou à droite en fonction de quelle direction est la plus p...

Page 9: ...l interrupteur mural Fixer les câbles électriques au châssis avec un connecteur électrique approuvé Vous assurer de laisser suffisamment de câble dans la boîte pour faire le raccordement au réceptacle du ventilateur 2a Par là où vous avez accès à l intérieur de la boîte de jonction du ventilateur raccorder un fil blanc provenant de la maison aux deux fils blancs du réceptacle de la lumière et le f...

Page 10: ...lace dans la douille Figure 12 www airkinglimited com 6727919 Rev G 11 18 10 of 12 5 Réinstallez la lentille dans le grille 6 Restaurer l alimentation et tester votre installation SECTION 7 Utilisation et entretien ATTENTION VOUS ASSURER QUE L ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION ATTENTION PERMETTRE À L AMPOULE DE SE REFROIDIR AVANT DE LA REPLACER Remplac...

Page 11: ...els ou indirects et par conséquent les présentes restrictions ne peuvent pas s appliquer La présente garantie vous donne des droits légaux spécifiques et peut être certains autres droits qui peuvent varier selon la province La preuve d achat est exigée avant qu une réclamation de garantie ne soit acceptée SERVICE À LA CLIENTÈLE Sans frais 800 465 7300 Notre équipe de service à la clientèle est dis...

Page 12: ... 5S2205004 4 1 Réceptacle de la Lumière 5S1201012 5 2 Clip 5S2205025 6 1 Couvercle des câbles 5S2205040 7 1 Roue de la Soufflante 5S2299004 8 1 Moteur BFQL50 BFQLA50 5S2205035 1 Moteur BFQL60 5S2205036 1 Moteur BFQL70 5S2205037 1 Moteur BFQL80 5S2205034 1 Moteur BFQL120 BFQLA120 5S2299002 9 1 Support du Réflecteur 5S2205029 10 1 Support du Moteur 5S2299003 11 1 Assemblée de grille 5S9205030 12 1 L...

Reviews: