Aiphone IS-IPRY8 Programming Manual Download Page 6

6 | IS-IPRY8 Programming Manual

Output Relay Programming (cont.)

Relay Functionality:

Enter the TermID for the door station associated to the relay (see page 4 for TermID defi nition). 
Select the relay action from the drop down menu. 

Relay Action options:
• 

Door Release - Normally-open

• 

Door Release - Normally-closed

• 

Active while Calling from source

• 

Active while in Communication with source

• 

Active during Calling and Communication

When the relay actions are set for the “door release” options, the relay will trigger when the associated door 
station is in communication, but only when the “confi gured” master station pushes the door release button.
When the relay actions are set for any of the “active while/during” options, the relay will trigger when the 
associated door station calls or communicates at any priority level.

After the Door TermID and Relay Action has been set, click 

Apply Settings

 at the bottom of the screen to 

save the settings to memory. Return to the application screen or reboot adaptor by clicking on the 

Reboot

 

button. Rebooting must occur to update adaptor settings.

To program a master station to control door release, click on the 

Confi gure

 button. A new window will open 

and the table shown below will be populated based on the entries made in the Linked Stations Table (see 
page 5). Check the 

Flag

 box beside each master station that will be “allowed” to trigger this relay for door 

release. Once all masters have been checked, click 

Apply Settings

 at the bottom of this window to save 

the settings to memory. Reboot to update adaptor settings.

Note:

 

Only IS-IPMV masters can be enabled for door release using the IS-IPRY8.

Relay will trigger when the master station pushes the door 
release button.

Relay will trigger when the associated door station 
calls or communicates.

}

}

Summary of Contents for IS-IPRY8

Page 1: ...is the programming manual for the IS IPRY8 only Refer to the IS Series IP Network Direct Installation and Setting Manuals for complete information on IS IP components 0313 Input Output Adaptor for the...

Page 2: ...required Use the Aiphone PS 1225UL power supply sold separately SIF INI File In order for the IS IP video door stations and master stations to communicate with the adaptor a SIF INI text file must be...

Page 3: ...w window will open F Click the Browse button and navigate to the txt file saved on the PC G Click the Upload button A message will appear stating the settings will not be applied until the system is u...

Page 4: ...guration It also distinguishes between master station units and door station units Master stations TermID will be xx 001 and door stations Term ID will be xx 101 xx represents the line in which the st...

Page 5: ...ini txt file created see page 2 If 0 is entered in SIF Socket Local Port the default port 10000 will be used Enter the IS Series Access Username and Password for the system Default Username aiphone De...

Page 6: ...any priority level After the Door TermID and Relay Action has been set click Apply Settings at the bottom of the screen to save the settings to memory Return to the application screen or reboot adapt...

Page 7: ...vel and target IP address have been set click Apply Settings at the bottom of the screen to save the settings to memory Return to the application screen or reboot adaptor by clicking on the Reboot but...

Page 8: ...er use proper power for the strike mag lock or external signaling device being used PS12 PT PT R2 NO R4 NO R1 NO R3 NO R2 NO R4 NO I1 I2 G G I3 I4 Input 1 Input 2 Input 3 Input 4 Ground Relay 1 Relay...