6
4.2 Functions & Adjustments of Nozzles
There are two nozzles on the cleaner, one of them opens when the other
closes. Water flows out through the open nozzle to thrust the cleaner to
move forward. Adjust the nozzle by turning it to control the moving route.
a. Settings of nozzle angle and moving route
Sketch: the nozzles of the cleaner are marked with angles (0°-40°). The
cleaner
moves in an approximately straight line when the nozzle angle is
0°. The cleaner moves in a more curved line at a larger angle from 0°-40°.
b. Recommended three cycles and nozzle settings
Setting One: default setting: 0°--20°, for most of the pools.
Nozzle Angle
Moving Route
Nozzle Angle
Moving Route
Setting Two: 0°--40°, when the cleaner does not have full coverage of
the pool.