32
The Status of a Power Output may assume different values:
OK
SC
Short cut
OPEN
Open circuit
HTEMP
High temperature
OVERCUR
Over current
UNVOLT
Under voltage
OVERVOLT
Over voltage
You may use the two associated channels as any other channel. For example, if you wish to turn an Icon ON
on the display in case of a shortcut:
Here down an example shows how power out supervisor works.
At ON instant the output is activated. During the time T1, the output can source an inrush current higher
than user set value: the PDM does not check the overcurrent but only the Short circuit.