background image

Individual Components for NDR-LD System:

NDR-n-LD

Master station (10, 20, 30, 40-station) for Long Distance

IE-JA-NLD

Flush mount long distance sub with stainless steel cover

IF-DA-NLD

Surface mount long distance sub, brown plastic

PC-359B

Call holding circuit board for sub station, mounted externally

PS-2410A:

24V DC Power Supply (for 10 and 20 station masters)

PS-24E:

24V DC, 2A Power Supply (for 30 and 40 station masters)

SUB STATION MOUNTING:

IE-JA-NLD:

2-gang electrical box

IF-DA-NLD:

Surface mounts to 1-gang box

- INSTRUCTIONS -

The NDR-LD Long Distance Lamp Memory System is designed for communication with remote stations
located up to 4,000' away, or to each elevator in a building.  Sub stations are available in surface or
flush mount styles, and require a separate circuit board (PC-359B) to be added for the call-in function.
Three wires are required to each sub station. One RY-PA is required per contact closure. Additional
wires are required for extra contacts to activate external devices.

NDR-LD

NDR CCTV Call Up and Door Release System for Long Distances and Elevators

NDR-n-LD Master Station

IF-DA-NLD and IE-JA-NLD Sub Stations

Special
Order
Products

Pg. 1

WIRING DIAGRAM:     SYSTEM USED FOR CCTV CAMERA CALL-UP

1

2

2

3

4

5 6

7

7

7

7

8

9

PC-359B (Solder side view)

Solder pads:
Numbered by
location on
board.

To 1
To 2

To Blk
To Blk

1

          L

2

RY-PA

#1

BLK

H

RY-PA

#2

NDR-LD Master

RY-PA

#1

RY-PA

#2

BLK

BLK

BLK

YEL

Momentary closure #1

YEL

Constant closure #1

YEL

Momentary
closure #2

YEL

Constant
closure #2

Equipment for each station that requires
both a constant closure and momentary
closure when a channel is selected:
2 RY-PA relays
1 Diode (1N4001)

DUAL FUNCTIONS FROM EACH CHANNEL:

Terminal Block

NDR-LD TERMINAL DEFINITIONS:

+

Positive 24V DC

-

Negative

1~40

Station number

E

Common communication

H

Provides power to sub station

Normally Open contacts remain
closed as long as master has sub
station selected.

NDR-20-LD

+

-

PS-2410A

External

Terminal Block

1
2
~

20

L

Closure for Station #2

BLK

YEL

Closure for Station #1

RY-PA

#1

BLK

YEL

RY-PA

#3

1
2
2

3
4
5
6
7
7
7
7
8
9

PC-359B

IF-DA-NLD

1

2

Blk
Blk

WHT

Wire

1
2
3
~

20

E

H

+

-

IE-JA-NLD

1

2

Blk
Blk

3

1
2
2

3
4
5
6
7
7
7
7
8
9

PC-359B

Reviews: