background image

1

12

Introduction

AIMS Power inverter series are the most advanced line of mobile 

AC

 power systems available.

This  model  is  used  in  a  wide  range  of applications including
remote homes,  

RV's

,  sail boats and power boats. It will operate

most televisions and 

VTR's

, personal computers, small appliances

and tools such as drills, sanders, grinders, mixers and blenders.

To get the most out of the power inverter, it must be installed
and used properly. please read the instructions in this manual
before installing and using this model.

Name and  main function

1.

 Front view

a.ON/OFF switch:
   Leave in the OFF position during installation.

b.Over Temperature indicator:
   Lights when inverter protects itself against overheating.Inverter

  

   shuts down while indicator is on. Inverter will restart automatically 
   and indicator will trun off when the inverter cools.

c.Overload indicator:
   Lights when inverter shuts down because of overload. Indicator will
   turn off and inverter will restart when overload is removed.

b.OVER TEMPERATURE INDICATOR

e.AC  OUTLET

a.ON/OFF SWITCH 

d.BAR GRAPH METERS

c.OVER LOAD INDICATOR

ON

OFF

Over Temp

Over Load

BATTERY

15

14

13

12

11

10

600
480
360
240
120

Note:1.Only connect to "AC Terminal block" when the

             Main Power ON/OFF switch is OFF.

          2.lnverter's full power is avail able through

             the AC Terminal Block.

AC Terminal Block

Live

Neutral

Ear th

Remote

MAX. 1500W

per outlet

g.AC TERMINAL BLOCK

f.REMOTE PORT

No output voltage,          High input voltage         Make sure that
voltage indicator                                                      inverter                           
in upper red zone.                                                     is connected to 
                                                                                    36V battery.
                                                                                    Check regulation of
                                                                                    charging system.
________________________________________________________
Low battery alarm          Poor DC wirng, poor      Use proper cable
on all the time,                battery condition.           and make Solid
voltage indicator                                                      connections.  Use
below 33V                                                                 new battery

________________________________________________________
No output voltage,         Thermal shutdown          Allow inverter to
Over Heat indicator                                                  cool off.Reduce
on,load in excess                                                       load if continuous

________________________________________________________
No output voltage,           Thermal shutdown        Improve ventilation,
Over Heat indicator                                                  make sure ventilation
on, load less than:                                                     openings in inverter
5000W:167A(36V)                                                  are not obstructed,
                                                                                    reduce ambient
                                                                                    temperature.
________________________________________________________
No output voltage,                 Sort circuit or          Check AC wiring
Over Load indicator               Wiring error:           For short circuit or 
on.                                                                               improper polarity
                                                                                    (active and neutral
                                                                                    reversed)
                                              Very high power load Romove load
________________________________________________________

Maintenance

Very little maintenance is required to keep your inverter operating
properly. You should clean the exterior of the unit periodically
with a damp cloth to prevent accumulation of dust and dirt. At
the same time, tighten the screws on the DC input terminals.

5000W:167A(36V)                                                  operation required.

Summary of Contents for PWRINV500036W

Page 1: ...t and duty charges incurred outside the contiguous 48 United States will be prepaid by customer Except as provided above AIMS makes no warranty of any kind express or implied including without limitation the implied warranties of merchantability and fitness for a particular purpose In no event shall AIMS be liable for indirect special or consequential damages This warranty only applies to AIMS Pow...

Page 2: ...emperature protection Efficiency Weight Input Voltage Range Low Voltage Alarm Output Surge Capacity Output Wave Form Switch OFF Switch ON No Load Current Draw Dimensions L x W x H PWRINV500036W 5000W 30 45V 570x210x180mm or 22 44 x8 26 x7 08 0 4 ADC 0 2 mADC Modified Sine Wave phase corrected 90 5 c 55 c 11KGS or 242 LBS 10000W DC 31 5V 1 5V DC 30V 1 5V ...

Page 3: ...Terminal Block Live Neutral Earth Remote MAX 1500W per outlet g AC TERMINAL BLOCK f REMOTE PORT No output voltage High input voltage Make sure that voltage indicator inverter in upper red zone is connected to 36V battery Check regulation of charging system ________________________________________________________ Low battery alarm Poor DC wirng poor Use proper cable on all the time battery conditio...

Page 4: ...ndow c Chassis grounding b Battery terminals X 11 Keep the cables between the battery and the power inverter as short as possible and twist them togerter with about 2 to 3 twists per foot This minimizes radiated interference from the cables 2 Troubleshooting guide ______________________________________________________ Problem and Symptoms Possible Cause Solution ___________________________________...

Page 5: ...capacitors in the power inverter Do not make this connection in the presence of flammable fumes as explosion or fire may result 3 10 The power inverter will also shut down if the input voltage exceeds 50V This protects the inverter against excessive input voltage The voltage indicator will be in the upper red zone Although the power inverter incorporates protection against overvoltage it may still...

Page 6: ...n any compartment capable of storing flammable liquids such as gasoline 4 9 the power delivered to the food not the power actually consumed by the microwave oven The microwave oven will consume 40 to 100 more than its advertised cooking power Check the rating sticker on the back of the oven to determine its actual power draw The 5000W inverter will operate small microwave ovens 0 2 to 0 3 cubic fo...

Page 7: ...tied to ground at the AC breaker panel 5 Ideally the voltage should remain in the green area of the bar graph If the voltage goes into the red area at the top or bottom of the graph the inverter may shut down 3 Battery current indicator The battery current bar graph indicates the current drawn from the battery by the power inverter It will not indicate current by other loads also connected to the ...

Page 8: ...verter When the switch is in the OFF position the power inverter draws no current from battery When the switch is in the ON position but with no load the power inverter draws less than 1 Amp 2 Battery voltage indicator The battery voltage bar graph indicates the voltage at the input terminals of the power inverter At low input current this voltage is very close to the battery voltage At high input...