AHCTS Series User’s Guide
DESCRIPTION OF FUNCTIONS 12
DESCRIPTION OF FUNCTIONS
The following is a description of the standard features of the Auditor product line.
O
PERATING
M
ODES
Peak, 1st Peak or Track will show on the display. Press the Œ key to toggle them.
Peak
Recommended operating mode for stall tools.
Displays and retains the maximum torque exerted by the tool, as occurs when operating
the wrench in the tightening direction. The Peak Mode is used for all power tools and dial
wrenches.
1st Peak
Detects the “first peak” of torque exerted by the tool, capturing the initial torque as occurs
when the torque wrench cams over. First Peak is used primarily for Click Torque
Wrenches and cam over screwdrivers.
Track
Displays torque as it is being applied to the transducer. Track mode is used primarily for
verifying calibration of the unit.
E
NGINEERING
U
NITS
Shows the current engineering units. Press the
key to cycle through the eight
possible choices: Kgf m, KgfCm, gfCm, cNm, Nm, FT LB, IN LB, IN OZ.
F
ULL
S
CALE
Shows the Full-Scale value of the Torque Shaft. This is not an adjustable value.
L
OW
L
IMIT
Use the Low Limit setting to visually flag the operator when a reading fails to reach a
desired minimum value. A small down arrow will appear on the screen if a peak is
captured below the limit setting.
The limit is adjusted by using the navigation buttons to set the first four digits to the
desired value. The fifth digit is used to select the decimal point position. The Up and
Down buttons under the “Soft” button
Change
will change the value from 0-9. Pressing
the “soft”
DIG
will scroll through the digit positions. When the correct value is entered,
pressing the
ENT
button will return you to the menu system.