8. Appendix
ANET429-x Users Manual
54
8.2.5 Technical Data for the Rugged Variant
Following only the differences
between the ‘standard’ and the ‘rugged’ variant are
described.
Connectors:
LEMO Power and Control Connector
Power Input, Emergency-Reset, Power-Up Control
LEMO order number for customized cable:
Manufacturer: Lemo Order Number: FGG.0B.305.CLAD52Z
Manufacturer: Lemo Order Number: GMA.0B.045.DN
(connector and cable protection)
15 pol. high density DSUB, female
- Trigger IN and OUT
- Discrete-I/O
- IRIG-IN and IRIG-OUT
26 pol. high density DSUB, female
- ARINC429 Channel (1-12) signals
USB Type-A connector
RJ45 Ethernet Connector (female)
Voltage Supply
Input Voltage Range
see product label on module: V
IN
: 9…36V
DC
or
18…50 V
DC
Power Consumption
Stand by: PIN = ≤200mW
Operational (IDLE):
PIN = ~4,9W 12/16 channel
PIN = ~4W
8 channel
PIN = ~3,3W 4 channel
- Operational (low speed, with load):
PIN = ~6W
12/16 channel
PIN = ~5W
8 channel
PIN = ~4W
4 channel
Dimensions
218mm x 140mm x 55m (length x width x height, without
connectors)
Protection class
housing
IP67
Weight
~2200g
Summary of Contents for ANET42
Page 2: ......
Page 6: ...ANET429 x Users Manual iv THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 14: ...2 Installation ANET429 x Users Manual 4 Figure 2 1 Front panel Figure 2 2 Back panel...
Page 20: ...2 Installation ANET429 x Users Manual 10 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 34: ...3 Getting started ANET429 x Users Manual 24 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 52: ...6 FREQUENTLY ASKED QUESTIONS ANET429 x Users Manual 42 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 66: ...8 Appendix ANET429 x Users Manual 56 THIS PAGE IS INTENTIONALLY LEFT BLANK...