OPERATION:

1.  When a sub station places a call, the red channel LED indicator lights and a call tone rings at the master.  The
     tone and light will remain activated until the call is answered, which is the primary function of the PC-359B.  The

     LED indicator at the sub station will be lit from the time the call is placed until it is answered.

2.  If the master station is talking to another sub station, a new call from another sub station will light the LED, but
the

     call tone will not be heard.

3.  When the call is answered, the LED on the master goes off.  The person at the master uses the push-to-talk,
     release-to-listen button, or picks up the handset to speak (with NEM-A masters). The LED at the sub station will
go

     off when the master answers.

4.  When the conversation is completed, the OFF button to the left of the station selector button must be pressed to
     disengage the call.

SPECIFICATIONS:

Power Source:

24V DC at master.  Use PS-2410A or PS-24E.

Communication Output:

500mW at 20 ohms

Communication:

Push-to-talk, release-to-listen or VOX handset at master.
Hands free at sub station.

Calling:

Master to sub:  By voice only after pretone.
Sub to master:  Call tone and LED, remaining activated until call is answered.

Wiring:

2 common plus 1 individual per sub, looped; or 3 conductors homerun to each sub.
Shielded cable is recommended.
Use Aiphone #822203 for homerun wiring, #822206 for 4 stations

on each run, or #822210 for up to 8 stations on each run.

Wiring Distance:

2,000' with 22AWG; 4,000' with 18AWG.

Dimensions (H x W x D):

IE-JA-NLD:  4-1/2" x 4-9/16" x 1-9/16"
IF-DA-NLD: 5-1/8" x 3-7/8" x 1-1/8"

Pg. 2

NDR-LD Instr.

1198bkjd

TOLL FREE TECHNICAL SUPPORT:

(800) 692-0200

TOLL FREE FAX LINE:

(800) 832-3765

TECHNICAL SUPPORT E-MAIL:

[email protected]

Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA  98005
(425) 455-0510
FAX (425) 455-0071

Normally Open contacts
are maintained when the
door release button is being
pressed while a station
button is selected.

To convert RY-PA to N/C
(normally closed) contact,
Move one yellow wire from
"NO" to "NC".  (Internal
connection, soldering
required.)

To activate
door release,
press button
located above
TALK button.

WIRING DIAGRAM:     SYSTEM USED FOR SELECTIVE DOOR RELEASE

NDR-20-LD

+

-

PS-2410A

External

Terminal Block

1
2
~

20

L

Closure for Station #2

Closure for Station #1

BLK

YEL

RY-PA

#1

BLK

YEL

RY-PA

#2

1
2
3
~

20

E
H

+

-