6
SPECIFICATIONS
Environmental
•
Operating Temperature: 0°C to 32°C
•
Storage Temperature: 0°C to 65°C
•
Humidity:
o
5% to 90% RH, Non-Condensing, for temperatures 0°C to 40°C
o
5% to 60% RH, Non-Condensing, for temperatures 0°C to 65°C
•
Maximum Altitude of Operation: 3000m
•
Maximum decibel level: 73 dB(A)
Electrical
•
Motor Type: BLDC
o
Motor Phase Voltage: 160 Volts Pulse DC @ Controller Supply
Voltage of 120 RMS, or 320 Volts Pulse DC @ Controller Supply
Voltage of 230 RMS
•
Duty Cycle: The nutrunner tools are intended for intermittent operation with a
recommended maximum duty cycle of 25% at 80% of maximum torque capacity on a
standard B-joint application. Note: Actual maximum duty cycles are dependent upon
several factors, including ambient temperature, tool selection, joint conditions, fastener
length, and tool programming strategies. For optimum duty cycle determinations,
please contact your AcraDyne sales representative.
Physical
•
2.7 lbs/1.2 kg – 3.2 lbs/1.5 kg
Performance
•
Torque range: 14 – 55 Nm
•
Speed Range: 394 – 1,750 RPM