background image

3.

4.

3) Remote control box (not included)

Remote control interface

4.  ASSEMBLE

1. Location

      First  ensure  that  there  is  enough  space  to  install  the  inverter,  while  the  installation   

location must meet the following requirements:

(1) Dryness: Avoid dripping water or other liquids on the inverter.

(2)  Coolness:  The  operating  temperature  for  the  product  is  32-104°F(0-40°C),  the 

preferable  temperature  is  50-77°F(10-25°C),  the  lower  temperature  is  better  within 

this range.

(3) Ventilation: There should be a certain distance between inverter and other objects, to 

avoid blocking the product's vents. Allow 2 inches (5cm)from openings.

(4) Cleanness: Do not install the product around dust, wood chips or other particles. When 

the cooling fan turns on, the particles will be sucked into the inverter , thus increasing 

internal temperature..

(5)  When  connecting  inverters  and  batteries,  it  will  produce  arcs  or  sparks,  so  there 

should not be flammable objects around, such as gasoline, alcohol, etc.

2.  Mounting instructions

     Mount on a solid platform because of the  heavy weight, such as floor, table or stable 

support.  In  order  to  avoid  sliding  off,  the  platform  should  bear  the  weight  of  the  product, 

and it is better to attach the product with four screws. 

3. Mounting the remote control box (Optional equipment)

  

1

3  / "

16

5

2  / "

16

1

2  / "

16

5

1  / "

16

1) the remote is designed to be mounted on a dash or other surface where a hole  should 

    be cut so that it sits flush.  This is not a requirement however just a  recommendation.   

2) The remote cable should be plugged into inverter and the remote before mounted. 

Note: 

Optional remote is not needed for inverter operation.  The main power switch will 

           work  the power on / off.

5. Battery

1). Voltage and current of the battery

    The battery is designed to supply the unit with DC input voltage and the rated 

voltage should be in accordance with the rated input voltage of the inverter. Any 

voltage exceeding the range of the input voltage of the inverter will cause over 

voltage or under voltage protection.

      Also,  the  battery  must  supply  sufficient  current.  A  small  capacity  battery 

cannot  drive  a  large  power  electrical  appliance.  In  this  case,  the  battery  will 

cause an under voltage protection because of the over-discharge of the battery. 

The  simple  calculation  method  of  battery  current  is:  load  power  divided  by 

battery voltage. Due to the consumption of the inverter itself, the actual current 

will  be  about  10%  larger.  For  example,  the  voltage  of  a  lead  acid  battery  is 

12VDC, and load power is 1000W, therefore, the actual current of the battery is 

about 1000W÷12V×110%≈91.6Adc.

  

69 mm

59 mm

44 mm

34 mm

13

11  / "

16

11

8  / "

16

(320mm)

(216mm)

Summary of Contents for AIMS Power PE300012230S

Page 1: ...WARNING Please read this manual in its entirety before using or connecting this inverter It includes important instructions and safety tips Model number PE300012230S PE300024230S ...

Page 2: ...2x40A 12x20A 0 40 540x236x95mm 6 8kg 7 3kg boxed Temperatur 40 optional PE300012230S PE300024230S 12VDC 24VDC Model Power supply Voltage Output voltage Output frequency Output wave form Continuous power output Peak power output Under voltage safeguard Over voltage safeguard USB outlet Fuse Operating temperature Dimension LxWxH Weight Cooling fan Remote 230Vac 50Hz Pure sine wave 3000W 6000W 10VDC ...

Page 3: ...four screws 3 Mounting the remote control box Optional equipment 1 3 16 5 2 16 1 2 16 5 1 16 1 the remote is designed to be mounted on a dash or other surface where a hole should be cut so that it sits flush This is not a requirement however just a recommendation 2 The remote cable should be plugged into inverter and the remote before mounted Note Optional remote is not needed for inverter operati...

Page 4: ...In high current the input DC wire may produce a voltage drop therefore the operating voltage should be subject to the value on the terminals If the voltage drop is too large you can increase the cross sectional area or reduce the length of the lead 3 Connect cathode wire of the battery to the cathode terminal black on the rear panel of the inverter and then connect the anode wire of the battery to...

Page 5: ...6 The cooling fans inside the inverter do not work until the case temperature rises up to about 104 F or 40 C 7 Switch off inverter or remote to turn off At that time the indicator lights for both inverter and remote are off The inverter does not consume current from the battery when it is switched off How to use USB power supply This model supplies a USB output and provides stable voltage at 5V D...

Page 6: ...irst then open the inverter Use the internal soft start circuit of the inverter to buffer the start 11 Troubleshooting tips AIMS Power Warranty Instructions This product is designed using the most modern digital technology and under very strict quality control and testing guide lines If however you feel this product is not performing as it should please contact us techsupport aimscorp net or 001 7...