A.  Open a web browser and type 

https://192.168.0.40/sif 

in the address bar.

B.  A security certifi cate error message will appear. Continue to the website.

C.  Enter the administrator ID and password. 

 

 

 

 

 

 

 

Default ID:     

aiphone

 

 

 

 

 

 

 

Default Password:   aiphone

D.  Select 

Transmission setting

 under “Uploading SIF setting data” from the menu on the left side of the screen.

E. Click the 

Upload

 button. A new window will open.

F. Click 

the 

Browse

 button and navigate to the .txt fi le saved on the PC.

G. Click the 

Upload

 button. A message will appear stating the settings will not be applied until the system is 

updated.

H. Click 

Updating the system

 from the menu on the left. Click the 

Update

 button and the unit will update 

and restart itself.

I.  Repeat this process for each IS-IP door and master station to be associated with the IS-IPRY8 adaptor.

The SIF / INI text fi le must be uploaded to each IS-IP device associated with the IS-IPRY8 adaptor. 
  !  

Note that the IP address for each IS-IP unit will be unique for your network settings.

Summary of Contents for IS-IPRY8

Page 1: ...is the programming manual for the IS IPRY8 only Refer to the IS Series IP Network Direct Installation and Setting Manuals for complete information on IS IP components 0313 Input Output Adaptor for the...

Page 2: ...required Use the Aiphone PS 1225UL power supply sold separately SIF INI File In order for the IS IP video door stations and master stations to communicate with the adaptor a SIF INI text file must be...

Page 3: ...w window will open F Click the Browse button and navigate to the txt file saved on the PC G Click the Upload button A message will appear stating the settings will not be applied until the system is u...

Page 4: ...guration It also distinguishes between master station units and door station units Master stations TermID will be xx 001 and door stations Term ID will be xx 101 xx represents the line in which the st...

Page 5: ...ini txt file created see page 2 If 0 is entered in SIF Socket Local Port the default port 10000 will be used Enter the IS Series Access Username and Password for the system Default Username aiphone De...

Page 6: ...any priority level After the Door TermID and Relay Action has been set click Apply Settings at the bottom of the screen to save the settings to memory Return to the application screen or reboot adapt...

Page 7: ...vel and target IP address have been set click Apply Settings at the bottom of the screen to save the settings to memory Return to the application screen or reboot adaptor by clicking on the Reboot but...

Page 8: ...er use proper power for the strike mag lock or external signaling device being used PS12 PT PT R2 NO R4 NO R1 NO R3 NO R2 NO R4 NO I1 I2 G G I3 I4 Input 1 Input 2 Input 3 Input 4 Ground Relay 1 Relay...

Reviews: