PRECAUTIONS

General Prohibitions   

Prohibition to Dismantle the Unit   

Prohibition on Subjecting the Unit to Water   

General Precautions

WARNING

(Negligence could result in death or serious injury.) 

1.  High voltage is present internally. Do not open the case. Electric shock could result.
2.  Do not dismantle or alter the unit. Fire or electric shock could result.
3.  Do not connect any non-specified power source to the +, - terminals. Also, do not 

install two power supplies in parallel to a single input. Fire or damage to the unit 
could result.

4.  Keep the unit away from water or any other liquid. Fire or electric shock could result.
5.  Do not put any metal or flammable material into the unit through the openings. Fire 

or electric shock could result.

6.  Do not use power supply with a voltage other than specified. Fire or electric shock 

could result.

7.  Do not connect any terminal on the unit to an AC power line. Fire or electric shock 

could result.

CAUTION

(Negligence could result in injury to people or damage to property.)

1.  Do not install or make any wire terminations while power supply is plugged in. It 

can cause electrical shock or damage to the unit.

2.  Before turning on power, make sure wires are not crossed or shorted. If not, fire or 

electric shock could result.

3.  When mounting the unit on a wall, install the unit in a convenient location, but not 

where it could be jarred or bumped. Injury could result.

4.  For power supply, use Aiphone power supply model or model specified for use 

with system. If non-specified product is used, fire or malfunction could result.

5.  Do not install the unit in any of the following locations. Fire, electric shock, or unit 

trouble could result.

*  Places under direct sunlight or places near heating equipment that varies in 

temperature.

*  Places subject to dust, oil, chemicals, etc.
*  Places subject to moisture and humidity extremes, such as bathrooms, cellars, 

greenhouses, etc.

*  Places where the temperature is quite low, such as inside a refrigerated area or in 

front of an air conditioner.

*  Places subject to steam or smoke (near heating or cooking surfaces).
*  Where noise generating devices such as dimmer switches or inverter electrical 

appliances are close by.

*  Do not install the unit in locations subject to frequent vibration or impact.
6.  Do not put anything on the unit or cover the unit with cloth, etc. Fire or unit trouble 

could result.

7.  Do not press on the LCD or subject it to a high impact. The LCD glass could be 

punctured and result in an injury.

8.  If the LCD is punctured, do not allow skin contact with the liquid crystal inside. 

Inflammation could result.

*  If liquid crystal is ingested, immediately gargle with water and seek medical 

attention.

*  If contact with the eyes or skin occurs, clean with pure water for at least 15 minutes 

and seek medical attention.

General Precautions

1.  Keep the unit more than 1 m away from radio or TV set.
2.  This unit is for indoor use only. Do not use outdoors.
3.  In areas where broadcasting station antennas are close by, the intercom system may be 

affected by radio frequency interference.

4.  As to other manufacturer's devices (such as sensor, detectors, door releases) used 

with this system, comply with the Specifications and Warranty conditions that the 
manufacturers or venders present.

5.  Keep the intercom wires at least 30 cm (12") away from AC 100-240 V lines. Noise 

and malfunction could result.

6.  If the unit is down or does not operate properly, unplug the power supply or turn off 

the JK-1MED and JK-1HD (JK-1SD) POWER switches.

7.  The unit is for wall-mount use only. For desktop applications, use desk stand.
8.  When wall-mounted, the top of the unit may darken. This does not indicate a 

malfunction.

9.  The unit case may become warm with use, but this is not a unit malfunction.
10.  If a cellular phone is used close by, the unit may malfunction.
11.  The LCD panel is manufactured with very high precision techniques. Small portions 

of the panel may fail to light up or some portions may be constantly lit, but this does 
not indicate a unit malfunction. Please be aware of this in advance.

12.  Refrain from using the color monitor station in sunlit areas.
13.  At night, due to reduced lighting on the object, the monitor sees more noise and the 

face becomes more difficult to see, but this is not malfunction.

14.  Talk within 50 cm (20") or less from the unit. If you stand too far away, it may be 

difficult for the other person to hear the communication.

15.  If there are loud noises around the unit (such as music playing or children crying), the 

sound may break up and be difficult to hear.

16.  During communication, if you speak before the other person has finished talking, your 

voice may not come through clearly. Communication will proceed smoothly if you 
wait until the other person has finished before speaking.

17.  At a gate or porch illuminated by a fluorescent lamp, the picture may vary, but this is 

not a malfunction.

