background image

- 14 -

3-5

3-6

Residential Station

[1] Mounting screws (x2)
[2] Mounting bracket
[3] 1-gang box or round back box
[4] Terminal block (GH-1AD, GH-1KD)
1. Mount the mounting bracket on the 1-gang box.
2. Connect the wiring to the terminal block.
3. Mount the station unit to the mounting bracket.

Strip away the jacket of the cable and insert all wires into the 
slots in an orderly fashion. Failure to do so could result in 
pinching that may damage the wiring.

NOTE: To remove the terminal block, slide the terminal block 

and pull it out. (GH-1AD, GH-1KD)

Optional Handset

[1] Chassis
[2] Handset (GH-HS)
[3] Screws (x2)
• Connect the station unit joint connector.

GH-HS can be installed only for the color monitor residential 
station (GH-1KD).

SW1 A

B

IN

OUT

R1 R2 R1 R2 C

0.65 10 9

CE

K KE

Do  not   remove  the   wires  (For end users)

[3]

[3]

[2]

[1]

[4]

[1]

[2]

[3]

OR

60mm (2-3/8")

83.5mm (3-5/16")

1

2

3

SW1 A

B

IN

OUT

R1 R2

R1 R2

C

0.65 10

9

CE K

KE

Do  not   rem

ove  the   w

ires  (For end u

sers)

GH-1MD

GH-1AD
GH-1KD

Summary of Contents for GH Series

Page 1: ... 1 0207 AI C GH SERIES Apartment Intercom System INSTALLATION OPERATION MANUAL ...

Page 2: ...ation but not where it could be jarred or bumped Injury could result 6 Do not alter or change wall mounting of the unit If dropped it can cause injury 7 Do not put high pressure on the video monitor surface If fractured injury could result 8 If LCD is punctured do not allow contact with the liquid crystal inside Inflammation could result If necessary gargle your mouth and clean your eyes or skin w...

Page 3: ...H 1KD GH 1KD GH 1KD a b c d e 1 1 GH 1KD GH HS GH 1MD GH 1AD GH VA GH 1KD GH 1MD GH VBC GH VBC GH VBC SW SW STD EXP SW STD EXP SW STD EXP Max 6 Max 48 Max 25 Trunk Max 48 Max 25 Trunk 1 2 3 4 GH VBC b a e c d 1 2 3 A V P 5 5 6 7 9 10 10 10 10 10 10 10 11 12 13 14 DP 8 150 m 150 m 300 m 150 m PS 2410LC PS 2410LD PS 2410DIN AC AC AC 5 PS24 PS24 PS24 PS24 PS24 PS24 5 5 GH 4Z GH 1KD GH 1KD GH 1KD GH 1...

Page 4: ...control unit GH BC 8 Distribution terminal junction sold separately c Residential station For details see 2 4 Station to station wiring d Residential station For details see 2 4 Homerun wiring Do not mix station to station wiring and homerun wiring on a single trunk line 9 4 way video junction unit GH 4Z 10 Color video residential station GH 1KD 11 Audio residential station GH 1AD 12 Black White v...

Page 5: ...27 7 NAMES SECURITY GUARD STATION Security Guard Station GH MK 27 8 SETTING UP ENTRANCE STATION Adjusting the Camera Angle Entering Names and Addresses 28 Making Adjustments with the Mounting Gauge 29 Setting up the System 30 Programming GH NS 31 Program Mode GH NS 32 9 SETTING UP SECURITY GUARD STATION Programming GH MK 34 Program Mode GH MK 35 10 OPERATIONS ENTRANCE STATION Calling a Residential...

Page 6: ...7 R Q P S Y X W Z 9 0 GH DA A GH DA A GH BC GH VBC b GH VBX GH BCX A 2 1 1 f 2 4 3 DP GH VA GH DA A GH NS GH 10K GH MK Max 8 3 per trunk Max 2 a e 2 B A C 1 3 E D F 5 K J L 4 H G I 6 N M O 8 U T V 7 R Q P S Y X W Z 9 0 2 3 DP 3 DP 3 PS 2410LC PS 2410LD PS 2410DIN AC AC AC Max 125 Max 25 Trunk c d 4 4 4 4 4 4 4 4 4 2 1 2 3 4 b c d b c d b c d b c d PS24 PS24 PS24 PS24 PS24 PS24 PS24 PS24 PS24 PS24 ...

Page 7: ...aximum 1 unit Bus control unit per Sub trunk line Maximum 1 unit Diameter of wires 0 65 mm 22 AWG 0 8 mm 20 AWG 1 0 mm 18 AWG GH BC DP DP GH DA A GH VBC GH VA GH MK DP DP farthest residential station R1 R2 Includes system with GH 4Z GH VBC farthest residential station 1 monitor unit residence Includes system with GH 4Z GH VBC farthest residential station 2 monitor units residence Includes system w...

Page 8: ...dule panel GF 10KP 14 Digital keypad module GH 10K 15 Address module panel GF AP 16 Blank panel GF BP 17 Address module GH AD 18 3 module front frame GF 3F 19 2 module front frame GF 2F 20 Mounting bracket included with GF 3F and GF 2F 21 3 module back box GF 3B 22 2 module back box GF 2B 23 Joint pipe included with GF 3B and GF 2B 24 Mounting gauge included with GF 3B and GF 2B 25 Rain hood GF nH...

Page 9: ...D contains operation manual and setup tool included with GH BC 4 Video Bus control unit GH VBC mounting bracket is not included 5 4 way video junction unit GH 4Z mounting bracket is not included 6 Expanded Bus control unit GH BCX A mounting bracket is included 7 Expanded video Bus control unit GH VBX mounting bracket is included 8 External signaling relay GH RY 9 Mounting screws included with GH R...

Page 10: ...onitor residential station GH 1KD 3 Mounting screws enclosed with GH 1AD and GH 1KD 4 Black and white monitor residential station GH 1MD 5 Mounting screws enclosed with GH 1MD 6 Optional handset GH HS mounting screws are attached back side GH HS can be installed only for the color monitor residential station GH 1KD 1 2 2 B A C 1 3 E D F 5 K J L 4 H G I 6 N M O 8 U T V 7 R Q P S Y X W Z 9 0 3 1 2 3...

Page 11: ...would like to connect 7 modules or more please contact Aiphone 3 Mount each module panel to the front frame Mount the panels from behind the front frame Insert the notch into the slots on both sides and slide it downward 4 Mount each module to the mounting bracket Set the modules in the mounting bracket until they click in place 5 Options a Rain hood GF H b Surface mount box GF 202B c Hooded surfa...

Page 12: ...er the terminal cover for protection 3 Connect the connectors between the modules with cables 4 Run the connection cable through the joint pipe which you should have made open in advance and connect CN1 of GH SW to the next row 5 Put back the terminal cover 1 2 3 CN3 CN1 GH VA GH DA A CN1 CN3 CN100 CN2 CN1 CN2 GH DA A GH AD GH NS GH 10K GF C GH DA A GH AD GF BP GF 3B GF 3B GH 10K GH VA GH NS GF C ...

Page 13: ...GH BC and GH VBC directly to the wall surface 3 Mount GH 4Z to the Din rail To remove GH 4Z pull the lock release lever down 4 Mount GH 4Z directly to the wall surface 5 Mount GH BCX A and GH VBX to the Din rail To remove GH BCX A and GH VBX pull the lock release lever down 1 GH BCX A and GH VBX cannot be mounted directly to the wall surface 2 The length of the connecting cable between the GH BCX ...

Page 14: ... Failure to do so could result in pinching that may damage the wiring NOTE To remove the terminal block slide the terminal block and pull it out GH 1AD GH 1KD Optional Handset 1 Chassis 2 Handset GH HS 3 Screws x2 Connect the station unit joint connector GH HS can be installed only for the color monitor residential station GH 1KD SW1 A B IN OUT R1 R2 R1 R2 C 0 6510 9 CE K KE Do not remove the wire...

Page 15: ...n Wall mounting 1 1 gang box or round back box 2 Mounting bracket 3 Wiring slot 4 Terminal block 1 Mount the mounting bracket on the 1 gang box 2 Connect the wiring to the terminal block 3 Mount the station unit to the mounting bracket Strip away the jacket of the cable and insert all wires into the slots in an orderly fashion Failure to do so could result in pinching that may damage the wiring NO...

Page 16: ...ng with GH 4Z Station to station wiring Light control Timer Light AC GH RY Standard system Doorbell On the same trunk line do not have two wiring methods mixed Station to station wiring and homerun wiring with GH 4Z GH 1MD unlike GH 1KD is only available to connect on a trunk line with GH 4Z used Max 4 apartment stations can be linked per Residence including max 2 monitor stations Capacity 5 Entra...

Page 17: ...line 3 6 1Px2 1Px2 B1 B2 B1 B2 A1 A2 B1 B2 B1 B2 B1 B2 B1 B2 OUT1 IN1 A1 A2 IN2 A1 A2 IN3 A1 A2 IN4 A1 A2 IN5 OUT2 OUT3 OUT4 OUT5 OUT6 R1 R2 AC GH BC GH VBC AC AC Video Entrance station 2 5 GH 1KD OUT IN OUT IN C CE B1 B2 B1 B2 R1 R2 R1 R2 B A R1R2 ELB ELC ELM RY RY CN2 CN1 GH DA A GH RY GH NS GH 10K GH VA GH MK 2 GH MK 1 CN3 CN100 C CE R1 R2 R1 R2 C CE R1 R2 R1 R2 Distribution point SW1 SW1 ON ON...

Page 18: ... 2410LC PS 2410LD PS 2410DIN AC AC AC d c 1 10 12 4 5 6 8 9 13 DP PT GH RY AC 1 2 SW1 ON 1 2 3 4 ON 1 2 3 4 7 R1 4 5 6 2 3 1 R2 GH BC R1R2 GH VBC 11 SW2 EXP STD 1P NP 1P NP 1P NP GH DA A 4 5 1P NP 1P NP 1P NP 1P NP 1P NP 1 P N P 1 P N P 1 P N P 1 P N P SW2 EXP STD 1 P N P 1 P N P 1 P N P 1 P N P 1 P N P A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2...

Page 19: ...s make sure to set the GH DA A ID numbers SW2 4 External signaling relay GH RY For details see 4 5 5 Door release relay contact Less than AC DC 24 V 4 A resistance load PT AC Transformer 6 Security guard station GH MK 7 Setting switch GH MK SW1 1 Password reset switch Set the password reset switch to ON for 2 seconds or more during standby will reset the password set to 1111 at time of shipment SW...

Page 20: ...B1 R2 R1 B2 B1 R2 R1 B2 B1 GH 4Z R2 R1 B2 B1 R2 R1 B2 B1 R2 R1 B2 B1 R2 R1 B2 B1 R2 R1 B2 B1 R2 R1 B2 B1 R2 R1 B2 B1 R2 R1 B2 B1 R2 R1 B2 B1 R2 R1 B2 B1 R2 R1 B2 B1 R2 R1 B2 B1 SW1 B A SW1 A B SW1 A B IN OUT IN OUT R1R2R1R2 B1B2B1B2 C CE K KE IN OUT IN OUT R1R2R1R2 B1B2B1B2 C CE K KE IN OUT IN OUT R1R2R1R2 B1B2B1B2 C CE K KE IN OUT IN OUT R1R2R1R2 B1B2B1B2 C CE K KE GH 1AD GH 1MD IN OUT R1R2 R1R2 ...

Page 21: ... GH 1KD GH 1AD GH 1MD For GH 1KD set the setting switch SW1 to A 3 Short lead To use the emergency alarm switch see 11 7 for details disconnect the short lead and connect the switch 4 External signaling relay GH RY For details see 4 5 The separate option connecter is required 5 Doorbell Do not mix homerun wiring with station to station wiring on the same trunk line NP Non polarized ...

Page 22: ...K 1 GH 1KD Doorbell GH 1KD Doorbell 1Px2 1Px2 R1 R2 Trunk line 2 6 SUB1B SUB2A SUB2B Entrance 1 8 Entrance 2 8 1Px2 1Px2 1Px2 1Px3 PS24 PS24 PS24 PS24 PS24 PS24 PS24 PS24 PS24 PS24 GH BCX A GH VBX R1 R2 R1 R2 Capacity 16 Entrance stations 4 Security guard stations 500 Residential stations Trunk line 1 2 B A C 1 3 E D F 5 K J L 4 H G I 6 N M O 8 U T V 7 R Q P S Y X W Z 9 0 2 B A C 1 3 E D F 5 K J L...

Page 23: ...OMMON1 COMMON2 GH BCX A GH 1KD OUT IN OUT IN C CE B A GH 1KD OUT IN OUT IN C CE B1 B2 R1 R2 B A Door bell Door bell CN1 Entrance 1 8 Entrance 2 8 SUB1B COMMON1 COMMON2 SUB1A SUB2A SUB2B R1 R2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 1Px2 1Px2 1Px2 1Px2 1Px2 B1 B2 R1R2 R1R2 R1R2 R1R2 R1R2 B1 B2 B1 B2 R1 R2 R1 R2 R1 R2 R1 R2 B1 B2 B1 B2 B1 B2 R1 R2 R1R2 B1 B2 B1 B2 Trunk line 2 6 PS24 PS24 PS24 PS24 PS24...

Page 24: ...A SUB1B SUB2A SUB2B 3 f 4 PS24 Power OFF ON R1 R2 PC GH DA A 4 6 GH NS 1 3 GH MK 1 2 GH MK 1 2 GH VA 1 8 1 GH VA 1 a 1 GH MK 1 e 2 B A C 1 3 E D F 5 K J L 4 H G I 6 N M O 8 U T V 7 R Q P S Y X W Z 9 0 2 1 2 3 4 6 7 8 5 SW2 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 1 2 SW1 ON 1 2 3 4 ON 1 2 3 4 GH MK 2 GH DA A 2 3 GH NS 2 3 GH VA 2 8 A1 A2 GH DA A 1 R1 ...

Page 25: ... For connecting the lift control adaptor GHW LC refer to the GHW LC Installation Operation Manual 5 Bus control unit GH BC 6 Distribution terminal junction not included 7 Power supply PS 2410LC PS 2410LD PS 2410DIN NP Non polarized NOTE For communication between Entrance station and Residential station one each communication path is available to COMMON1 SUB1 and COMMON2 SUB2 In case of crossover c...

Page 26: ...ule GH SW 11 Directory card 12 Call button Residential station GH 1AD GH 1KD 1 Speaker 2 Microphone 3 Door release button Monitor button GH 1KD only 4 Talk button 5 Light button Security guard station call button 6 Service button option 7 Talk LED 8 Call tone off LED 9 Receive volume control 10 Call tone volume control 11 Video monitor 3 5 inch color LCD 12 Monitor brightness control 5 NAMES ENTRA...

Page 27: ...set 2 Display 3 Cancel button or set and return 4 Back search button or move cursor to the left 5 Forward search button or move cursor to the right 6 Call button or set and move forward 7 10 key 0 9 8 Service button option 9 Light button 10 Door release button 11 Off hook LED 12 Speaker 13 Call tone volume control 14 RS 232 connection 3 5 mm port 7 NAMES SECURITY GUARD STATION GH MK GH 1MD 1 8 2 3...

Page 28: ...s been adjusted to the left 2 When camera has been adjusted to the right 8 2 Entering Names and Addresses Remove the resident name address plate or paper by pressing the left or right end Peel off the plastic film Use a permanent pen to write the resident name and address on the transparent plate and mount the plate on the module 8 SETTING UP ENTRANCE STATION 1 2 3 GH VA 113cm 24cm 24cm 50cm 113cm...

Page 29: ...auge 1 Mounting gauge To mount multiple rows of panels apply the mounting gauge to the mounting bracket While using the mounting gauge to make adjustments tighten the screws There is a mounting gauge for the built in back box of GF 2B and GF 3B 1 1 ...

Page 30: ...l button of GH SW or GH NS until you hear a continuous beep For GH NS display the room you want to correct and reprogram all the residential stations in the single apartment following steps 4 and following 8 Ending programming Push the GH DA A program switch The In Use LED will go off Replace the cap 9 Checking the programming Pressing the program switch for 5 seconds or more will light up the In ...

Page 31: ...tem to program mode For details see above Before you begin programming we recommend that you register a new exclusive ID code for yourself so that the system is not accessed by others For details see 8 6 If you have forgotten your ID code set the switch 1 to ON for approximately 2 seconds The ID code will be reset to the default setting of 1111 NOTE To display only resident name without room numbe...

Page 32: ...e S M Enter ROOM Menu 5 YOUR OPERATION DISPLAY 101 SMITH 0 1 1 DECIDE BACK DECIDE NEXT DECIDE NEXT DECIDE NEXT Move cursor TO RIGHT TO LEFT 7 R Q P S 7 R Q P S 7 R Q P S 7 R Q P S 6 N M O Menu 6 2 digit 15 99 PROGRAM TIMER 60 SET TIMER OPERATION TIMER 15 2 digit 30 99 YOUR OPERATION DISPLAY CALL DURATION 45 2 digit 30 99 9 Y X W Z DECIDE BACK DECIDE NEXT DECIDE NEXT 3 E D F 0 0 0 6 N M O Enter WEL...

Page 33: ...Residential Programming mode the operation panel is not operated for a certain period of time it automatically cancels the programming mode Programmable from 30 to 99 seconds Call Timer Call from Entrance panel expires in a certain period of time Programmable from 30 to 99 seconds 6 Menu 6 Change greeting Enter greeting message up to 160 characters 7 Menu 7 Transfer link information With Expanded ...

Page 34: ... N M O 8 U T V 7 R Q P S Y X W Z 9 0 2 3 4 5 6 AIPHONE INITIAL ID CODE INITIAL ID CODE DISPLAY YOUR OPERATION RE ENTER ID CODE YOUR OPERATION SELECT LANGUAGE DISPLAY MENU Standby FORWARD Scroll BACKWARD Go to Menu 1 7 1 2 3 4 5 6 7 8 SELECT LANGUAGE CHANGE ID CODE RESIDENT INFO SET TIMER PROGRAMMING TRANSFER DATA VERIFY PROGRAM QUIT 1 1 1 1 ID CODE 4 digit 1 1 1 1 DECIDE BACK DECIDE NEXT Beep b a ...

Page 35: ...ation 3 Press the talk button on the first residential station The corresponding communication channel will be established For other GH MK lift the handset 4 Use the search button to display the assigned name and then press the call button 5 If an electronic beep is emitted once the residential station has been set up successfully If an electronic sound is emitted twice it is for the second reside...

Page 36: ... DECIDE NEXT Move cursor TO RIGHT TO LEFT 7 R Q P S 7 R Q P S 7 R Q P S 7 R Q P S 6 N M O Menu 5 2 digit 15 99 PROGRAM TIMER 60 SET TIMER OPERATION TIMER 15 2 digit 30 99 YOUR OPERATION DISPLAY 9 Y X W Z DECIDE BACK DECIDE NEXT DECIDE NEXT 3 E D F 0 0 CALL DURATION 45 2 digit 30 99 9 Y X W Z 0 6 7 9 2 1 or 2 digit 1 16 ENTER UNIT ID SECURITY GUARD TRANSFER DATA ENTER UNIT ID MAIN ENTRANCE YOUR OPE...

Page 37: ...g mode Programmable from 30 to 99 seconds Call Time Call from Entrance panel expires in a certain period of time Programmable from 30 to 99 seconds 5 Menu 5 Programming For the programming procedures see 9 1 6 Menu 6 Transfer link information With Expanded System enter unit ID for transferring Entrance stations and Security guard stations as below Entrance station Connected to same common line pro...

Page 38: ... number c Making a call by entering letters and selecting the corresponding name NOTE If you push a call button that has been programmed to activate a light the entrance light will turn on GH SW only 1 2 b c a Press button intermittently or hold down for 2 sec to show in succession CALLING SMITH DISPLAY YOUR OPERATION FORWARD Scroll BACKWARD CALL WELCOME 101 SMITH SMITH example CALL DISPLAY YOUR O...

Page 39: ... the talk button for at least one second while talking handsfree a beep will be emitted and you can communicate by press to talk communication In press to talk communication you press the talk button to talk and release it to listen 3 When you are done talking press and hold down the talk button The communication will be ended automatically after approximately 1 minute when handsfree communication...

Page 40: ...ching the automatic entry function on and off Press the light button while holding down the talk button of the residential station for which this function is set to switch the function on and off When the function is on the Call tone off LED on GH 1KD GH 1AD and TALK LED on GH 1MD will flash at 2 5 second intervals in standby 11 5 Calling the Security Guard Station Press the light security guard s...

Page 41: ... will be unable to receive normal calls or doorbell calls while the emergency alarm is sounding It is only possible to respond call from the security guard station 4 During the emergency alarm the entrance station cannot make calls to the residential station that set off the alarm or to the security guard station Monitoring Entrance Stations With a monitor station you can monitor entrance stations...

Page 42: ...s pressed 4 Press the light button once while in communication 5 The outside light of the entrance will turn on for the preset duration of time 4 5 based on timer module used Replying to a Call from a Residential Station 1 When a call is received from a residential station a call tone will sound for approximately 10 seconds at the security guard station and the room number and resident name will b...

Page 43: ...g b Making a call by entering the room number c Making a call by entering letters and selecting the corresponding name NOTES 1 Pressing the search button for approximately 2 seconds will automatically display the resident names every 0 4 seconds 2 If both room number 111 and 1111 exist the resident name for room 111 will be displayed when 1 1 1 is entered and the resident name for room 1111 will b...

Page 44: ... on a security guard station and that station is in communication another security guard station cannot interrupt An in use tone will be heard from the handset of the security guard station 2 The security guard station can respond to the emergency alarm from the residential station or can make normal calls to other residential stations However the name scrolling function will not work on the secur...

Page 45: ...alled residential station press CALL button 4 After communication with residential station hang up handset to establish the communication between caller entrance station and called residential station Calling from the Doorbell Button 1 The doorbell button is pushed A call tone sounds as long as the button is held down 2 A different call tone sounds there is no communication available 12 9 Missed c...

Page 46: ...H BCX A 0 45 A Call tone There are three different types of call tones a call tone for the entrance station a call tone for the security guard station and a call tone for the doorbell button Communication path Single path non open Communication Voice actuated communication or press to talk communication Door release Connecting terminals Between ELM ELC N O and ELB ELC N C Specifications less than ...

Page 47: ...n experienced radio TV technician for help Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of two years after delivery to the ultimate user and will repair free of charge or replace at no charge should it become defective upon which examination shall disclose to be defective and under warranty Aiphone reserves unto itself ...

Reviews: