AIMS Power GEN3850W120VD Manual Download Page 15

 

15 

  The economy control switch must be turned to 

OFF

 

when using electric devices that require a large 
starting current, such as a compressor or a 
submergible pump. 

FIG 24

 

 

2

OVERLOAD INDICATOR LIGHT 

FIG.25

 

 

The overload indicator light will blink when the rated load 

is exceeded. Reduce the loads to its normal range and 

the overload indicator light will turns  off. When the 

maximum load is reached, output pilot light will turn off, 

the overload indicator light will turn on and cut power to 

the receptacles. To reset the output: 

(a)  Turn off any connected electric devices 

(b)  Reduce the total wattage of connected electric. 

(c)  Check for blockages in the cooling air inlet, muffler 

air exhaust pipe opening and the control unit. 

(d)      After inspection, press the reset button to restore 
the power: 

FIG.26

 

 

CAUTION 

  The generator AC output automatically resets when the engine restarted. 

  The overload indicator light may come on for a few seconds at first when using electric 

devices that require a large starting current, such as a compressor or a submergible pump. 
This is not a malfunction. 

 
 
 
 
 
 
 
 
 
 
 

FIG.25 

 

FIG.24 

 

FIG.26 

 
 

Summary of Contents for GEN3850W120VD

Page 1: ...1 IMPORTANT READ THE USER S MANUAL BEFORE OPERATION INVERTER GENERATOR 3850 WATT GEN3850W120VD...

Page 2: ...of yourself and others around you The inverter generator ships without gas or oil Do not operate until all checks have been made according to this manual YOU MUST ADD OIL AND GAS TO OPERATE CHECK OIL...

Page 3: ...l spills on your skin or clothing immediately wash with soap and water and change your clothes When operating or transporting the generator be sure it is kept upright If it tilts fuel may leak from th...

Page 4: ...g handle Put the generator on flat ground allowing generator to vent heat freely ELECTRIC SHOCK PREVENTION Never operate the engine in rain or snow Never touch the generator with wet hands or electric...

Page 5: ...5 SAFETY SYMBOLS Caution The user should be aware of a general hazard Dangerous Voltage Flammable Hot Surface Do not touch...

Page 6: ...er30A 8 ACprotector20A 9 Paralleloutlets 10 Ground earth terminal 11 120VOUTPUT 12 RVsocket 13 USBoutput 14 DC12Voutput 15 Choke 16 Fuelselectorswitch 17 Recoilstarter 18 ConnectionforLP 19 Fuelmeter...

Page 7: ...tem START Starting circuit is switched on The starter motor starts RUN Ignition circuit is switched on The engine can start STOP Ignition circuit is switched off The engine will shut off ECONOMY CONTR...

Page 8: ...isplay meter shows the voltage electric current power and run time by pressing the multifunction button Normal Short circuit Over current Maintenance High Volt of AC output with E1AC indicated High Vo...

Page 9: ...y switch to ON the circuit of the start motor and carburetor solenoid is connected OFF Turn the battery switch to OFF the circuit of the start motor and carburetor solenoid is disconnected CAUTION Alw...

Page 10: ...fill above the top of the fuel filter or it may overflow when the fuel heats up and expands Wipe off spilled fuel thoroughly before starting engine Keep away from open flames CHECK ENGINE OIL Make sur...

Page 11: ...ECT BATTERY for electric starting system Loosen the screw and remove the battery holder FIG 15 Bolt red wire to the positive terminal and the black wire to the negative terminal of the battery Do not...

Page 12: ...or will light FIG 16 3 Turn the engine switch to the RUN position FIG 17 4 Pull the choke to the START position Not necessary if the engine is already warm FIG 18 5 Pull the starter cord slowly until...

Page 13: ...ld the engine switch to the START position Release as the engine begins to start If the engine fails to start within five seconds release the switch and wait at least ten seconds before attempting to...

Page 14: ...ould turn on FIG 16 page 12 5 Pull the choke out to CHOKE position FIG 18 page 12 7 Turn the engine switch to the RUN position FIG 22 page 13 8 Press and hold the engine switch to the START position R...

Page 15: ...tor light will turn on and cut power to the receptacles To reset the output a Turn off any connected electric devices b Reduce the total wattage of connected electric c Check for blockages in the cool...

Page 16: ...he LPG tank valve Press the engine switch to OFF turn the battery switch to OFF disconnect the quick connect from the generator shift the fuel selector switch to GASOLINE FIG 28 4 Make sure battery sw...

Page 17: ...ld Fuel Line Check fuel hose for cracks or damage Replace if necessary Exhaust System Check for leakage Retighten or replace gasket if necessary Check muffler screen Clean replace if necessary Carbure...

Page 18: ...not tilt the generator when adding engine oil This could result in overfilling and damage to the engine AIR FILTER Maintaining the air filter is very important If dirt penetrates through the filter be...

Page 19: ...e color Tan Color Standard Spark Plug F7RTC TORCH Spark Plug Gap 0 6 0 7 mm 0 024 0 028 in FUEL TANK FILTER 1 Remove the fuel tank cap and filter FIG 34 2 Clean the filter with solvent If damaged repl...

Page 20: ...d carburetor clean carburetor 2 LPG system There is no gas in the combustion chamber The gas tank is empty change to a full tank The carburetor is clogged clean the carburetor 3 Engine oil system Insu...

Page 21: ...Use the recoil starter to turn the engine over several times with ignition off 3 Pull the recoil starter until you feel compression 4 Stop pulling 5 Clean exterior of the generator and apply a rust in...

Page 22: ...OHV Gasoline Engine Bore Stroke mm mm 70 58 Displacement 223 cc Max Output 4 5KW 3800rpm Fuel Unleaded Automobile Gasoline LPG Fuel tank Capacity 4 5 GAL Rated Continuous Operation 7 5 hours 100 Load...

Page 23: ...GROUND TERMINAL IGNITION CONTROLLER STEPPER MOTOR ASSY GRAY BLACK WHITE PI Gr PINK BL W ORANGE YELLOW O Y BL Bu BLACK BLUE BROWN RED Br R W WHITE G GREEN P PURPLE W BL P W IGNITION COIL BL R Y G R BL...

Reviews: