6 | IS-IPRY8 Programming Manual
Output Relay Programming (cont.)
Relay Functionality:
Enter the TermID for the door station associated to the relay (see page 4 for TermID defi nition).
Select the relay action from the drop down menu.
Relay Action options:
•
Door Release - Normally-open
•
Door Release - Normally-closed
•
Active while Calling from source
•
Active while in Communication with source
•
Active during Calling and Communication
When the relay actions are set for the “door release” options, the relay will trigger when the associated door
station is in communication, but only when the “confi gured” master station pushes the door release button.
When the relay actions are set for any of the “active while/during” options, the relay will trigger when the
associated door station calls or communicates at any priority level.
After the Door TermID and Relay Action has been set, click
Apply Settings
at the bottom of the screen to
save the settings to memory. Return to the application screen or reboot adaptor by clicking on the
Reboot
button. Rebooting must occur to update adaptor settings.
To program a master station to control door release, click on the
Confi gure
button. A new window will open
and the table shown below will be populated based on the entries made in the Linked Stations Table (see
page 5). Check the
Flag
box beside each master station that will be “allowed” to trigger this relay for door
release. Once all masters have been checked, click
Apply Settings
at the bottom of this window to save
the settings to memory. Reboot to update adaptor settings.
Note:
Only IS-IPMV masters can be enabled for door release using the IS-IPRY8.
Relay will trigger when the master station pushes the door
release button.
Relay will trigger when the associated door station
calls or communicates.
}
}