![Aigis Mechtronics MLA2DN25IR Installation And Operating Instructions Manual Download Page 17](http://html1.mh-extra.com/html/aigis-mechtronics/mla2dn25ir/mla2dn25ir_installation-and-operating-instructions-manual_2871469017.webp)
17
Figure 16 IR Board Adjustment
Figure 15 Desiccant Installation
8
DESICCANT INSTALLATION
Attach Desiccant To
Either Surface Using adhesive
Pad Supplied in Kit.
Keep Desiccant
Sealed in Plastic Bag
Until Ready For Installation.
9
IR BOARD ADJUSTMENT
9.1 User Adjustments
9.1.1 Light sensor sensitivity
SENSE Adjustment - turn CCW increases sensitivity.
To adjust for daytime setup - turn CCW until STATUS led (red) turns off.
9.1.2 Narrow Beam Intensity
NARROW adjustment - turn CW to increase intensity
9.1.3 Wide Beam Intensity
WIDE adjustment - turn CW to increase intensity
9.1.4 Always On
ALWAYS ON setting - Put Dip Switch 3 in the ON Position.
9.1.5 Time out
Time out Adjustment - Put dip switch 4 in the ON position (about 30
seconds delay).
Notes:
1.
Dip switch position 1 + 2 are for future options and should always be in
the OFF position.
2.
Connector 24V1(2 pin connector) and 24V2 (2 pin connector is used for
24V AC INPUT. Either pin on 24V1 is used for one leg of the 24VAC and
either pin on 24V2 is used for the other leg.
IR Board Adjustment Location
See Detail A
DETAIL A
Green, Power On
Light Sensor Adjustment
Red, Led Status On
Narrow Led Adjustment
Wide Led Adjustment
Dipswitch Block