Air Conditioning Centre KYR-25CO/AG User Manual Download Page 16

 

16 

 

 

Fig.8 

 

7.2 Introduction to Exhaust Hose Installation

 

                   

 

Fig.9 

 

Temporary installation   

1. 

Twist the housing adaptor and fix the window Connector to the end of the exhaust hose. 

2. 

Insert  the  fixing  clip  of  the  housing  adaptor  into  the  openings  at  back  of  the  air 
conditioner.   

3. 

  Put the other end of the exhaust hose to the nearest window (

see Fig.9

). 

 
Window Kit Installation   

The installation manner of window slider kit is mostly in 

“horizontal” or “vertical”. As     

shown

 Fig.10

 and 

Fig.10a

, check the min. and max. size of the window before the installation. 

1. Install the window kit on the window (

Fig.10, Fig.10a

); 

2. Adjust the length of the window slider kit according to the window width or height, and fix it with   

the dowel; 

3. Insert the window connector of the hose to the hole of the window kit 

(Fig.11)

.   

 

Summary of Contents for KYR-25CO/AG

Page 1: ...1 Portable Air Conditioning User s Manual For Models KYR 25CO AG KYR 35GW AG KYR 45GW AG KYR 55GW AG Please read this user manual carefully to ensure proper use maintenance and installation...

Page 2: ...2...

Page 3: ...Name of Parts 5 3 Accessories 6 4 Appearance and Function of Control Panel 7 5 Appearance and Function of Remote Control 11 6 Operation Introduction 9 7 Installation Explanations 12 8 Maintenance Exp...

Page 4: ...ously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Be aware the refrigerants may not contain an odour Appliance s...

Page 5: ...riate certification issued by an accredited organization that ensures competence in handling refrigerants according to a specific evaluation recognized by associations in the industry Repairs must be...

Page 6: ...supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made...

Page 7: ...Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants 22 Do not operate or...

Page 8: ...off the power switch and disconnect the power supply It must be replaced by the dealer or a designated repair shop 2 Name of Parts Fig 1 1 Louver 6 Drainage outlet 2 Control panel 7 Air outlet 3 Front...

Page 9: ...Window Connector 1 Housing adaptor 1 Remote Controller 1 Window Kit 1 Remote Controller 1 optional Window Connector 1 optional Window Kit 1 optional Air outlet 1 optional Dowel 2 optional Universal W...

Page 10: ...s manual 4 Appearance and Function of Control Panel Cooling Heat pump model WIFI A Power on off 3 Dehumidifying B Fan speed 4 Fan C Temperature up 5 Heating D Temperature down 6 WIFI function E Operat...

Page 11: ...remote controller in a location exposed to direct sunlight Do not submerge the remote control in any liquids 1 POWER Power on off 2 TIMER Timer on off 3 MODE Operation MODE 4 TEMP Temperature down 5 T...

Page 12: ...earby 2 As shown in Fig 5 and Fig 5a install the exhaust hose and adjust the window position well Fig 5 Fig 5a 3 Connect drain hose well only for use during heating mode not KYR25CO 4 Insert the power...

Page 13: ...ng keep an interval of at least 3 minutes between each ON OFF Power supply must meet the requirements The socket is for AC use Do not share one socket with other appliances Power supply is AC220V 240V...

Page 14: ...ns on press this key the louver will swing continuously left and right by pressing this button again the movement will stop and the louver will remain in that position Some models 6 8 SLEEP mode While...

Page 15: ...5s this enters the WIFI factory set up mode The unit is connected with WIFI if the WIFI indicator LED is on otherwise it is not connected When the WIFI indicator is flashing slowly the unit is in the...

Page 16: ...the exhaust hose to the nearest window see Fig 9 Window Kit Installation The installation manner of window slider kit is mostly in horizontal or vertical As shown Fig 10 and Fig 10a check the min and...

Page 17: ...17 Fig 10 Fig 10a Fig 11 Universal window kit accessory for mobile air conditioner Suitable for windows and doors Included in this kit 1 piece of zipped fabric 1 roll of hook and loop adhesive tape...

Page 18: ...nner surface of the window flap on the handle side 3 Stick the widest side A of the large white fabric piece to the window frame and then stick the narrower side B to the window leaf handle side from...

Page 19: ...d when the water is full please remove the rubber bung stopper at the bottom of unit and all water will be drained outside 5 Open the window gently and open the zipper of the fabric piece at level of...

Page 20: ...ing be sure to disconnect the unit from any electric supply outlet 2 Do not use gasoline orother chemicals to clean the unit 3 Do not wash the unit directly 4 If the conditioner is damaged please cont...

Page 21: ...ry it in the shade Mounting Put the air filter into the inlet grille replace the components as they were 8 2 Clean the Air conditioner Surface First clean the surface with a neutral detergent and wet...

Page 22: ...lean the air inlet 3 Noisy The ground is not level or not flat enough Place the unit on a flat level surface if possible Sound comes from the flowing of the refrigerant inside the air conditioner It i...

Page 23: ...port Portal You can register your Warranty or Open a SupportTicket at support airconditioningcentre com Email support airconditioningcentre com Tel 03703 344 345 Air Conditioning Centre is a division...