Air King AKEV Series Operating Manual Download Page 8

www.airkinglimited.com

6728104 Rev. B 5-20

8 of 8

Replacement Parts

Model AKEV95

#

Qty.

Description

Replacement Part #

1

1

Door Latch

5S7758001

2

2

Hinge Knuckle and Pins

5S7760001

3

1

Circuit Board

5S7758002

4

2

Motor

5S7758003

5

1

Fuse Holder

5S7760002

6

1

Fuse (2.5 Amp)

5S7760003

7

1

10 Position Screw Terminal

5S7760004

8

1

4 Position Screw Terminal

5S7760005

9

1

Striker Plate

5S7758004

10

1

Core

5S7758005

11

1

Door Switch

5S7760006

12

1

Door Assembly

5S7758006

13

2

Core Filter*

5S7760007

14

2

Motor Capacitor

5S7758007

19

1

RVC8 Wall Control

5S7760008

4

6

7

5

1

3

8

9

2

10

11

Model AKEV160

#

Qty.

Description

Replacement Part #

1

2

Motor

5S7759001

2

2

Capacitor

5S7759002

3

1

Circuit Board

5S7759003

4

1

10 Position Screw Terminal

5S7760004

5

1

4 Position Screw Terminal

5S7760005

6

2

Hinge Knuckle and Pins

5S7760001

7

2

Draw Latch

5S7759004

8

2

Keeper

5S7759005

9

1

Door Switch

5S7760006

10

1

Core

5S7759006

11

1

Door Assembly

5S7759007

12

1

Fuse Holder

5S7760002

13

1

Fuse (2.5 amp)

5S7760003

14

1

Transformer

5S7759001

15

2

Core Filter*

5S7760007

19

1

RVC8 Wall Control

5S7760008

1 2

3

5

10

11

8

6

7

12

13

14

4

9

Model AKHV160

#

Qty.

Description

Replacement Part #

1

2

Motor

5S7759001

2

2

Capacitor

5S7759002

3

1

Circuit Board

5S7759003

4

1

10 Position Screw Terminal

5S7760004

5

1

4 Position Screw Terminal

5S7760005

6

2

Hinge Knuckle and Pins

5S7760001

7

2

Draw Latch

5S7759004

8

2

Keeper

5S7759005

9

1

Door Switch

5S7760006

10

1

Core

5S7760009

11

1

Door Assembly

5S7759007

12

1

Fuse Holder

5S7760002

13

1

Fuse (2.5 amp)

5S7760003

14

1

Transformer

5S7759001

15

2

Core Filter*

5S7760007

16

1

Drain Fitting

5S7759010

17

1

Motor Damper

5S7759011

18

2

Damper Torsion Springs

5S7759012

19

1

RVC8 Wall Control

5S7760008

16

17

18

6

12

2

13

14

15

*  Core filters come in 2 per package and need to be cut to size.
  HRV filters are located in lower quadrants of unit.

19

Summary of Contents for AKEV Series

Page 1: ...perature falls below 32 F i This unit must be grounded The power cord is equipped with a three prong grounded plug that must be inserted into a matching receptacle Under no circumstances should the gr...

Page 2: ...used to transfer stale air from the wet rooms to the ERV HRV 2 Extended System Continuous Ventilation The furnace fan may not need to run continuously with this system Check local code requirements Fo...

Page 3: ...ITH METHODS OF INSTALLING ELECTRICAL WIRING SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN For simplified return return duct systems it is mandatory that the unit be interlocked with the furnace blowe...

Page 4: ...ed until the humidity level drops below setpoint Available humidity setting range 20 80 In cases where humidity control is not desired or practical use the arrow keys to toggle the humidity setpoint t...

Page 5: ...peed in the ventilator The unit will run in high speed until the ambient air returns to the setpoint RH Your ventilator is not a dehumidifier however ventilating can have a dehumidifying effect by sim...

Page 6: ...re present Install back draft dampers as needed Check defrost system Note minimal frost build up is expected on cores before unit initiates defrost cycle function The supply air feels cool ERV HRV air...

Page 7: ...NTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACEMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN N...

Page 8: ...Latch 5S7759004 8 2 Keeper 5S7759005 9 1 Door Switch 5S7760006 10 1 Core 5S7759006 11 1 Door Assembly 5S7759007 12 1 Fuse Holder 5S7760002 13 1 Fuse 2 5 amp 5S7760003 14 1 Transformer 5S7759001 15 2 C...

Reviews: