Aiphone GW-LE8 Instructions Manual Download Page 4

Pg. 4

GW-4P

1

2

3

4

RY-PA

~

~

AC Power

Door Strike

Blk

Yel

GW-LE8

+

-

PS-12C

GW-LE8 WITH GW-4P, USING LEF-3L MASTER STATIONS WITH COMMON AND INDIVIDUAL DOOR STATIONS

NOTES:

1. Remove D+/D-  jumper on all masters.

2. Only components of the entrance panel that include wire connections are shown here.

3. For complete wiring information, please see the standard LEF instructions.

    If additional master stations are to be installed in each office/suite, wire them per the standard instructions.

WIRING DIAGRAM:

LEF-3L #1

1

2

E

+

-

R

K2

L

K1

1

E

-

LE-D

To Indv. Door

Strike &

Power

RY-PA

Blk

Yel

LEF-3L #2

1

E

-

LE-D

To Indv. Door

Strike &

Power

RY-PA

Blk

Yel

LEF-3L #3

1

E

-

LE-D

To Indv. Door

Strike &

Power

RY-PA

Blk

Yel

LEF-3L #4

1

E

-

LE-D

To Indv. Door

Strike &

Power

RY-PA

Blk

Yel

Yel

Blu

Blu

Blu

Blu

Blu

Blu

Blu

Blu

D+

D-

1

2

E

+

-

R

K2

L

K1

1

2

E

+

-

R

K2

L

K1

1

2

E

+

-

R

K2

L

K1

Reviews: