![AIMS Power Global LF Series User Manual Download Page 25](http://html.mh-extra.com/html/aims-power/global-lf-series/global-lf-series_user-manual_2871983025.webp)
23
Reducing RF interference
To reduce the effect of radiated interference, twist the DC cables. To further reduce RF interference, shield
the cables with sheathing /copper foil / braiding.
Taping battery cables together to reduce inductance
Do not keep the battery cables far apart. In case it is not convenient to twist the cables, keep them taped
together to reduce their inductance. Reduced inductance of the battery cables helps to reduce induced
voltages. This reduces ripple in the battery cables and improves performance
and efficiency.
3-4
. AC Wi
ring
The AC terminal is rated for wires of 8 AWG to 20 AWG, we recommend using 10 to 8 AWG wire to connect to
the ac terminal block. When in AC mode the AC input power will supply both the loads and AC charger, a
thicker wire gauge for AC input is required. Please consult a qualified electrician about the specific wire gauge
required in terms of wire material and inverter power. There are several ways of connecting the terminal block
depending on the model. All the wirings are CE compliant. call our tech support if you are not sure about how to
wire any part of your inverter.
STOP:
DON'T WIRE UNTIL YOU CONFIRM THE MODEL NUMBER OF YOUR INVERTER. NOTE
WHETHER YOU HAVE A 120 SINGLE PHASE OR 120/240V SPLIT PHASE.
Summary of Contents for Global LF Series
Page 2: ......
Page 17: ...15 2 5 8 LED Indicator Lights Status ...
Page 29: ...27 3 6 Install Flange 1000W 1500W Models 2000W 3000W Models 4000W 6000W Models ...
Page 30: ...28 DC Side View ...
Page 36: ...34 ...
Page 38: ...36 Appendix 2 Installation Diagram DC shunt is not required ...
Page 39: ......
Page 40: ...614 01206 09 ...