Air Fantastic CAP3000 Owner'S Manual Download Page 3

Important Safety Instructions

When operating any electrical appliance, basic precautions should always be fol-

lowed for safety. 

 RISK OF FIRE, ELECTRIC SHOCK, OR INJURY

•  Carefully read the entire contents of this manual.

•  Do not use outdoors, in moist areas or on wet surfaces.

•  Do not use the unit in areas of extreme heat or in the pres-

ence of flammable gas.

•  Do not allow any foreign objects to enter the ballast cooling 

vents. 

•  Do not attempt to service or repair the unit yourself. Any 

attempt to repair the unit yourself could cause serious injury 

and will void the warranty.

•  Do not handle the plug or appliance with wet hands.

•  Do not pull on power cord to unplug. To unplug grasp the plug, not the cord.

•  Do not use with damaged power cord or plug. If appliance is not working prop-

erly, has been dropped, damaged, left outdoors, or dropped into water, call a 

customer service representative at 1-877-424-7326.

WARNING:  RISK  OF  ELECTRICAL  SHOCK.  CAN  CAUSE  INJURY  OR  DEATH. 

UNPLUG OR DISCONNECT UNIT FROM POWER SUPPLY BEFORE SERVICING.

 

Store and transport -4˚ F ~ 180˚ F, humidity 10% ~ 90% (Non Condensing).

 Do not operate unit in ambient temperatures above 150˚ F.

 

KEEP OUT OF REACH OF CHILDREN

 Only use the power adapters included with the purification system.
WARNING: UV LIGHT HAZARD. 

Harmful  to  skin  and  eyes.  Can  cause 

temporary or permanent loss of vision. 

Never look at the lamp while illuminated. 

To prevent exposure to ultraviolet light, 

be sure the power is disconnected until 

installation is completed and before ser-

vicing.  

UV  lamps  contain  Hg  (Mercury). 

High or long term exposure to Hg can lead to serious health risks. UV lamps should 

be disposed of according to disposal laws in your area. UV lamps should never 

be disposed via standard waste receptacles. They often break when thrown into a 

dumpster, trash can or compactor, or when they end up in a landfill or incinerator. 

Learn  more  about  proper  disposal  methods  and  find  disposal  centers  at  www.

earth911.org.

Never touch UV lamp with bare hands. Oils from your skin can create hot 

spots causing UV lamp to break when illuminated.

Never remove the outer housing of any components.

Cooling Vents

WARNING

OPTICAL RADIATION EXPOSURE HAZARD

DO NOT ATTEMPT TO OPERATE UNIT WITHOUT 

PROPERLY INSTALLING UNIT FIRST.

PERMANENT EYE  AND SKIN DAMAGE MAY RESULT.

1

Summary of Contents for CAP3000

Page 1: ...ral Air Purifier CAP Owner s Manual For use with Models CAP3000 CAP5000 For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit Air Fanta...

Page 2: ...lease contact us Mail Air Fantastic LLC Attn Customer Service 4406 Eagles Landing Dr Austin TX 78735 Web www airfantastic com E mail markm airfantastic com Phone 1 877 424 7326 Important Safety Instru...

Page 3: ...4 F 180 F humidity 10 90 Non Condensing Do not operate unit in ambient temperatures above 150 F KEEP OUT OF REACH OF CHILDREN Only use the power adapters included with the purification system WARNING...

Page 4: ...ld bacteria virus es and VOCs Proprietary UVC Lamps At the core of the Quad Ion Cell is a UVC lamp The 254 nm germicidal lamp kills mold bacteria viruses and breaks down VOCs They are American made la...

Page 5: ...mps Induct Quad Ion Cell CAP System devices are intended for the removal of air borne contaminations of pathogens and or harmful molds and volatile organic compounds present in rooms or en closed area...

Page 6: ...still red please contact an Air Fantastic representative Lamp Replacement Indicator Blue Solid The UVC lamp is within its two year life span No action is needed Blue Flashing The UVC lamp is outside...

Page 7: ...ing premature system failure Air Fantastic has designed the perfect solution With the development of our proprietary Rotational UV Shield you can control how little or how much UV light is emitted fro...

Page 8: ...running parallel with the duct ensuring air flow through the device When possible the UV Shield should be rotated the open position for optimal efficiency to expose more contaminants to UVC radiation...

Page 9: ...yourself or others if you elect to install the device without utilizing qualified technicians Use the suggestions on page 6 to determine the optimal mounting location s To complete the installation pr...

Page 10: ...four pins are in line with the Four Pin Connector Before inserting the CAP System use a 1 4 hex head screw driver to remove the four outer screws and pull off the Ballast Assembly from the Retainer Ri...

Page 11: ...sive gasket will help secure the unit but the four hex screws are still required to secure the Ballast Assembly 7 Using a 1 4 hex head screw driver secure the power adapter with four self tapping 1 2...

Page 12: ...Lamp Replacement light will begin to blink as a reminder that it s time to replace the Quad Ion Cell The CAP System utilizes a proprietary UVC lamp that can only be purchased from an authorized Air F...

Page 13: ...until the four pins have completely disconnected from the Ballast Assembly 3 Using a 1 4 hex head screw driver remove the four screws securing the Quad Ion Cell and pull the Quad Ion Cell out from the...

Page 14: ...allast Assembly should be orientated with the air flow label running parallel with the length of the duct to ensure the four pins are in line with the Four Pin Connector Optional mounting config urati...

Page 15: ...dealer your purchase is AS IS which means Air Fantastic grants you no warranty and that you not Air Fantastic assume the entire risk of the quality and performance of this product including the entir...

Page 16: ...rs since the Quad Ion Cell has been replaced Contact an Air Fantastic authorized dealer to purchase a new Quad Ion Cell If the above does not repair the symptom please contact an Air Fantastic Cus tom...

Reviews: