1
12
Introduction
AIMS Power inverter series are the most advanced line of mobile
AC
power systems available.
This model is used in a wide range of applications including
remote homes,
RV's
, sail boats and power boats. It will operate
most televisions and
VTR's
, personal computers, small appliances
and tools such as drills, sanders, grinders, mixers and blenders.
To get the most out of the power inverter, it must be installed
and used properly. please read the instructions in this manual
before installing and using this model.
Name and main function
1.
Front view
a.ON/OFF switch:
Leave in the OFF position during installation.
b.Over Temperature indicator:
Lights when inverter protects itself against overheating.Inverter
shuts down while indicator is on. Inverter will restart automatically
and indicator will trun off when the inverter cools.
c.Overload indicator:
Lights when inverter shuts down because of overload. Indicator will
turn off and inverter will restart when overload is removed.
b.OVER TEMPERATURE INDICATOR
e.AC OUTLET
a.ON/OFF SWITCH
d.BAR GRAPH METERS
c.OVER LOAD INDICATOR
ON
OFF
Over Temp
Over Load
BATTERY
15
14
13
12
11
10
600
480
360
240
120
Note:1.Only connect to "AC Terminal block" when the
Main Power ON/OFF switch is OFF.
2.lnverter's full power is avail able through
the AC Terminal Block.
AC Terminal Block
Live
Neutral
Ear th
Remote
MAX. 1500W
per outlet
g.AC TERMINAL BLOCK
f.REMOTE PORT
No output voltage, High input voltage Make sure that
voltage indicator inverter
in upper red zone. is connected to
36V battery.
Check regulation of
charging system.
________________________________________________________
Low battery alarm Poor DC wirng, poor Use proper cable
on all the time, battery condition. and make Solid
voltage indicator connections. Use
below 33V new battery
________________________________________________________
No output voltage, Thermal shutdown Allow inverter to
Over Heat indicator cool off.Reduce
on,load in excess load if continuous
________________________________________________________
No output voltage, Thermal shutdown Improve ventilation,
Over Heat indicator make sure ventilation
on, load less than: openings in inverter
5000W:167A(36V) are not obstructed,
reduce ambient
temperature.
________________________________________________________
No output voltage, Sort circuit or Check AC wiring
Over Load indicator Wiring error: For short circuit or
on. improper polarity
(active and neutral
reversed)
Very high power load Romove load
________________________________________________________
Maintenance
Very little maintenance is required to keep your inverter operating
properly. You should clean the exterior of the unit periodically
with a damp cloth to prevent accumulation of dust and dirt. At
the same time, tighten the screws on the DC input terminals.
5000W:167A(36V) operation required.