6
1. Follow all cleaning instructions prior to storage.
2. Dry all parts, including the inside of the Water Tank.
3. Preferably store in its original box, in a dry place away from high temperatures.
4. Follow all cleaning instructions after long periods of storage.
Storage
Weekly Cleaning & Care
WARNING:
Before cleaning always turn power off and unplug the unit from outlet.
WARNING: DO NOT
rinse Base under faucet. To clean, wipe the Base with a soft cloth.
WARNING: DO NOT
use any solvents or aggressive cleaning agents. Keep water away from the Air Outlet.
WARNING: DO NOT
tamper with the Water Sensor.
About White Dust -
Use of high mineral content water may cause a white mineral residue to accumulate on room surfaces
near the humidifier. The mineral residue is commonly referred to as “White Dust”. The higher the mineral content (the harder
your water), the greater the potential for White Dust. The White Dust is not caused by a defect in the humidifier, but is due only
to minerals suspended in the water from your tap.
WARNING
: If you have hard tap water use our Humidifier
Demineralization Filters (available at
www.Air-Innovations.com
) or use ONLY filtered/distilled water.
Tank Cleaning -
Unplug unit & remove the Mist Nozzle from the top of the Water Tank then remove the Water Tank and Lid
from the unit.
Turn the tank upside down and drain any water from the tank. Wipe the tank with a soft damp cloth then rinse it
with warm water inside and out.
Base Cleaning
1. Unplug unit.
2. Use enclosed Silicone Plug and place over water inlet (see below 1/a 1/b).
3. Clean the Base by gently wiping with a soft damp cloth.
Using Silicone Plug
Please apply the enclosed plug during cleaning
ONLY
in order to avoid
debris from entering the pump.
NOTE:
the plug
MUST
be
REMOVED
for normal operation and filling.
White Dust Cleaning
- If mineral deposits “White Dust” are evident
around the Ultrasonic Nebulizer
a
and Water Sensor, clean these surfaces
with a soft cloth and a small amount of undiluted white vinegar.
If necessary, mix a solution of 50% white vinegar and 50% water
and fill the Base with enough solution to cover the Ultrasonic
Nebulizer
a
. Allow it to soak for an hour and then use the provided
brush to gently loosen buildup on the Ultrasonic Nebulizer
b
.
Pour 1 cup of water in the Base and wipe clean with a soft cloth.
WARNING: DO NOT
rinse Base under faucet.
WARNING:
When emptying the Water Reservoir in the Base,
make sure that the water is poured away from the Air Outlet
c
.
If water is poured into the outlet it may damage the humidifier.
Ceramic Water Filter Cleaning
1. Unplug unit and empty water from Tank.
3. Remove the Water Tank Lid and place hand inside the Tank and moderately grasp
the Ceramic Water Filter and unscrew by twisting counterclockwise
d
.
Rinse the Ceramic Filter with running tap water for approx 20-30 seconds
e
.
Then replace filter inside Water Tank by twisting clockwise until secure
f
and replace the lid.
Surface Cleaning -
Clean all surfaces of the unit with a clean damp soft cloth
.
a
b
c
d
e
f
1a
1b
f
g
h
i
Replacing The Remote Control Battery -
Push the tab to the left of the
battery tray towards the right to unlock the tray.
f
While the the tab is pushed,
pull out the battery tray.
g
Remove the battery from the tray and replace it with
a new 3 volt lithium battery (CR2025) with the positive side facing up.
h
Insert
the tray back into the bottom of the remote contol until it locks in.
j