Release 1.04
17
Obscuring time
Obscuring time function allows you to decide whether to
capture split times or not. The obscuring time is a period
during which the Infrared receiver, after having acquired
lap/split marker, is “blind” and cannot detect markers. If you
do not wish to capture split times on a track where more
than one transmitter is positioned, please set the obscuring
time to a value of about 5 seconds lower than the track best
lap time. If, on the contrary, you wish to capture split times,
please set these parameters to a low value: the minimum
value the instrument accepts is 3, while the maximum is 180.
If you want to set obscuring time, please:
•
select obscuring time function in the first list.
•
use
“DEC-“,
and
“INC+”
buttons to set digit
numbers,
“OK”
button to save changes and
“CANC”
to discard changes.
Here follows three examples of Obscuring time configuration.