LCU-ONE Analog

User Manual

Release 1.02

 

1 2

3.2.3 – The keyboard 

On the left of the window are some buttons: 

  “Restore default lambda settings”: allows the user to restore default settings 

on 

LCU-ONE Analog

  “Transmit lambda configuration”: allows the user to transmit the configuration 

to the device 

  “Read Lambda configuration”: reads the configuration from the connected 

device 

  “UpgradeFirmware”: allows the user to upgrade the firmware of its device. 

Bottom central are these buttons: 

  “Save Lambda settings”: allows the user to export Lambda configuration 

  “Load lambda settings”: allows the user to import a Lambda configuration and 

transmit it to the device 

In the lower part of the window are thrre buttons: 

  “Select language”: allows the user to change the language 

  “OK”: allows the user to save the set parameters 

  “Exit”: allows the user to quit discarding changes. 

1 0

3.2.4 – Informative panels 

On top left of the software main window a series of panels shows the characteristics of 
the 

LCU-ONE Analog

 connected to the PC. These panels are different depending if the 

device is connected or not. 
Here below you see (left) the panels with the controller connected to the Pc and (right) 
the same panels with the controller not connected to the PC. 

 

 

  Connected to: PC serial port 

 Device type: 

LCU-ONE Analog

 

(controller has been recognised) 

  Device ID number: univocal serial 

number of the device 

  Firmware Version: firmware version 

installed on the device. 

If LCU-ONE Analog is not 
correctly connected to the Pc or if 
it is not connected at all, the 
system shows a “not connected” 
message and all information 
concerning the controller are set 
on N.D. (Not available) 

www.aim-sportline.com

 

11

Summary of Contents for LCU-ONE

Page 1: ...LCU ONE Analog User manual Release 1 02 AiM Infotech...

Page 2: ...guration 4 3 2 LCU ONE Analog custom configuration 7 3 2 1 Preliminary operation 8 3 2 2 Configuring Lambda controller 8 3 2 3 The keyboard 11 3 2 4 Informative panels 11 3 2 5 The analog output graph...

Page 3: ...ut gasoline for example it needs 14 57 parts of air to completely burn a part of gasoline obtaining Lambda value 1 read by the probe LCU ONE controller can detect lambda values in a range of 0 65 to 1...

Page 4: ...of at least 10 to avoid liquid condensation stuff to come in contact with the probe polluting it Once the probe is installed pay attention not to let the cable pass near to excessive heat sources the...

Page 5: ...dard is possible only if calibration curve default points 1 95 0 65 and 4 8 1 6 have not been modified To configure LCU ONE Analog with Race Studio Configuration follow this procedure run the software...

Page 6: ...e probe configuration panel that appears bottom left of channel layer highlighted in the image below Activate the drop down menu pressing the arrow button circled in the image above and select the fue...

Page 7: ...se and only in case its stoichiometric value is known press the button Add custom value and the window here below appears Insert the new value and the test to match Press Add new item to the list butt...

Page 8: ...1 00 07 or later To configure LCU ONE Analog run the software The following window appears This is software main window It is made up of two layers Lambda controller configurator it shows analog outpu...

Page 9: ...download latest release and follow carefully this procedure connect LCU ONE Analog to the PC read logger firmware version written in the case on the left of the central graph press Upgrade Firmware bu...

Page 10: ...in case its Stoichiometric value is known press Add custom value button and the window shown below appears Fill in the window with Multiplier value and related legend Press Add new item to list value...

Page 11: ...ured button placed on the left of the cases indicates the colour of this value on the central graph In the example the value is showed in light blue Once decided which values to show just fill in the...

Page 12: ...r to change the language OK allows the user to save the set parameters Exit allows the user to quit discarding changes 1 03 2 4 Informative panels On top left of the software main window a series of p...

Page 13: ...ndence of the measured Lambda values Graph colours are customizable Pressing Colour options button the window shown below appears Pressing each button a colour panel will appear showing all the availa...

Page 14: ...lease 1 02 3Chapter 4 Online values from Lambda controller This panel shows controller status The user is only allowed to set Lambda AFR and temperature unit of measure for the values shown in this pa...

Page 15: ...nd technical drawings 6 A Part number of LCU ONE Analog Complete kit with cable for MyChron3 XGLog X08LCU04XG Complete kit with cable for MyChron3 Plus Gold Auto Moto X08LCU04PG Lambda Probe Bosch LSU...

Page 16: ...LCU ONE Analog User Manual Release 1 02 www aim sportline com 15...

Reviews: