background image

SECTION 4

Installing Backsplash

1.  If an optional BS Series backsplash will be utilized, this must be installed before the hood 

canopy because the hood canopy will cover the backsplash mounting screws. Refer to 
the instructions included with the backsplash for installation.

SECTION 5

Wall Mounted Canopy Installation

CAUTION:

 ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL 

BUILDING CODES.

WARNING:

 TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

1.  Determine the type of ducting you will require 

(Figure 6).

NOTE:

 When the duct termination is similar to that shown in 

Figure 6

 (passing through the wall 

to which the hood is mounted) the installation requires special consideration. Depending upon 
where the wall studs are located, it may be necessary to cut one or more of the wall studs and 
install a header and footer to transfer the load to the adjacent studs. Additional studs may need 
to be framed into the opening to attach dry wall or secure the hood. If this is your situation Air 
King recommends that you hire a professional and comply with all applicable codes.

2.  Install the proper sized outlet adapter (available separately) to the hood by matching up 

the four holes on the flange of the adapter to the four corresponding holes on the hood and 
secure in place with the provided screws. Ensure an airtight seal around the adapter by 
securing all connections with ducting tape 

(Figure 7).

NOTE:

 If the recommended, optional BS Series backsplash is being installed it must be 

installed before the hood canopy because the hood canopy will cover the backsplash 
mounting screws. Refer to the instructions included with the backsplash for complete 
installation instructions.

3.  Rest the cavity in the back side of the hood on the wood strip and secure hood to wood 

strip with the included 3/4" screws through the holes in the back of the hood that line up 
with the wood strip (use 6 screws for 30" and 36" widths and 8 screws for larger widths) 
Secure the bottom of the hood by installing the screws provided into the wall anchors 

(Figure 8).

www.airkinglimited.com

A111597016 Rev. F 4-12

3 of 16

4.  Connect the ducting to the outlet adapter and damper. Secure in place using tape to seal 

all joints 

(Figure 9).

SECTION 6

Under Cabinet Canopy Installation

1.  If the canopy will be installed under cabinets that have a recessed bottom, it will be 

necessary to install wood mounting strips (not included) so the canopy will mount 

properly 

(Figure 10).

2.  The thickness of the strips should be the same as the recess of the cabinet and they 

should be approximately 2” wide.

3.  Install the strips using appropriate length wood screws (not included). Make sure the 

strips line up to the holes in the top of the canopy.

4.  Mark the location where the outlet adapter (available separately) will be located on the 

cabinets and cut a hole approximately 1” larger on all sides than the outlet adapter 

(Figure 11).

Figure 6

Wall Cap

Outlet 

Adapter

Roof Cap

Horizontal

Vertical

Figure 7

Hood

Screw

Flange

Outlet Adapter

Figure 8

Hood

Screw

Wood 

Mounting 

Strip

Wall Anchor

Hood

Outlet Adapter

Damper

Ducting

Figure 9

Figure 10

Wood Strip

Figure 11

Hole

Summary of Contents for Advantage Professional Series

Page 1: ...mage electrical wiring and other hidden utilities CAUTION TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR BE SURE TO DUCT AIR OUTSIDE DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILING...

Page 2: ...ct ceiling height distance mounted from cooking surface cabinet or soffit heights along with other factors and will need to be adjusted accordingly The hood must be mounted a minimum of 24 and a maxim...

Page 3: ...installed it must be installed before the hood canopy because the hood canopy will cover the backsplash mounting screws Refer to the instructions included with the backsplash for complete installation...

Page 4: ...ach dry wall or secure the hood If this is your situation Air King recommends that you hire a professional and comply with all applicable codes 8 Install the proper sized outlet adapter available sepa...

Page 5: ...stat Your hood is equipped with a thermostat that will automatically turn the hood on when the temperature exceeds a set point Once the temperature drops the thermostat will turn the hood off CAUTION...

Page 6: ...oducts to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WIT...

Page 7: ...38730 1 Internal Panel 36 models 5S1138740 7 REPLACEMENT PARTS DIAGRAM 18 MODELS Qty Description Replacement Part 11 1 Sub Wire Harness without Heat Lamp 5S1138007 1 Sub Wire Harness with Heat Lamp 5S...

Page 8: ...late 5S1142010 10 2 Knob 5S1142011 REPLACEMENT PARTS DIAGRAM 10 MODELS Qty Description Replacement Part 11 1 Internal Panel 30 models 5S1138430 1 Internal Panel 36 models 5S1138440 12 1 Sub Wire Harne...

Page 9: ...TISSEMENT POUR R DUIRE LES RISQUES D INCENDIE ET POUR VACUER L AIR AD QUATEMENT ASSUREZ VOUS D VACUER L AIR VERS L EXT RIEUR NE PAS VACUER L AIR DANS DES ESPACES DANS LES MURS LES PLAFONDS OU LES GREN...

Page 10: ...ce de cuisson de la hauteur de l armoire ou du soffite ainsi que d autres facteurs et doivent tre ajust es en cons quence La hotte doit tre mont e un minimum de 24 po et un maximum de 36 po cm de la s...

Page 11: ...ce avec les vis comprises Assurez vous que le joint est tanche autour de l adaptateur en s curisant tous les raccords avec du ruban de gaine Figure 7 REMARQUE Si le dosseret facultatif recommand de la...

Page 12: ...re et une assise pour transf rer la charge aux montants adjacents Des montants additionnels pourraient devoir tre b tis dans l ouverture pour fixer la cloison s che et pour fixer la hotte Si vous renc...

Page 13: ...du bas Thermostat Votre hotte est quip d un thermostat qui allumera automatiquement le hotte quand la temp rature d passe un point d termin Une fois que la temp rature s abaisse le thermostat teindra...

Page 14: ...d exp dition pour le retour des produits Air King pour la r paration ou le remplacement Air King payera les frais d exp dition de retour de Air King apr s les r parations ou le remplacement de garanti...

Page 15: ...tique 5S1142010 9 2 Boutons 5S1142011 10 1 Internal Panel 30 models 5S1138730 1 Internal Panel 36 models 5S1138740 de pi ce Qt Description de remplacement 11 1 Harnais de sous c blage sans 5S1138007 l...

Page 16: ...d clairage 5S1141013 TABLEAU DES PI CES DE RECHANGE MOD LES DE 10 PO de pi ce Qt Description de remplacement 9 1 Plaque signal tique 5S1142010 10 2 Boutons 5S1142011 11 1 Mod les de 30 po panneau inte...

Reviews: