background image

UEC-4800EPL Upgrade Kit

INSTRUCTION MANUAL

Summary of Contents for UEC-4800EPL

Page 1: ...UEC 4800EPL Upgrade Kit INSTRUCTION MANUAL ...

Page 2: ......

Page 3: ...e UEC 4800 2 Remove the two screws that hold the front panel to the UEC 4800 3 Remove the cover of the UEC 4800 4 Push the front panel free from its connector and place to the side 5 Remove the two screws on both sides that hold the board in place 6 Move the board back and to the side to expose the ground rail 6 WEAR ESD GROUND STRAP WHEN HANDLING PCB ...

Page 4: ... from power interface cable to the ground rail 3 Connect the power interface cable to the TB1 connector 4 Connect the power cable from the UEC to the plug on the PCB of the power interface cable 5 Move the board to the UEC back and install the four screws to secure it in place WIRING THE TOP COVER TO THE UEC 4800 1 2 INTERFACE CABLE 5 WEAR ESD GROUND STRAP WHEN HANDLING PCB 3 POWER INTERFACE CABLE...

Page 5: ...1 Kit 1 Install the front panel back in to the board on the UEC secure tightly 2 Install the top cover assembly to the UEC and reinstall the eight screws that hold the cover in place making sure not to pinch the wires coming out of the back 3 Install the two screws that hold the front panel in place WEAR ESD GROUND STRAP WHEN HANDLING PCB 1 2 3 ...

Page 6: ... UEC black wire to COM upper IN COM red wire to LS1 IN6 white wire to RESET IN3 green wire to work A IN4 and yellow wire to work B IN5 3 Connect the red fork with the two blue wires to the lower COM and the other red fork and the black wire to the top COM Install male bullet 26376 into the bullet connector on the blue wire Bundle wires zip tie and reinstall the I O cover WEAR ESD GROUND STRAP WHEN...

Page 7: ...he UEC PFB serial cable to the Profibus Slave Card and tighten the two screws on the connector You will need to set the two pots of the Profibus Slave Card Set MSD to zero and set LSD to eight WEAR ESD GROUND STRAP WHEN HANDLING PCB PFB SERIAL CABLE PROFIBUS SLAVE CARD Revision History Revision Date 11 04 2013 Document Change Log Initial Release ...

Page 8: ...MEXICO SA DE CV 10000 SE PINE STREET AVE CRISTOBAL COLON 14529 PORTLAND OREGON 97216 CHIHUAHUA CHIHUAHUA 31125 PHONE 503 254 6600 MEXICO TOLL FREE 1 800 852 1368 PHONE 01 614 380 1010 FAX 01 614 380 1019 LIT MAN175 REV 07 2020 PRINTED IN USA 2020 AIMCO ...