background image

3

OPERATIONS

1. Connect tool cable to the iEC controller and the tool:

 

The tool cable has curved alignment tabs and slots built into 
the connectors at each end to ensure proper alignment and 
connection with the tool and controller.

Make sure that power is not turned on at the controller 

before making any connections.

 Align the female connector 

on the cable with the male connector on the tool and insert 
the cable onto the tool, then slide the connector nut onto 
the threads on the cable and turn clockwise until hand-tight.

Align the male connector tab on the other end of the tool 
cable with the female slot on the controller and insert the 
cable into the connector, then slide the metal outer cover 
onto the connection threads on the controller and turn 
clockwise until hand-tight.

2. Multifunction Button Operation: 

The tool will flash all LED lights three times when power is 
first turned on at the controller.  After the controller finishes 

initializing and displays a target toque value, the multifunction 
button (MFB) is used to toggle the tool from clockwise mode 
(FWD) to counter-clockwise operation mode (REV). The MFB 
is the small button above the trigger.  

The tool will initially start in clockwise mode and will have 
no LED lights turned on. If the trigger is pressed, the tool 
will turn on the blue LED meaning the tightening operation 

is underway. Pressing the MFB will cause the tool to flash 

yellow and red LED lights.  Pressing the MFB again will 
switch the tool back FWD mode and will indicate this with no 
LED lights turned on.

3. Start Lever Operation:

To start the tool, depress the start lever. Blue LED lights 
will be displayed while tightening a bolt. The tool will stop 
automatically when it senses its target torque value or if 

no torque is sensed in a specified time period. After a cycle 

is complete, the tool will display green LED lights for a 
success, or red LED lights for failure to reach torque/angle.

A complete tool system consists of the following items:

Light Ring Light Assignment

The Buzzer and Multi-Function Button are programmable in the 
DSP Menu of ToolWare.

Light Color

Meaning

Green Solid

OK

Red Flashing

Torque Low

Red Solid

Torque High

Yellow Flashing

Angle Low

Yellow Solid

Angle High

Blue Solid

Tool In-Cycle/Tool Armed

Blue Flashing

P-Set Change thru MFB

All On Flashing

Tool in Disassembly

Buzzer

Bad Assembly/Tool in Disassembly/Power Up

iEC Controller

Power cord

Tool

Tool Cable

Start Lever

Multi Function Button

Square/Hex Drive

Status Lights

Cable Connection

Summary of Contents for AcraDyne AcraDrive 2000 Series

Page 1: ...10000 SE Pine St Portland OR 97216 800 852 1368 Fax 800 582 9015 www aimco global com AcraDrive Gen IV 2000 Series DC Pulse Nutrunners Operations Manual ...

Page 2: ... Stay alert watch what you are doing and use common sense when operating a power tool Do not use a power tool while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating power tools may result in serious personal injury b Use safety equipment Always wear eye protection Safety equipment such as dust mask non skid safety shoes hard hat or hearing...

Page 3: ...he trigger The tool will initially start in clockwise mode and will have no LED lights turned on If the trigger is pressed the tool will turn on the blue LED meaning the tightening operation is underway Pressing the MFB will cause the tool to flash yellow and red LED lights Pressing the MFB again will switch the tool back FWD mode and will indicate this with no LED lights turned on 3 Start Lever O...

Page 4: ...s Gen 4c 1 Index Part Number Number Description Qty AEP4P22030AV AEP4P22050AV DC PULSE PISTOL TOOL EXPLODED VIEW PARTS LIST FOR REFERENCE ONLY 3 O RINGS LUBRICATE WITH O RING LUBE ASSEMBLY INSTRUCTIONS 1 GEARS SPLINES LUBRICATE WITH DOW CORNING MOLYKOTE BR2 PLUS GREASE 2 BEARINGS LUBRICATE WITH CHEVRON SR1 GREASE SUB ASSEMBLY 37 6 3 4 6 6 16 17 6 6 TIGHTEN TO 90Nm 66 FT LBS APPLY LOCTITE 243 BLUE ...

Page 5: ... Supply Voltage of 230 RMS Duty Cycle The Nutrunner tools are intended for intermittent operation with recommendedmaximum duty cycles not to exceed 33 Note actual maximum duty cycles are dependant upon several factors including ambient temperature tool selection joint conditions fastening parameter programming and different applications and strategies For optimum duty cycle determination please co...

Page 6: ...6 NOTES ...

Page 7: ......

Page 8: ...DE MEXICO SA DE CV 10000 SE PINE STREET AVE CRISTOBAL COLON 14529 PORTLAND OREGON 97216 CHIHUAHUA CHIHUAHUA 31125 PHONE 503 254 6600 MEXICO TOLL FREE 1 800 852 1368 PHONE 01 614 380 1010 FAX 01 614 380 1019 LIT MAN378 REV 11 2021 PRINTED IN USA 2021 ...

Reviews: