Page 4
RY-1824L Instr.
0519
SPECIFICATIONS:
Power Source:
Supplied by master station or CEU
Mounting:
No mounting required
Terminations:
Color-coded prewired pigtails
Relay Input:
18~24V DC, Red and Black wires, 22AWG
Relay Output:
Brown, Yellow, Orange wires, 18AWG
Output rating:
8A at 250V AC, 5A at 30V DC
Wiring:
2 conductors from station’s door release contacts to RY-1824L
2 conductors from RY-1824L to release mechanism, with power wired in series
Dimensions (HxWxD): 1-7/16" x 13/16" x 7/16", with wires extending approx. 7-1/2"
D1 D3 D5 D7
D2 D4 D6 D8
DOOR RELEASE RELAY
L1 L2 L3 L4 L5 L6 L7 L8
M1 M3
M2 M4
VCH1 VCH2
X1 OUT X2
AX-320C
CO
+ - + -
D-PS V-PS
RS-232C
POWER
VIDEO OUT
V1 V2
AIPHONE
AX-084C
AX-8MV
AX-DV
+
-
+
-
Connect separate RY-1824L relay for each door release contact being used.
WIRING DIAGRAMS (cont):
AX-DV
AX Series Wiring
Re
d
Blk
Brn
Org
Yel
COM
N/O
Use Brown and Orange wires
when connecting to electric strike
LOCK
POWER
Re
d
Blk
Brn
Org
Yel
COM
N/C
Use Brown and Yellow wires
when connecting to maglock
LOCK
POWER
NOTE: The door release contacts are rated at 24V AC/DC,
500mA. The RY-1824L should be used in any application where
the strike or maglock has a higher voltage or draws more current.
Otherwise, internal damage to the Exchange Unit could occur.
Aiphone Corporation
www.aiphone.com
[email protected]
(800) 692-0200
PS-2420UL
PS-2420UL
RY-1824L
RY-1824L