18.  When outside temperature lowers sharply after rainfall, etc., the inside of the camera 

may fog up slightly, causing a blurry picture, but this is not a malfunction. Normal 
operation will be restored when moisture evaporates.

19.  Due to the environmental sound around the unit, it may hinder smooth communication, 

but this is not a malfunction.

20.  The outline of video images displayed by video door station may differ from that of 

the actual person(s) or background, but this is not a malfunction.

21.  If the screen of a video door station freezes during wintertime, the picture may become 

difficult to see or the CALL button may not move, but this is not a malfunction.

22.  Aiphone assumes no responsibility for corruption of saved information (such as 

changes to or deletion of saved information). Please be aware of this in advance.

23.  This unit is not compatible with JA, JF, KB, and KC series units.
24.  Warm-color lighting shining on the door station may change the tint of the picture on 

the monitor.

  1 

PACKAGE CONTENTS

JK-1MED

Mounting screws x 2

Wood mounting screws x 2

Option connector

Installation & Operation manual

Summary of Contents for JK-1MED

Page 1: ...ION INTERPHONEVIDEO COULEUR MAINS LIBRES MONITEUR MA TRE HANDENVRIJE KLEURENVIDEOFONIE MONITOR HOOFDPOST JK 1MED Master monitor station Moniteur ma tre Monitor hoofdpost INSTALLATION OPERATION MANUAL...

Page 2: ...is for indoor use only Do not use outdoors 3 In areas where broadcasting station antennas are close by the intercom system may be affected by radio frequency interference 4 As to other manufacturer s...

Page 3: ...n 5 cm 2 5 cm 2 JK 1MED 2 3 15 cm 6 2 2 Wiring method wiring distance Wire the units from station to station daisy chained 0 65 mm 22 AWG 1 0 mm 18 AWG A 50 m 165 100 m 330 B 5 m 16 10 m 33 C 75 m 245...

Page 4: ...EL 12S AC 12 V 0 125 A DC 12 V 0 2 A or equivalent part and a separate AC transformer are required Run separate cables for audio video and door release Door release contact AC DC 24 V 0 5 A Minimum C...

Page 5: ...master monitor station Audio only sub master station Optional long distance adaptor JKW BA Use the long distance adaptor JKW BA within the distance ranges shown in the table when the wiring distance b...

Page 6: ...1 gang box Din rail 83 5 mm 3 5 16 To pass the cable through the back of the unit cut out the cable inlet Wood mounting screws x 2 Mounting bracket 83 5 mm 3 5 16 5 NAMES JK 1MED Play LED red PLAY but...

Page 7: ...ettings are incomplete start again from the beginning Symbol Function description To manually record To return to the screen of the previous operation To display the previous more recent date picture...

Page 8: ...The date time increases by one button press once The date time decreases by one button press once The cursor moves to the left button pressed once The cursor moves to the right button press and hold f...

Page 9: ...creen 7 5 1 Setting the optional units detection method Initial setting 1 After performing steps 1 and 2 in section 7 1 select EXT INPUT and press MENU button 2 In the EXTERNAL INPUT SETTING screen pr...

Page 10: ...pictures are erased and settings are reset 2 Pre set functions section 8 7 are not reset Settings reset with RESTORE DEFAULT SETTING Setting name Available setting Time JAN 01 2009 00 00 Language ENG...

Page 11: ...pictures at a pre set position and the next three pictures are wide pictures Pictures are automatically recorded First three pictures are wide pictures and the next three pictures are zoom pictures at...

Page 12: ...play changes ZOOM WIDE button section 8 5 can be used to change the display 3 When TALK button is pressed momentarily and communication starts the screen display will be held as is regardless of the p...

Page 13: ...ton to talk with the other person A call in is sent to the sub master station The reply of the other person is not heard 2 If the other person presses TALK button hands free communication is possible...

Page 14: ...ng again The previous setting will be overwritten 2 The zoom picture position set with the master monitor station will also be displayed at the sub monitor station 2 Press ZOOM WIDE button for at leas...

Page 15: ...utomatic recording function cannot be cancelled 2 The recorded pictures are recorded using the method section 7 10 that has been set However if switching between zoom and wide is performed during auto...

Page 16: ...age Refer to sections 8 13 and 8 14 1 When there are multiple unread images all images enter the read condition even if only one image is played and the play LED goes off 2 The recorded pictures are d...

Page 17: ...dysfonctionnement d un de ses produits La zone d application de est l UE Garantie Aiphone garandeert dat zijn producten onder normale gebruiksomstandigheden gedurende twee jaar na levering aan de eind...

Reviews: