  #    Qty.  Description 

Replacement Part # 

  1    1 

Wire Box 

5S1138002 

  2    1 

Main Wire 

5S1138003 

  3    1 

Cabinet - 30" models 

5S1138630 

      1 

Cabinet - 36

"

 models 

5S1138640 

  4    1 

Grease Tray - 30

"

 

5S1138230 

      1 

Grease Tray - 36

"

 

5S1138240 

  5    3 

Grease Filter 30

"

 models 

5S1138010 

      3 

Grease Filter 36

"

 models 

5S1139011 

  6    1 

Fan Switch with Harness 

5S1138012 

  7    1 

Light Switch with Harness 

5S1138013 

  8    1 

Name Plate 

5S1138014 

  9    2 

Knob 

5S1136073 

  10    1 

Internal Panel 30

"

 models 

5S1138730 

      1 

Internal Panel 36

"

 models 

5S1138740 

  11    1 

Sub Wire Harness without Lamp 

5S1138018 

  12    1 

Wire Harness 

5S1138008 

All 18" High Models

  #    Qty.  Description 

Replacement Part # 

  13    1 

Front Panel AP1830 

5S1138830 

      1 

Front Panel AP1836 

5S1138840 

  14    3 

Lamp Holder 

5S1138022 

Specific to Halogen Lamp models

  #    Qty.  Description 

Replacement Part # 

  13    1 

Front Panel AP1830W 

5S1138830 

      1 

Front Panel AP1836W 

5S1138840 

  14    3 

Lamp Holder 

5S1136075 

  15    2 

Heat Lamp Switch Harness 

5S1138012 

  16    2 

Heat Lamp Holder 

5S1136076 

Specific to Halogen Lamp with Heat Lamp models

13

14

15

16

1

2

3

4

5

6

7

8

9

10

11

12

14

13

Specific to Halogen Lamp models

Specific to Halogen Lamp with Heat Lamp models

REPLACEMENT PARTS DIAGRAM - 18" MODELS

Summary of Contents for AP1030

Page 1: ...age electrical wiring and other hidden utilities CAUTION TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR BE SURE TO DUCT AIR OUTSIDE DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS...

Page 2: ...adjusted accordingly The hood must be mounted a minimum of 24 and a maximum of 36 from the cooking surface Figure 2 www airkinglimited com A111597016 Rev A 12 09 2 of 16 NOTE When determining the heig...

Page 3: ...ill the appropriate holes for mounting The back splash must be installed before the hood canopy because the hood canopy will cover the backsplash mounting screws Refer to the instructions included wit...

Page 4: ...ch dry wall or secure the hood If this is your situation Air King recommends that you hire a professional and comply with all applicable codes 8 Install the proper sized outlet adapter available separ...

Page 5: ...he same speed On installation where a Two 2 speed blower is utilized the Medium and High speeds operate at the same speed Heat Lamp Controls For models equipped with heat lamps two On Off rocker switc...

Page 6: ...roducts to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WI...

Page 7: ...Internal Panel 36 models 5S1138740 11 1 Sub Wire Harness without Lamp 5S1138018 12 1 Wire Harness 5S1138008 All 18 High Models Qty Description Replacement Part 13 1 Front Panel AP1830 5S1138830 1 Fron...

Page 8: ...1138006 11 2 Knob 5S1136073 12 1 Internal Panel 30 models 5S1138430 1 Internal Panel 36 models 5S1138440 13 1 Sub Wire Harness without Lamp 5S1138007 14 1 Wire Harness 5S1138008 All 10 High Models Qty...

Page 9: ...LES RISQUES D INCENDIE ET POUR VACUER L AIR AD QUATEMENT ASSUREZ VOUS D VACUER L AIR VERS L EXT RIEUR NE PAS VACUER L AIR DANS DES ESPACES DANS LES MURS LES PLAFONDS OU LES GRENIERS LES GALERIES TECH...

Page 10: ...un minimum de 24 po et un maximum de 36 po cm de la surface de cuisson Figure 2 www airkinglimited com A111597016 Rev A 12 09 10 of 16 REMARQUE Lorsque vous d terminez la hauteur entre le couvert et l...

Page 11: ...barit pour la localisation et percez les trous appropri s pour le montage Le dosseret doit tre install avant le couvert de la hotte parce que le couvert de la hotte couvrira les vis de montage du doss...

Page 12: ...fixer la cloison s che et pour fixer la hotte Si vous rencontrez cette situation Air King recommande que vous embauchiez un professionnel et que vous vous conformiez avec tous les codes du b timent a...

Page 13: ...o un ventilateur deux 2 vitesses est utilis les vitesses MOYENNE et HAUTE op rent la m me vitesse Contr les des lampes chauffantes Pour les mod les quip s de lampes chauffantes deux commutateurs En H...

Page 14: ...s d exp dition pour le retour des produits Air King pour la r paration ou le remplacement Air King payera les frais d exp dition de retour de Air King apr s les r parations ou le remplacement de garan...

Page 15: ...s de 36 po panneau interne 5S1138740 11 1 Harnais de sous c blage sans lampe 5S1138018 12 1 Harnais de fils 5S1138008 Tous les mod les de 18 po de pi ce Qt Description de remplacement 13 1 Panneau fro...

Page 16: ...l tique 5S1138006 11 2 Boutons 5S1136073 12 1 Mod les de 30 po panneau interne 5S1138430 1 Mod les de 36 po panneau interne 5S1138440 13 1 Harnais de sous c blage sans lampe 5S1138007 14 1 Harnais de...